CT coronary angiography: Influence of different cardiac reconstruction intervals on image quality and diagnostic accuracy

被引:7
|
作者
Dewey, Marc [1 ]
Teige, Florian [1 ]
Rutsch, Wolfgang [2 ]
Schink, Tania [3 ]
Hamm, Bernd [1 ]
机构
[1] Univ Humberside, Inst Radiol, Charite Med Sch, D-10117 Berlin, Germany
[2] Univ Humberside, Dept Cardiol, Charite Med Sch, D-10117 Berlin, Germany
[3] Univ Humberside, Dept Med Biometry, Charite Med Sch, D-10117 Berlin, Germany
关键词
computed tomography; angiography; coronary vessels; sensitivity; cardiac; reconstruction;
D O I
10.1016/j.ejrad.2007.07.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively analyze image quality and diagnostic accuracy of different reconstruction intervals of coronary angiography using multislice computed tomography (MSCT). Materials and methods: For each of 47 patients, 10 ECG-gated MSCT reconstructions were generated throughout the RR interval from 0 to 90%, resulting in altogether 470 datasets. These datasets were randomly analyzed for image quality and accuracy and compared with conventional angiography. Statistical comparison of intervals was performed using nonparametric analysis for repeated measurements to account for clustering of arteries within patients. Results: Image reconstruction intervals centered at 80, 70, and 40% of the RR interval resulted (in that order) in the best overall image quality for all four main coronary vessels. Eighty percent reconstructions also yielded the highest diagnostic accuracy of all intervals. The combination of the three best intervals (80, 70, and 40%) significantly reduced the nondiagnostic rate as compared with 80% alone (p=0.005). However, the optimal reconstruction interval combination achieved significantly improved specificities and nondiagnostic rates (p < 0.05). The optimal combination consisted of 1.7 +/- 0.9 reconstruction intervals on average. In approximately half of the patients (49%, 23/47) a single reconstruction was optimal. In 18 (38%), 3 (6%), and 3 (6%) patients one, two, and three additional reconstruction intervals were required, respectively, to achieve optimal quality. In 28% of the patients the optimal combination consisted of reconstructions other than the three best intervals (80, 70, and 40%). Conclusion: Multiple image reconstruction intervals are essential to ensure high image quality and accuracy of CT coronary angiography. (c) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:92 / 99
页数:8
相关论文
共 50 条
  • [21] Radiation dose in cardiac CT angiography: protocols and image quality
    Oliveira, L. C. G.
    Gottlieb, I.
    Rizzi, P.
    Lopes, R. T.
    Kodlulovich, S.
    RADIATION PROTECTION DOSIMETRY, 2013, 155 (01) : 73 - 80
  • [22] The image quality and diagnostic performance of CT perfusion-derived CT angiography versus that of conventional CT angiography
    Zhou, Xiu-Zhi
    Lu, Kuan
    Zhai, Du-Chang
    Cui, Man-Man
    Liu, Yan
    Wang, Ting-Ting
    Shi, Dai
    Fan, Guo-Hua
    Ju, Sheng-Hong
    Cai, Wu
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (10) : 7294 - 7303
  • [23] Dose performance and image quality: Dual source CT versus single source CT in cardiac CT angiography
    Wang, Min
    Qi, Heng-Tao
    Wang, Xi-Ming
    Wang, Tao
    Chen, Jiu-Hong
    Liu, Cheng
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 72 (03) : 396 - 400
  • [24] Diagnostic Accuracy of Computed Tomography Angiography in Patients After Bypass Grafting Comparison With Invasive Coronary Angiography
    Weustink, Annick C.
    Nieman, Koen
    Pugliese, Fransesca
    Mollet, Nico R.
    Meijboom, Bob W.
    van Mieghem, Carlos
    ten Kate, Gert-Jan
    Cademartiri, Filippo
    Krestin, Gabriel P.
    de Feyter, Pim J.
    JACC-CARDIOVASCULAR IMAGING, 2009, 2 (07) : 816 - 824
  • [25] Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy
    Kim, Rihyeon
    Park, Eun-Ah
    Lee, Whal
    Chung, Jin Wook
    EUROPEAN RADIOLOGY, 2016, 26 (11) : 3802 - 3810
  • [26] Assessment of image quality and radiation dose in prospective ECG-triggered coronary CT angiography compared with retrospective ECG-gated coronary CT angiography
    Ko, Sung Min
    Kim, Na Ra
    Kim, Dong Hun
    Song, Meong Gun
    Kim, Jin Hwan
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 : 93 - 101
  • [27] Predictors of Image Quality in High-Pitch Coronary CT Angiography
    Stolzmann, Paul
    Goetti, Robert P.
    Maurovich-Horvat, Pal
    Hoffmann, Udo
    Flohr, Thomas G.
    Leschka, Sebastian
    Alkadhi, Hatem
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (04) : 851 - 858
  • [28] A comparison of reconstruction and viewing parameters on image quality and accuracy of stress myocardial CT perfusion
    Ghoshhajra, Brian B.
    Rogers, Ian S.
    Maurovich-Horvat, Pal
    Techasith, Tust
    Verdini, Daniel
    Sidhu, Manavjot S.
    Drzezga, Nicola K.
    Medina, Hector M.
    Blankstein, Ron
    Brady, Thomas J.
    Cury, Ricardo C.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2011, 5 (06) : 459 - 466
  • [29] Impact of PVCs noted during coronary calcium scan on image quality and accuracy in subsequent coronary dual-source CT angiography
    Eicher, Wolfgang
    Kau, Thomas
    Niedermayer, Martin
    Senft, Birgit
    Sinzig, Maria
    Strozyk, Birgit
    Hausegger, Klaus Armin
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (04) : 601 - 610
  • [30] Image fusion of coronary CT angiography and cardiac perfusion MRI: a pilot study
    Paul Stolzmann
    Hatem Alkadhi
    Hans Scheffel
    Anja Hennemuth
    Caroline Kuehnel
    Stephan Baumueller
    Sebastian Kozerke
    Volkmar Falk
    Borut Marincek
    Olivio F. Donati
    European Radiology, 2010, 20 : 1174 - 1179