In Vivo Ultra-Fast Photoacoustic Flow Cytometry of Circulating Human Melanoma Cells Using Near-Infrared High-Pulse Rate Lasers

被引:61
作者
Nedosekin, Dmitry A. [1 ]
Sarimollaoglu, Mustafa [1 ]
Ye, Jian-Hui [1 ]
Galanzha, Ekaterina I. [1 ]
Zharov, Vladimir P. [1 ]
机构
[1] Univ Arkansas Med Sci, Philips Class Laser & Nanomed Labs, Little Rock, AR 72205 USA
基金
美国国家科学基金会;
关键词
in vivo flow cytometry; photoacoustics; melanoma; metastasis; circulating tumor cells; high-pulse repetition rate laser; magnetic nanoparticles; in vivo cell enrichment; POLYMERASE CHAIN-REACTION; TUMOR-CELLS; REVERSE-TRANSCRIPTASE; LYMPH-FLOW; BLOOD; TOMOGRAPHY;
D O I
10.1002/cyto.a.21102
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The circulating tumor cells (CTCs) appear to be a marker of metastasis development, especially, for highly aggressive and epidemically growing melanoma malignancy that is often metastatic at early stages. Recently, we introduced in vivo photoacoustic (PA) flow cytometry (PAFC) for label-free detection of mouse B16F10 CTCs in melanoma-bearing mice using melanin as an intrinsic marker. Here, we significantly improve the speed of PAFC by using a high-pulse repetition rate laser operating at 820 and 1064 nm wavelengths. This platform was used in preclinical studies for label-free PA detection of low-pigmented human CTCs. Demonstrated label-free PAFC detection, low level of background signals, and favorable safety standards for near-infrared irradiation suggest that a fiber laser operating at 1064 nm at pulse repetition rates up to 0.5 MHz could be a promising source for portable clinical PAFC devices. The possible applications can include early diagnosis of melanoma at the parallel progression of primary tumor and CTCs, detection of cancer recurrence, residual disease and real-time monitoring of therapy efficiency by counting CTCs before, during, and after therapeutic intervention. Herewith, we also address sensitivity of label-free detection of melanoma CTCs and introduce in vivo CTC targeting by magnetic nanoparticles conjugated with specific antibody and magnetic cells enrichment. (C) 2011 International Society for Advancement of Cytometry
引用
收藏
页码:825 / 833
页数:9
相关论文
共 33 条
[21]   Quantum Dots as Multimodal Photoacoustic and Photothermal Contrast Agents [J].
Shashkov, Evgeny V. ;
Everts, Maaike ;
Galanzha, Ekaterina I. ;
Zharov, Vladimir P. .
NANO LETTERS, 2008, 8 (11) :3953-3958
[22]   DETECTION OF MELANOMA-CELLS IN PERIPHERAL-BLOOD BY MEANS OF REVERSE-TRANSCRIPTASE AND POLYMERASE CHAIN-REACTION [J].
SMITH, B ;
SELBY, P ;
SOUTHGATE, J ;
PITTMAN, K ;
BRADLEY, C ;
BLAIR, GE .
LANCET, 1991, 338 (8777) :1227-1229
[23]   Isolation of circulating tumor cells using a microvortex-generating herringbone-chip [J].
Stott, Shannon L. ;
Hsu, Chia-Hsien ;
Tsukrov, Dina I. ;
Yu, Min ;
Miyamoto, David T. ;
Waltman, Belinda A. ;
Rothenberg, S. Michael ;
Shah, Ajay M. ;
Smas, Malgorzata E. ;
Korir, George K. ;
Floyd, Frederick P., Jr. ;
Gilman, Anna J. ;
Lord, Jenna B. ;
Winokur, Daniel ;
Springer, Simeon ;
Irimia, Daniel ;
Nagrath, Sunitha ;
Sequist, Lecia V. ;
Lee, Richard J. ;
Isselbacher, Kurt J. ;
Maheswaran, Shyamala ;
Haber, Daniel A. ;
Toner, Mehmet .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2010, 107 (43) :18392-18397
[24]  
Visús C, 2007, MELANOMA RES, V17, P83
[25]   Multiscale photoacoustic microscopy and computed tomography [J].
Wang, Lihong V. .
NATURE PHOTONICS, 2009, 3 (09) :503-509
[26]  
Wang LV, 2009, OPT SCI ENG-CRC, V144, P1, DOI 10.1201/9781420059922
[27]   Circulating tumor cells: approaches to isolation and characterization [J].
Yu, Min ;
Stott, Shannon ;
Toner, Mehmet ;
Maheswaran, Shyamala ;
Haber, Daniel A. .
JOURNAL OF CELL BIOLOGY, 2011, 192 (03) :373-382
[28]  
Zharov V., 2004, P SOC PHOTO-OPT INS, V5320, P256
[29]  
Zharov V. P., 1986, LASER OPTOACOUSTIC S
[30]   Photoacoustic flow cytometry:: principle and application for real-time detection of circulating single nanoparticles, pathogens, and contrast dyes in vivo [J].
Zharov, Vladimir P. ;
Galanzha, Ekaterina I. ;
Shashkov, Evgeny V. ;
Kim, Jin-Woo ;
Khlebtsov, Nikolai G. ;
Tuchin, Valery V. .
JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (05)