Graphene based highly sensitive refractive index sensor using double split ring resonator metasurface

被引:23
|
作者
Patel, Shobhit K. [1 ,2 ]
Solanki, Nilesh [1 ]
Charola, Shreyas [1 ,3 ]
Parmar, Juveriya [1 ,4 ]
Zakaria, Rozalina [5 ]
Faragallah, Osama S. [6 ]
Eid, Mahmoud M. A. [7 ]
Rashed, Ahmed Nabih Zaki [8 ]
机构
[1] Marwadi Univ, Dept Elect & Commun Engn, Rajkot 360003, Gujarat, India
[2] Marwadi Univ, Dept Comp Engn AI & Big Data, Rajkot 360003, Gujarat, India
[3] Marwadi Univ, Dept Informat & Commun Technol, Rajkot, Gujarat, India
[4] Marwadi Univ, Dept Phys, Rajkot, Gujarat, India
[5] Univ Malaya, Fac Sci, Photon Res Ctr, Kaula Lampur, Malaysia
[6] Taif Univ, Coll Comp & Informat Technol, Dept Informat Technol, POB 11099, At Taif 21944, Saudi Arabia
[7] Taif Univ, Coll Engn, Dept Elect Engn, POB 11099, At Taif 21944, Saudi Arabia
[8] Menoufia Univ, Fac Elect Engn, Elect & Elect Commun Engn Dept, Menoufia 32951, Egypt
关键词
Sensor; Refractive index; Graphene; Sensitivity; Metasurface; SURFACE-PLASMON RESONANCE; FIBER; PERFORMANCE; BIOSENSORS;
D O I
10.1007/s11082-022-03600-3
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A micrometer highly sensitive refractive index sensor comprising of double split ring metallic resonator placed above graphene layer is proposed. The sensitivity of the refractive index sensor is measured for hemoglobin biomolecule concentrations. The sensitivity of 5000 nm/RIU (Refractive Index Unit) over hemoglobin biomolecule with a different refractive index ranging from 1.34 to 1.43 are analyzed. A numerical investigation is performed between wavelength range from 55 mu m to 95 mu m to measure the sensing performance of the sensor. The absorption response is analyzed for change in thickness of double split-ring resonator metasurface, substrate thickness, and ground plane thickness In addition that absorption response is also observed with the change in chemical potential (mu(c)) of graphene and with different angles of incidence. The absorption response in the structure in term of the electric field with four different wavelengths are also presented. The comparative analysis with previously published structures is also presented in this paper. The proposed refractive index sensor structure is used to sense the hemoglobin biomolecules have better performance in terms of sensitivity compared to all the other designs. Due to its simple structure and easy fabrication steps, the refractive index sensor could be a potential device to be used in medical and diagnostic applications.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Graphene based highly sensitive refractive index sensor using double split ring resonator metasurface
    Shobhit K. Patel
    Nilesh Solanki
    Shreyas Charola
    Juveriya Parmar
    Rozalina Zakaria
    Osama S. Faragallah
    Mahmoud M. A. Eid
    Ahmed Nabih Zaki Rashed
    Optical and Quantum Electronics, 2022, 54
  • [2] Compact and Highly Sensitive Refractive Index Sensor Based on Embedded Double-Ring Resonator Using Vernier Effect
    Ma, Xiao Xia
    Zhao, Zhi Ying
    Yao, Hao
    Deng, Jia Yao
    Wu, Jie Yun
    Hu, Zhe Feng
    Chen, Kai Xin
    IEEE PHOTONICS JOURNAL, 2023, 15 (01):
  • [3] Highly Sensitive THz Refractive Index Sensor Based on Folded Split-Ring Metamaterial Graphene Resonators
    Mohammad-Reza Nickpay
    Mohammad Danaie
    Ali Shahzadi
    Plasmonics, 2022, 17 : 237 - 248
  • [4] Highly Sensitive THz Refractive Index Sensor Based on Folded Split-Ring Metamaterial Graphene Resonators
    Nickpay, Mohammad-Reza
    Danaie, Mohammad
    Shahzadi, Ali
    PLASMONICS, 2022, 17 (01) : 237 - 248
  • [5] High-sensitive refractive index sensors based on graphene ring metasurface
    Rastgordani, Amin
    Kashani, Zahra Ghattan
    OPTICS COMMUNICATIONS, 2020, 474
  • [6] A highly sensitive plasmonic refractive index sensor based on triangular resonator
    Al Mahmud, Rabiul
    Faruque, Md. Omar
    Sagor, Rakibul Hasan
    OPTICS COMMUNICATIONS, 2021, 483
  • [7] Highly Sensitive Graphene-Based Refractive Index Biosensor Using Gold Metasurface Array
    Patel, Shobhit K.
    Parmar, Juveriya
    Trivedi, Himitri
    Zakaria, Rozalina
    Truong Khang Nguyen
    Dhasarathan, Vigneswaran
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2020, 32 (12) : 681 - 684
  • [8] An Affordable, Customizable, and Highly Sensitive Metasurface-Based Refractive Index Sensor
    Ollanik, Adam J.
    Oguntoye, Isaac O.
    Hartfield, George Z.
    Escarra, Matthew D.
    2019 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2019,
  • [9] Graphene-Based Highly Sensitive Refractive Index Biosensors Using C-Shaped Metasurface
    Patel, Shobhit K.
    Parmar, Juveriya
    Kosta, Yogeshwar P.
    Charola, Shreyas
    Zakaria, Rozalina Binti
    Truong Khang Nguyen
    Dhasarathan, Vigneswaran
    IEEE SENSORS JOURNAL, 2020, 20 (12) : 6359 - 6366
  • [10] Tunable and highly sensitive graphene-based biosensor with circle/split ring resonator metasurface for sensing hemoglobin/urine biomolecules
    Parmar, Juveriya
    Patel, Shobhit K.
    PHYSICA B-CONDENSED MATTER, 2022, 624