Respiratory mechanics during high-frequency oscillatory ventilation: a physical model and preterm infant study

被引:14
|
作者
Singh, Rachana [2 ]
Courtney, Sherry E. [3 ]
Weisner, Michael D. [4 ]
Habib, Robert H. [1 ]
机构
[1] Amer Univ Beirut, Med Ctr, Clin Res Inst, Outcomes Res Unit,Dept Internal Med, Beirut 11072020, Lebanon
[2] Baystate Med Ctr, Div Newborn Med, Springfield, MA USA
[3] SUNY Stony Brook, Med Ctr, Div Neonatol, Stony Brook, NY USA
[4] Equilibrated Bio Syst Inc, Smithtown, NY USA
关键词
mechanical ventilation; endotracheal tube leak; tracheal pressure monitoring; very low birth weight; UNCUFFED ENDOTRACHEAL-TUBES; PRESSURE; FUTURE;
D O I
10.1152/japplphysiol.01120.2011
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Singh R, Courtney SE, Weisner MD, Habib RH. Respiratory mechanics during high-frequency oscillatory ventilation: a physical model and preterm infant study. J Appl Physiol 112: 1105-1113, 2012. First published December 29, 2011; doi:10.1152/japplphysiol.01120.2011.- Accurate mechanics measurements during high-frequency oscillatory ventilation (HFOV) facilitate optimizing ventilator support settings. Yet, these are influenced substantially by endotracheal tube (ETT) contributions, which may dominate when leaks around uncuffed ETT are present. We hypothesized that 1) the effective removal of ETT leaks may be confirmed via direct comparison of measured vs. model-predicted mean intratracheal pressure [mPtr (meas) vs. mPtr (pred)], and 2) reproducible respiratory system resistance (Rrs) and compliance (Crs) may be derived from no-leak oscillatory Ptr and proximal flow. With the use of ETT test-lung models, proximal airway opening (Pao) and distal (Ptr) pressures and flows were measured during slow-cuff inflations until leaks are removed. These were repeated for combinations of HFOV settings [frequency, mean airway pressure (Paw), oscillation amplitudes (Delta P), and inspiratory time (%t(I))] and varying test-lung Crs. Results showed that leaks around the ETT will 1) systematically reduce the effective distending pressures and lung-delivered oscillatory volumes, and 2) derived mechanical properties are increasingly nonphysiologic as leaks worsen. Mean pressures were systematically reduced along the ventilator circuit and ETT (Paw > Pao > Ptr), even for no-leak conditions. ETT size-specific regression models were then derived for predicting mPtr based on mean Pao (mPao), Delta P, %t(I), and frequency. Next, in 10 of 11 studied preterm infants (0.77 +/- 0.24 kg), no-to-minimal leak was confirmed based on excellent agreement between mPtr (meas) and mPtr (pred), and consequently, their oscillatory respiratory mechanics were evaluated. Infant resistance at the proximal ETT (R-ETT; resistance airway opening = R-ETT + Rrs; P < 0.001) and ETT inertance (P = 0.014) increased significantly with increasing Delta n P (50%, 100%, and 150% baseline), whereas Rrs showed a modest, nonsignificant increase (P = 0.14), and Crs was essentially unchanged (P = 0.39). We conclude that verifying no-leak conditions is feasible by comparison of model-derived vs. distending mPtr (meas). This facilitated the reliable and accurate assessment of physiologic respiratory mechanical properties that can objectively guide ventilatory management of HFOV-treated preterm infants.
引用
收藏
页码:1105 / 1113
页数:9
相关论文
共 50 条
  • [1] Dependence of intrapulmonary pressure amplitudes on respiratory mechanics during high-frequency oscillatory ventilation in preterm lambs
    Pillow, JJ
    Sly, PD
    Hantos, Z
    Bates, JHT
    PEDIATRIC RESEARCH, 2002, 52 (04) : 538 - 544
  • [2] Dependence of intrapulmonary pressure amplitudes on respiratory mechanics during high-frequency oscillatory ventilation in preterm lambs
    Pillow J.J.
    Sly P.D.
    Hantos Z.
    Bates J.H.T.
    Pediatric Research, 2002, 52 (4) : 538 - 544
  • [3] MECHANICS OF THE RESPIRATORY SYSTEM DURING HIGH-FREQUENCY VENTILATION
    FREDBERG, JJ
    ALLEN, J
    TSUDA, A
    BOYNTON, B
    BANZETT, R
    BUTLER, J
    LEHR, J
    FRANTZ, ID
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1989, 33 : 39 - 45
  • [4] MECHANICS OF IN VITRO HIGH-FREQUENCY OSCILLATORY VENTILATION
    Wong, Ronald
    Deakers, Timothy
    Hotz, Justin
    Khemani, Robinder
    Ross, Patrick
    Newth, Christopher
    CRITICAL CARE MEDICINE, 2014, 42 (12)
  • [5] RESPIRATORY INPUT IMPEDANCE DURING HIGH-FREQUENCY OSCILLATORY VENTILATION
    NAVAJAS, D
    FARRE, R
    BRITISH JOURNAL OF ANAESTHESIA, 1989, 63 : S85 - S90
  • [6] Identification of the Model of the Respiratory System in High-frequency Oscillatory Ventilation
    Rozanek, Martin
    Kudrna, Petr
    Rozankova, Zuzana
    Roubik, Karel
    2015 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2015,
  • [7] PULMONARY MECHANICS IN PRETERM NEONATES WITH RESPIRATORY-FAILURE TREATED WITH HIGH-FREQUENCY OSCILLATORY VENTILATION COMPARED WITH CONVENTIONAL MECHANICAL VENTILATION
    ABBASI, S
    BHUTANI, VK
    SPITZER, AR
    FOX, WW
    PEDIATRICS, 1991, 87 (04) : 487 - 493
  • [8] Prophylactic high-frequency oscillatory ventilation in preterm infants
    Calvert, S
    ACTA PAEDIATRICA, 2002, 91 : 16 - 18
  • [9] Hemodynamic effects of high-frequency oscillatory ventilation in preterm neonates with respiratory distress syndrome
    Ayoub, Dalia
    Elmashad, Abdelrahman
    Rowisha, Mohamed
    Eltomey, Mohamed
    El Amrousy, Doaa
    PEDIATRIC PULMONOLOGY, 2021, 56 (02) : 424 - 432
  • [10] High-frequency oscillatory ventilation in neonatal RDS: initial volume optimization and respiratory mechanics
    Kalenga, M
    Battisti, O
    Francois, A
    Langhendries, JP
    Gerstmann, DR
    Bertrand, JM
    JOURNAL OF APPLIED PHYSIOLOGY, 1998, 84 (04) : 1174 - 1177