Fast Radiofrequency Flip Angle Calibration by Bloch-Siegert Shift

被引:19
|
作者
Sacolick, Laura I. [1 ]
Sun, Ling [2 ]
Vogel, Mika W. [1 ]
Dixon, W. Thomas [3 ]
Hancu, Ileana [3 ]
机构
[1] Gen Elect Global Res, Imaging Technol Lab, D-85748 Garching, Germany
[2] GE Healthcare, Waukesha, WI USA
[3] Gen Elect Global Res, Imaging Technol Lab, Niskayuna, NY USA
关键词
B(1) mapping; RF calibration; flip angle; Bloch-Siegert shift; off-resonance; transmit gain; FIELD; MRI;
D O I
10.1002/mrm.22902
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In a recent work, we presented a novel method for B(1)(+) field mapping based on the Bloch-Siegert shift. Here, we apply this method to automated fast radiofrequency transmit gain calibration. Two off-resonance radiofrequency pulses were added to a slice-selective spin echo sequence. The off-resonance pulses induce a Bloch-Siegert phase shift in the acquired signal that is proportional to the square of the radiofrequency field magnitude B(1)(2). The signal is further spatially localized by a readout gradient, and the signal-weighted average B(1) field is calculated. This calibration from starting system transmit gain to average flip angle is used to calculate the transmit gain setting needed to produce a desired imaging sequence flip angle. A robust implementation is demonstrated with a scan time of 3 s. The Bloch-Siegert-based calibration was used to predict the transmit gain for a 90 degrees radiofrequency pulse and gave a flip angle of 88.6 +/- 3.42 degrees when tested in vivo in 32 volunteers. Magn Reson Med 66: 1333-1338, 2011. (C) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:1333 / 1338
页数:6
相关论文
共 47 条
  • [31] Linear Bloch-Siegert phase-encoded low-field MRI: RF coils, pulse sequence, and image reconstruction
    Srinivas, Sai Abitha
    Martin, Jonathan B.
    Vaughn, Christopher E.
    Grissom, William A.
    NMR IN BIOMEDICINE, 2024, 37 (12)
  • [32] SAR-reduced spin-echo-based Bloch-Siegert B1+ mapping: BS-SE-BURST
    Basse-Luesebrink, Thomas Christian
    Kampf, Thomas
    Fischer, Andre
    Sturm, Volker Joerg Friedrich
    Neumann, Daniel
    Koestler, Herbert
    Hahn, Dietbert
    Stoll, Guido
    Jakob, Peter Michael
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (02) : 529 - 536
  • [33] Robust 3D Bloch-Siegert based B1+mapping using multi-echo general linear modeling
    Corbin, Nadege
    Acosta-Cabronero, Julio
    Malik, Shaihan J.
    Callaghan, Martina F.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (06) : 2003 - 2015
  • [34] Accurate flip-angle calibration for 13C MRI
    Hancu, Ileana
    Watkins, Ronald
    Kohler, Susan J.
    Mallozzi, Richard P.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (01) : 128 - 133
  • [35] T1 measurements incorporating flip angle calibration and correction in vivo
    Wang, Jinghua
    Qiu, Maolin
    Kim, Hyeonjin
    Constable, R. Todd
    JOURNAL OF MAGNETIC RESONANCE, 2006, 182 (02) : 283 - 292
  • [36] A preparation pulse for fast steady state approach in Actual Flip angle Imaging
    Zampini, Marco Andrea
    Sijbers, Jan
    Verhoye, Marleen
    Garipov, Ruslan
    MEDICAL PHYSICS, 2024, 51 (01) : 306 - 318
  • [37] Flip-Angle Measurement by Magnetization Inversion: Calibration of Magnetization Nutation Angle in Hyperpolarized 3He Magnetic Resonance Imaging Lung Experiments
    Rivoire, J.
    Terekhov, M.
    Meise, F. M.
    Gast, K.
    Salhi, Z.
    Schreiber, L. M.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (02) : 399 - 408
  • [38] Fast Determination of Flip Angle and T1 in Hyperpolarized Gas MRI During a Single Breath-Hold
    Zhong, Jianping
    Ruan, Weiwei
    Han, Yeqing
    Sun, Xianping
    Ye, Chaohui
    Zhou, Xin
    SCIENTIFIC REPORTS, 2016, 6
  • [39] Hexagonal Gradient Scheme With RF Spoiling Improves Spoiling Performance for High-Flip-Angle Fast Gradient Echo Imaging
    Hess, Aaron T.
    Robson, Matthew D.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (03) : 1231 - 1237
  • [40] Flip Angle-Optimized Fast Dynamic T1 Mapping with a 3D Gradient Echo Sequence
    Dietrich, Olaf
    Freiermuth, Maximilian
    Willerding, Linus
    Reiser, Maximilian F.
    Peller, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (03) : 1158 - 1163