Respiratory mechanics during high-frequency oscillatory ventilation: a physical model and preterm infant study

被引:14
|
作者
Singh, Rachana [2 ]
Courtney, Sherry E. [3 ]
Weisner, Michael D. [4 ]
Habib, Robert H. [1 ]
机构
[1] Amer Univ Beirut, Med Ctr, Clin Res Inst, Outcomes Res Unit,Dept Internal Med, Beirut 11072020, Lebanon
[2] Baystate Med Ctr, Div Newborn Med, Springfield, MA USA
[3] SUNY Stony Brook, Med Ctr, Div Neonatol, Stony Brook, NY USA
[4] Equilibrated Bio Syst Inc, Smithtown, NY USA
关键词
mechanical ventilation; endotracheal tube leak; tracheal pressure monitoring; very low birth weight; UNCUFFED ENDOTRACHEAL-TUBES; PRESSURE; FUTURE;
D O I
10.1152/japplphysiol.01120.2011
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Singh R, Courtney SE, Weisner MD, Habib RH. Respiratory mechanics during high-frequency oscillatory ventilation: a physical model and preterm infant study. J Appl Physiol 112: 1105-1113, 2012. First published December 29, 2011; doi:10.1152/japplphysiol.01120.2011.- Accurate mechanics measurements during high-frequency oscillatory ventilation (HFOV) facilitate optimizing ventilator support settings. Yet, these are influenced substantially by endotracheal tube (ETT) contributions, which may dominate when leaks around uncuffed ETT are present. We hypothesized that 1) the effective removal of ETT leaks may be confirmed via direct comparison of measured vs. model-predicted mean intratracheal pressure [mPtr (meas) vs. mPtr (pred)], and 2) reproducible respiratory system resistance (Rrs) and compliance (Crs) may be derived from no-leak oscillatory Ptr and proximal flow. With the use of ETT test-lung models, proximal airway opening (Pao) and distal (Ptr) pressures and flows were measured during slow-cuff inflations until leaks are removed. These were repeated for combinations of HFOV settings [frequency, mean airway pressure (Paw), oscillation amplitudes (Delta P), and inspiratory time (%t(I))] and varying test-lung Crs. Results showed that leaks around the ETT will 1) systematically reduce the effective distending pressures and lung-delivered oscillatory volumes, and 2) derived mechanical properties are increasingly nonphysiologic as leaks worsen. Mean pressures were systematically reduced along the ventilator circuit and ETT (Paw > Pao > Ptr), even for no-leak conditions. ETT size-specific regression models were then derived for predicting mPtr based on mean Pao (mPao), Delta P, %t(I), and frequency. Next, in 10 of 11 studied preterm infants (0.77 +/- 0.24 kg), no-to-minimal leak was confirmed based on excellent agreement between mPtr (meas) and mPtr (pred), and consequently, their oscillatory respiratory mechanics were evaluated. Infant resistance at the proximal ETT (R-ETT; resistance airway opening = R-ETT + Rrs; P < 0.001) and ETT inertance (P = 0.014) increased significantly with increasing Delta n P (50%, 100%, and 150% baseline), whereas Rrs showed a modest, nonsignificant increase (P = 0.14), and Crs was essentially unchanged (P = 0.39). We conclude that verifying no-leak conditions is feasible by comparison of model-derived vs. distending mPtr (meas). This facilitated the reliable and accurate assessment of physiologic respiratory mechanical properties that can objectively guide ventilatory management of HFOV-treated preterm infants.
引用
收藏
页码:1105 / 1113
页数:9
相关论文
共 50 条
  • [31] HIGH-FREQUENCY OSCILLATORY VENTILATION IN PEDIATRIC RESPIRATORY-FAILURE
    ARNOLD, JH
    TRUOG, RD
    THOMPSON, JE
    FACKLER, JC
    CRITICAL CARE MEDICINE, 1993, 21 (02) : 272 - 278
  • [32] High-frequency oscillatory ventilation for acute respiratory distress syndrome
    Yildizdas, Dincer
    Yapicioglu, Hacer
    Bayram, Ibrahim
    Yilmaz, Levent
    Sertdemir, Yasar
    INDIAN JOURNAL OF PEDIATRICS, 2009, 76 (09): : 921 - 927
  • [33] Humidification during high-frequency oscillatory ventilation for adults: A bench study
    Chikata, Yusuke
    Imanaka, Hideaki
    Ueta, Masahiko
    Nishimura, Masaji
    MEDICAL SCIENCE MONITOR, 2010, 16 (12): : MT89 - MT93
  • [34] COMPARISON OF HIGH-FREQUENCY OSCILLATORY VENTILATION AND HIGH-FREQUENCY JET VENTILATION
    BOROS, SJ
    MAMMEL, MC
    HORCHER, P
    GORDON, MJ
    CLINICAL RESEARCH, 1987, 35 (01): : A240 - A240
  • [35] Effect of Volume Guarantee in Preterm Infants on High-Frequency Oscillatory Ventilation: A Pilot Study
    Enomoto, Masahiro
    Keszler, Martin
    Sakuma, Mio
    Kikuchi, Shin
    Katayama, Yoshinori
    Takei, Atsuko
    Ikegami, Hitoshi
    Minami, Hirotaka
    AMERICAN JOURNAL OF PERINATOLOGY, 2017, 34 (01) : 26 - 30
  • [36] SURFACTANT DISTRIBUTION DURING HIGH-FREQUENCY OSCILLATORY VENTILATION
    LOUDER, DS
    NULL, DM
    STRIBLEY, RF
    PEDIATRIC RESEARCH, 1995, 37 (04) : A340 - A340
  • [37] ATRIAL REFLEXES DURING HIGH-FREQUENCY OSCILLATORY VENTILATION
    REWA, G
    MAN, P
    KAPPAGODA, CT
    PROCEEDINGS OF THE SOCIETY FOR EXPERIMENTAL BIOLOGY AND MEDICINE, 1985, 180 (03): : 505 - 512
  • [38] Assessment of Dynamic Mechanical Properties of the Respiratory System During High-Frequency Oscillatory Ventilation
    Dellaca, Raffaele L.
    Zannin, Emanuela
    Ventura, Maria L.
    Sancini, Giulio
    Pedotti, Antonio
    Tagliabue, Paolo
    Miserocchi, Giuseppe
    CRITICAL CARE MEDICINE, 2013, 41 (11) : 2502 - 2511
  • [39] MECHANICAL RESPIRATORY SYSTEM INPUT IMPEDANCE DURING HIGH-FREQUENCY OSCILLATORY VENTILATION IN RABBITS
    SIPINKOVA, I
    KOLLER, EA
    BUESS, C
    KOHL, J
    CRITICAL CARE MEDICINE, 1994, 22 (09) : S66 - S70
  • [40] LUNG REFLEXES DURING HIGH-FREQUENCY OSCILLATORY VENTILATION
    KOHL, J
    KOLLER, EA
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1987, 408 (02): : S31 - S31