Radiation properties of Turkish light source facility TURKAY

被引:2
|
作者
Nergiz, Zafer [1 ]
机构
[1] Nigde Univ, Fac Arts Sci, Dept Phys, TR-51200 Nigde, Turkey
关键词
TURKAY; Light source; Undulator; Brilliance; UNDULATOR;
D O I
10.1016/j.nima.2015.05.068
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The synchrotron light source TURKAY, which is one of the sub-project of Turkish Accelerator Center (TAC), has been supported by Ministry of Development of Turkey since 2006. The facility is designed to generate synchrotron radiation (SR) in range 0.01-60 keV from a 3 GeV storage ring with a beam emittance of 0.51 nm rad. Synchrotron radiation will be produced from the bending magnets and insertion devices in the storage ring. In this paper design studies for possible devices to produce synchrotron radiation and radiation properties of these devices with TURKAY storage ring parameters are presented. (C) 2015 Elsevier EN. All rights reserved
引用
收藏
页码:140 / 143
页数:4
相关论文
共 50 条
  • [31] Permanent magnet wigglers for reducing the emittance of the Petra III synchrotron radiation source
    A. M. Batrakov
    P. V. Vagin
    P. D. Vobly
    D. S. Gurov
    N. I. Zubkov
    I. V. Ilyin
    A. B. Ogurtsov
    M. Tischer
    A. V. Utkin
    N. G. Khavin
    M. A. Kholopov
    D. S. Shichkov
    Journal of Surface Investigation. X-ray, Synchrotron and Neutron Techniques, 2011, 5 : 1038 - 1044
  • [32] Permanent magnet wigglers for reducing the emittance of the Petra III synchrotron radiation source
    Batrakov, A. M.
    Vagin, P. V.
    Vobly, P. D.
    Gurov, D. S.
    Zubkov, N. I.
    Ilyin, I. V.
    Ogurtsov, A. B.
    Tischer, M.
    Utkin, A. V.
    Khavin, N. G.
    Kholopov, M. A.
    Shichkov, D. S.
    JOURNAL OF SURFACE INVESTIGATION-X-RAY SYNCHROTRON AND NEUTRON TECHNIQUES, 2011, 5 (06) : 1038 - 1044
  • [33] Lithography Light Source Fault Detection
    Graham, Matthew
    Pantel, Erica
    Nelissen, Patrick
    Moen, Jeffrey
    Tincu, Eduard
    Dunstan, Wayne
    Brown, Daniel
    OPTICAL MICROLITHOGRAPHY XXIII, 2010, 7640
  • [34] Fluorescence microscope light source stability
    Firas Mubaid
    Daniel Kaufman
    Tse-Luen Wee
    Dong-Son Nguyen-Huu
    David Young
    Maria Anghelopoulou
    Claire M. Brown
    Histochemistry and Cell Biology, 2019, 151 : 357 - 366
  • [35] Laparoscopic light source skin burn
    Hamdi, Jamal T.
    JOURNAL OF SURGICAL CASE REPORTS, 2024, 2024 (03):
  • [36] Spectral properties of bi-harmonic undulator radiation
    Mishra, G.
    Gehlot, Mona
    Hussain, Jeeva Khan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 603 (03) : 495 - 503
  • [37] Fluorescence microscope light source stability
    Mubaid, Firas
    Kaufman, Daniel
    Wee, Tse-Luen
    Dong-Son Nguyen-Huu
    Young, David
    Anghelopoulou, Maria
    Brown, Claire M.
    HISTOCHEMISTRY AND CELL BIOLOGY, 2019, 151 (04) : 357 - 366
  • [38] Insertion device development for a broad range of radiation properties
    Couprie, M. E.
    11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [39] Terahertz radiation source using a high-power industrial electron linear accelerator
    Kalkal, Yashvir
    Kumar, Vinit
    PRAMANA-JOURNAL OF PHYSICS, 2017, 88 (04):
  • [40] Light Source for Scanning Method of Size-of-Source Effect Measurement
    Achmadi, Aditya
    Juliastuti, Endang
    Handojo, Andrianto
    Zaid, Ghufron
    Wiriadinata, Hidayat
    Park, Seung-Nam
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2015, 36 (12) : 3330 - 3340