Placement of deep brain stimulator electrodes using real-time high-field interventional magnetic resonance imaging

被引:77
作者
Martin, AJ
Larson, PS
Ostrem, FL
Sootsman, WK
Talke, P
Weber, OM
Levesque, N
Myers, J
Starr, PA
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[2] Philips Med Syst, Cleveland, OH USA
[3] Univ Calif San Francisco, Dept Neurosurg, San Francisco, CA 94143 USA
[4] Univ Calif San Francisco, Dept Neurol, San Francisco, CA 94143 USA
[5] Image Guided Neurol, Melbourne, FL USA
[6] Univ Calif San Francisco, Dept Anesthesia & Perioperat Med, San Francisco, CA 94143 USA
[7] Univ Calif San Francisco, Dept Nursing, San Francisco, CA 94143 USA
关键词
interventional MR; DBS electrodes; Parkinson's disease; MR fluoroscopy; implants;
D O I
10.1002/mrm.20675
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A methodology is presented for placing deep brain stimulator electrodes under direct MR image guidance. The technique utilized a small, skull-mounted trajectory guide that is optimized for accurate alignment under MR fluoroscopy. Iterative confirmation scans are used to monitor device alignment and brain penetration. The methodology was initially tested in a human skull phantom and proved capable of achieving submillimeter accuracy over a set of 16 separate targets that were accessed. The maximum error that was obtained in this preliminary test was 2 mm, motivating use of the technique in a clinical study. Subsequently, a total of eight deep brain stimulation electrodes were placed in five patients. Satisfactory placement was achieved on the first pass in seven of eight electrodes, while two passes were required with one electrode. Mean error from the intended target on the first pass was 1.0 +/- 0.8 mm (range = 0.1-1.9 mm). All procedures were considered technical successes and there were no intraoperative complications; however, one patient did develop a postoperative infection. Magn Reson Med 54:1107-1114,2005. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:1107 / 1114
页数:8
相关论文
共 25 条
[1]   Evaluation of specific absorption rate as a dosimeter of MRI-related implant heating [J].
Baker, KB ;
Tkach, JA ;
Nyenhuis, JA ;
Phillips, M ;
Shellock, FG ;
Gonzalez-Martinez, J ;
Rezai, AR .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (02) :315-320
[2]   Electrical and thermal behavior of non-ferrous noble metal electrodes exposed to MRI fields [J].
Bhavaraju, NC ;
Nagaraddi, V ;
Chetlapalli, SR ;
Osorio, I .
MAGNETIC RESONANCE IMAGING, 2002, 20 (04) :351-357
[3]   Risk factors for hemorrhage during microelectrode-guided deep brain stimulator implantation for movement disorders [J].
Binder, DK ;
Rau, GM ;
Starr, PA .
NEUROSURGERY, 2005, 56 (04) :722-728
[4]   Functional neurosurgery in the MRI environment [J].
De Salles, AAF ;
Frighetto, L ;
Behnke, E ;
Sinha, S ;
Tseng, L ;
Torres, R ;
Lee, M ;
Cabatan-Awang, C ;
Frysinger, R .
MINIMALLY INVASIVE NEUROSURGERY, 2004, 47 (05) :284-289
[5]   THE EFFECT OF MAGNETIC-RESONANCE IMAGERS ON IMPLANTED NEUROSTIMULATORS [J].
GLEASON, CA ;
KAULA, NF ;
HRICAK, H ;
SCHMIDT, RA ;
TANAGHO, EA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (01) :81-94
[6]   Brain biopsy sampling by using prospective stereotaxis and a trajectory guide [J].
Hall, WA ;
Liu, HY ;
Martin, AJ ;
Maxwell, RE ;
Truwit, CL .
JOURNAL OF NEUROSURGERY, 2001, 94 (01) :67-71
[7]   Neurophysiological identification of the subthalamic nucleus in surgery for Parkinson's disease [J].
Hutchison, WD ;
Allan, RJ ;
Opitz, H ;
Levy, R ;
Dostrovsky, JO ;
Lang, AE ;
Lozano, AM .
ANNALS OF NEUROLOGY, 1998, 44 (04) :622-628
[8]   Five-year follow-up of bilateral stimulation of the subthalamic nucleus in advanced Parkinson's disease [J].
Krack, P ;
Batir, A ;
Van Blercom, N ;
Chabardes, S ;
Fraix, V ;
Ardouin, C ;
Koudsie, A ;
Limousin, PD ;
Benazzouz, A ;
LeBas, JF ;
Benabid, AL ;
Pollak, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 349 (20) :1925-1934
[9]  
Liu HY, 2001, J MAGN RESON IMAGING, V13, P16, DOI 10.1002/1522-2586(200101)13:1<16::AID-JMRI1003>3.0.CO
[10]  
2-B