Development of a microfluidics biosensor for agarose-bead immobilized Escherichia coli bioreporter cells for arsenite detection in aqueous samples

被引:65
作者
Buffi, Nina [2 ]
Merulla, Davide [1 ]
Beutier, Julien [2 ]
Barbaud, Fanny [2 ]
Beggah, Siham [1 ]
van Lintel, Harald [2 ]
Renaud, Philippe [2 ]
van der Meer, Jan Roelof [1 ]
机构
[1] Univ Lausanne, Quartier UNIL Sorge, Dept Fundamental Microbiol, CH-1015 Lausanne, Switzerland
[2] Ecole Polytech Fed Lausanne, EPFL STI LMIS, Lab Microsyst Engn, CH-1015 Lausanne, Switzerland
基金
瑞士国家科学基金会;
关键词
BACTERIAL; GROUNDWATER; TOXICITY; BIOASSAY; HEALTH; WATER; KITS;
D O I
10.1039/c1lc20274j
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Contamination with arsenic is a recurring problem in both industrialized and developing countries. Drinking water supplies for large populations can have concentrations much higher than the permissible levels (for most European countries and the United States, 10 mu g As per L; elsewhere, 50 mu g As per L). Arsenic analysis requires high-end instruments, which are largely unavailable in developing countries. Bioassays based on genetically engineered bacteria have been proposed as suitable alternatives but such tests would profit from better standardization and direct incorporation into sensing devices. The goal of this work was to develop and test microfluidic devices in which bacterial bioreporters could be embedded, exposed and reporter signals detected, as a further step towards a complete miniaturized bacterial biosensor. The signal element in the biosensor is a nonpathogenic laboratory strain of Escherichia coli, which produces a variant of the green fluorescent protein after contact to arsenite and arsenate. E. coli bioreporter cells were encapsulated in agarose beads and incorporated into a microfluidic device where they were captured in 500 x 500 mu m(2) cages and exposed to aqueous samples containing arsenic. Cell-beads frozen at -20 degrees C in the microfluidic chip retained inducibility for up to a month and arsenic samples with 10 or 50 mu g L-1 could be reproducibly discriminated from the blank. In the 0-50 mu g L-1 range and with an exposure time of 200 minutes, the rate of signal increase was linearly proportional to the arsenic concentration. The time needed to reliably and reproducibly detect a concentration of 50 mu g L-1 was 75-120 minutes, and 120-180 minutes for a concentration of 10 mu g L-1
引用
收藏
页码:2369 / 2377
页数:9
相关论文
共 26 条
  • [1] Abernathy C, 1999, ARSENIC EXPOSURE HLT
  • [2] Arsenic contamination of groundwater and drinking water in Vietnam: A human health threat
    Berg, M
    Tran, HC
    Nguyen, TC
    Pham, HV
    Schertenleib, R
    Giger, W
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (13) : 2621 - 2626
  • [3] Integrated CMOS photodetectors and signal processing for very low-level chemical sensing with the bioluminescent bioreporter integrated circuit
    Bolton, EK
    Sayler, GS
    Nivens, DE
    Rochelle, JM
    Ripp, S
    Simpson, ML
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2002, 85 (1-2): : 179 - 185
  • [4] Development of bacteria-based bioassays for arsenic detection in natural waters
    Diesel, Elizabeth
    Schreiber, Madeline
    van der Meer, Jan Roelof
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (03) : 687 - 693
  • [5] Microbial whole-cell arrays
    Elad, Tal
    Lee, Jin Hyung
    Belkin, Shimshon
    Gu, Man Bock
    [J]. MICROBIAL BIOTECHNOLOGY, 2008, 1 (02): : 137 - 148
  • [6] Spatial and Temporal Variations of Groundwater Arsenic in South and Southeast Asia
    Fendorf, Scott
    Michael, Holly A.
    van Geen, Alexander
    [J]. SCIENCE, 2010, 328 (5982) : 1123 - 1127
  • [7] Alginate gel biochip for real-time monitoring of intracellular processes in bacterial and yeast cells
    Fesenko, DO
    Nasedkina, TV
    Chudinov, AV
    Prokopenko, DV
    Yurasov, RA
    Zasedatelev, AS
    [J]. MOLECULAR BIOLOGY, 2005, 39 (01) : 84 - 89
  • [8] HADEMHOSSEINI A, 2004, LAB CHIP, V4, P425
  • [9] On-chip culture system for observation of isolated individual cells
    Inoue, I
    Wakamoto, Y
    Moriguchi, H
    Okano, K
    Yasuda, K
    [J]. LAB ON A CHIP, 2001, 1 (01): : 50 - 55
  • [10] Arsenic: Occurrence, toxicity and speciation techniques
    Jain, CK
    Ali, I
    [J]. WATER RESEARCH, 2000, 34 (17) : 4304 - 4312