Digital evaluation of the reproducibility of implant scanbody fit-an in vitro study

被引:103
作者
Stimmelmayr, Michael
Gueth, Jan-Frederik [1 ]
Erdelt, Kurt [1 ]
Edelhoff, Daniel [1 ]
Beuer, Florian [1 ]
机构
[1] Univ Munich, Dept Prosthodont, D-80336 Munich, Germany
关键词
Implants; Scanbodies; CAD/CAM; Impression; Model scanning; MICROBIAL FINDINGS; PERI-IMPLANT; IMPRESSIONS; COMPONENTS; ACCURACY;
D O I
10.1007/s00784-011-0564-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Dental restorations are increasingly manufactured by CAD/CAM systems. Currently, there are two alternatives for digitizing dental implants: direct intra-oral data capturing or indirect from a master cast, both with transfer caps (scanbodies). The aim of this study was the evaluation of the fit of the scanbodies and their ability of reposition. At the site of the first molars and canines, implants were placed bilaterally in a polymer lower arch model (original model), and an impression was taken for fabricating a stone cast (stone model). Ten white-light scans were obtained from the original and the stone model with the scanbodies in place. The scanbodies were retrieved after each scan and re-attached to the same implant or lab analogue. The first scan of the series served as control in both groups. The subsequent nine scans and control were superimposed using inspection software to identify the discrepancies of the four scanbodies in both experimental groups. The systematic error of digitizing the models was 13 mu m for the polymer and 5 mu m for the stone model. The mean discrepancy of the scanbodies was 39 mu m (+/- 58 mu m) on the original implants versus 11 mu m (+/- 17 mu m) on the lab analogues. The difference in scanbody discrepancy between original implants and lab analogues was statistically significant ( < 0.05, Mann-Whitney test). Scanbody discrepancy was higher on original implants than on lab analogues. Fit and reproducibility of the scanbodies on original implants should be improved to achieve higher accuracy of implant-supported CAD/CAM fabricated restorations.
引用
收藏
页码:851 / 856
页数:6
相关论文
共 28 条
  • [1] Al-Bakri I A, 2007, J Clin Dent, V18, P29
  • [2] Assuncao Wirley Goncalves, 2004, Implant Dent, V13, P358
  • [3] Augthun M, 1997, INT J ORAL MAX IMPL, V12, P106
  • [4] Balshi T J, 1996, Int J Oral Maxillofac Implants, V11, P660
  • [5] Digital dentistry: an overview of recent developments for CAD/CAM generated restorations
    Beuer, F.
    Schweiger, J.
    Edelhoff, D.
    [J]. BRITISH DENTAL JOURNAL, 2008, 204 (09) : 505 - 511
  • [6] Binon PP, 1996, INT J PROSTHODONT, V9, P511
  • [7] Binon PP, 2000, INT J ORAL MAX IMPL, V15, P76
  • [8] TIGHTENING CHARACTERISTICS FOR SCREWED JOINTS IN OSSEOINTEGRATED DENTAL IMPLANTS
    BURGUETE, RL
    JOHNS, RB
    KING, T
    PATTERSON, EA
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1994, 71 (06) : 592 - 599
  • [9] Carr A B, 1991, Int J Oral Maxillofac Implants, V6, P448
  • [10] Will digital impressions eliminate the current problems with conventional impressions?
    Christensen, Gordon J.
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2008, 139 (06) : 761 - 763