摘要
An Ag/AgCl electrode used as a corrosion sensor in a reinforced concrete structure is considered as having good application prospect. However, its performance under complex conditions, such as dry-wet cycle condition, is not affirmed. In the current study, the performance of Ag/AgCl as chloride selective electrode in mortar exposed to dry-wet cycle condition was investigated. A simple Ag/AgCl electrode was prepared and fabricated by electrochemical anodization. These Ag/AgCl electrodes were embedded into a mortar specimen with temperature sensors, humidity sensors and anode ladder monitoring system (ALS). After 28 d curing time, the upper surface of mortar specimen was wetted (with 5% NaCl solution) and dried regularly. The obtained results indicate that Ag/AgCl electrode responds to the ingress of chloride ion, sensitively. The chloride ion concentration variation can be reflected by the potential trend. Furthermore, the balance potential of Ag/AgCl electrodes is influenced by dry-wet cycles. Compared with ALS, it demonstrates that Ag/AgCl electrodes are more sensitive to chloride. The research provides the key element for the specific application of Ag/AgCl electrode for corrosion monitoring in the future.
引用
收藏
页数:14
相关论文
共 41 条
  • [1] Connecting to Concrete: Wireless Monitoring of Chloride ions in Concrete structures
    Abbas, Yawar
    ten Have, Bas
    Hoekstra, Gerrit I.
    Douma, Arjan
    de Bruijn, Douwe
    Olthuis, Wouter
    van den Berg, Albert
    [J]. EUROSENSORS 2015, 2015, 120 : 965 - 968
  • [2] Potentiometric determination of the chloride ion activity in cement based materials
    Angst, Ueli
    Elsener, Bernhard
    Larsen, Claus K.
    Vennesland, Oystein
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (03) : 561 - 573
  • [3] Monitoring chloride concentrations in hardened cement pastes using ion selective electrodes
    Atkins, CP
    Scantlebury, JD
    Nedwell, PJ
    Blatch, SP
    [J]. CEMENT AND CONCRETE RESEARCH, 1996, 26 (02) : 319 - 324
  • [4] Influence of the incorporation of recycled coarse aggregate on water absorption and chloride penetration into concrete
    Bao, Jiuwen
    Li, Shuguo
    Zhang, Peng
    Ding, Xiaoya
    Xue, Shanbin
    Cui, Yifei
    Zhao, Tiejun
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2020, 239
  • [5] STUDIES ON THE HYDROLYSIS OF METAL IONS .30. A CRITICAL SURVEY OF THE SOLUBILITY EQUILIBRIA OF AG2O
    BIEDERMANN, G
    SILLEN, LG
    [J]. ACTA CHEMICA SCANDINAVICA, 1960, 14 (03): : 717 - 725
  • [6] An improved approach for fabricating Ag/AgCl reference electrodes
    Brewer, Paul J.
    Leese, Rebecca J.
    Brown, Richard J. C.
    [J]. ELECTROCHIMICA ACTA, 2012, 71 : 252 - 257
  • [7] Embeddable Ag/AgCl sensors for in-situ monitoring chloride contents in concrete
    ClimentLlorca, MA
    ViqueiraPerez, E
    LopezAtalaya, MM
    [J]. CEMENT AND CONCRETE RESEARCH, 1996, 26 (08) : 1157 - 1161
  • [8] Determination of the selectivity coefficient of a chloride ion selective electrode in alkaline media simulating the cement paste pore solution
    de Vera, G.
    Climent, M. A.
    Anton, C.
    Hidalgo, A.
    Andrade, C.
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2010, 639 (1-2) : 43 - 49
  • [9] In situ measurement of Cl- concentrations and pH at the reinforcing steel/concrete interface by combination sensors
    Du, Rong-Gui
    Hu, Rong-Gang
    Huang, Ruo-Shuang
    Lin, Chang-Jian
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (09) : 3179 - 3185
  • [10] Development of an embeddable sensor to monitor the corrosion process of new and existing reinforced concrete structures
    Duffo, Gustavo S.
    Farina, Silvia B.
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (08) : 2746 - 2751