Micelle to solvent stacking of organic cations in micellar electrokinetic chromatography with sodium dodecyl sulfate

被引:35
|
作者
Quirino, Joselito P. [1 ,2 ]
Aranas, Agnes T. [1 ,2 ]
机构
[1] Univ Tasmania, Sch Chem, Australian Ctr Res Separat Sci ACROSS, Hobart, Tas 7001, Australia
[2] Ateneo Manila Univ, Loyola Sch, Sch Sci & Engn, Dept Chem, Quezon City 1108, Metro Manila, Philippines
基金
澳大利亚研究理事会;
关键词
Micellar electrokinetic chromatography; Drugs; Herbicides; Micelle to solvent stacking; Analyte focusing by micelle collapse; Sweeping; CAPILLARY-ZONE-ELECTROPHORESIS; ONLINE SAMPLE PRECONCENTRATION; DYNAMIC PH JUNCTION; SELECTIVE EXHAUSTIVE INJECTION; TRANSIENT ISOTACHOPHORESIS; SENSITIVITY ENHANCEMENT; COLLAPSE; DRUGS; CZE; SEPARATION;
D O I
10.1016/j.chroma.2011.08.028
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The on-line sample concentration technique, micelle to solvent stacking (MSS), was studied for small organic cations (quaternary ammonium herbicides, beta-blocker drugs, and tricyclic antidepressant drugs) in reversed migration micellar electrokinetic chromatography. Electrokinetic chromatography was carried out in fused silica capillaries with a background solution of sodium dodecyl sulfate (SDS) in a low pH phosphate buffer. MSS was performed using anionic SDS micelles in the sample solution for analyte transport and methanol or acetonitrile as organic solvent in the background solution for analyte effective electrophoretic mobility reversal. The solvent also allowed for the separation of the analyte test mixtures. A model for focusing and separation was developed and the mobility reversal that involved micelle collapse was experimentally verified. The effect of analyte retention factor was observed by changing the % organic solvent in the background solution or the concentration of SDS in the sample matrix. With an injection length of 31.9 cm (77% of effective capillary length) for the 7 test drugs, the LODs (S/N = 3) of 5-14 ng/mL were 101-346-fold better when compared to typical injection. The linearity (R(2), range = 0.025-0.8 mu g/mL), intraday and interday repeatability (%RSD, n = 10) were >= 0.988, <6.0% and <8.5%, respectively. In addition, analysis of spiked urine samples after 10-fold dilution with the sample matrix yielded LODs = 0.02-0.10 mu g/mL. These LODs are comparable to published electrophoretic methods that required off-line sample concentration. However, the practicality of the technique for more complex samples will rely on dedicated sample preparation schemes. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:7377 / 7383
页数:7
相关论文
共 50 条
  • [31] Methyl Chloroacetate as Extraction Solvent for Coupling Liquid-liquid Semimicroextraction with Micellar Electrokinetic Chromatography for the Separation of Neutral Compounds with Concentration Enhancement
    Tang Jing
    Zheng Sheng-Biao
    Zhu Jin-Kun
    Wang Tian-Lin
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2011, 32 (07): : 1488 - 1491
  • [33] Effect of organic modifiers on the capacity factor in micellar electrokinetic chromatography
    Shi, W
    Zhang, J
    Wang, L
    Zou, HF
    Zhang, YK
    CHINESE JOURNAL OF CHEMISTRY, 1997, 15 (02) : 144 - 153
  • [34] Comparison of microemulsion electrokinetic chromatography and solvent modified micellar electrokinetic chromatograph on rapid separation of heroin, amphetamine and their basic impurities
    Wen, Tao
    Zhao, Xia
    Luo, Guoan
    Wang, Jian
    Wang, Yiming
    Yao, Bo
    Zhao, Jiyuan
    Zhu, Jun
    Yu, Zhongshan
    TALANTA, 2007, 71 (02) : 854 - 860
  • [35] Micellar electrokinetic chromatography of organic and peroxide-based explosives
    Johns, Cameron
    Hutchinson, Joseph P.
    Guijt, Rosanne M.
    Hilder, Emily F.
    Haddad, Paul R.
    Macka, Mirek
    Nesterenko, Pavel N.
    Gaudry, Adam J.
    Dicinoski, Greg W.
    Breadmore, Michael C.
    ANALYTICA CHIMICA ACTA, 2015, 876 : 91 - 97
  • [36] A QUANTITATIVE STUDY ON THE EFFECT OF ORGANIC MODIFIERS IN MICELLAR ELECTROKINETIC CHROMATOGRAPHY
    CHEN, N
    TERABE, S
    ELECTROPHORESIS, 1995, 16 (11) : 2100 - 2103
  • [37] Stacking and separation of fluorescent derivatives of amino acids by micellar electrokinetic chromatography in the presence of poly(ethylene oxide)
    Chiu, Tai-Chia
    Chang, Huan-Tsung
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1146 (01) : 118 - 124
  • [38] A simple apparatus for electrokinetic removal of sodium dodecyl sulfate from protein digests
    Pandigamage, Pravinda
    Wilson, Richard
    Quirino, Joselito P.
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1628
  • [39] Chiral separation of polychlorinated biphenyls by micellar electrokinetic chromatography with sodium cholate
    Crego, AL
    Gonzalez, MJ
    Marina, ML
    ELECTROPHORESIS, 1998, 19 (12) : 2113 - 2118
  • [40] Stacking and separation of coproporphyrin isomers by acetonitrile-salt mixtures in micellar electrokinetic chromatography
    So, TSK
    Jia, L
    Huie, CW
    ELECTROPHORESIS, 2001, 22 (11) : 2159 - 2166