Commentary: The Pennsylvania Postmarket Multicenter Experience With Flow Redirection Endoluminal Device

被引:1
作者
Restrepo, Andres F. [1 ,2 ]
Singer, Justin [1 ,2 ]
机构
[1] Spectrum Hlth, Neurosurg Div, Dept Clin Neurosci, Grand Rapids, MI USA
[2] Michigan State Univ, Dept Neurosurg, Coll Human Med, Grand Rapids, MI USA
关键词
INTRACRANIAL ANEURYSMS; THROMBOGENICITY; DIVERTORS; PIPELINE; STENT;
D O I
10.1227/neu.0000000000002114
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
[No abstract available]
引用
收藏
页码:E109 / E110
页数:2
相关论文
共 14 条
[1]   Flow Diverters for Intracranial Aneurysms [J].
Alderazi, Yazan J. ;
Shastri, Darshan ;
Kass-Hout, Tareq ;
Prestigiacomo, Charles J. ;
Gandhi, Chirag D. .
STROKE RESEARCH AND TREATMENT, 2014, 2014
[2]   Pipeline for Uncoilable or Failed Aneurysms: Results from a Multicenter Clinical Trial [J].
Becske, Tibor ;
Kallmes, David F. ;
Saatci, Isil ;
McDougall, Cameron G. ;
Szikora, Istvn ;
Lanzino, Giuseppe ;
Moran, Christopher J. ;
Woo, Henry H. ;
Lopes, Demetrius K. ;
Berez, Aaron L. ;
Cher, Daniel J. ;
Siddiqui, Adnan H. ;
Levy, Elad I. ;
Albuquerque, Felipe C. ;
Fiorella, David J. ;
Berentei, Zsolt ;
Marosfoi, Miklos ;
Cekirge, Saruhan H. ;
Nelson, Peter K. .
RADIOLOGY, 2013, 267 (03) :858-868
[3]   Endovascular treatment of cerebral aneurysms using flow-diverter devices: A systematic review [J].
Briganti, Francesco ;
Leone, Giuseppe ;
Marseglia, Mariano ;
Mariniello, Giuseppe ;
Caranci, Ferdinando ;
Brunetti, Arturo ;
Maiuri, Francesco .
NEURORADIOLOGY JOURNAL, 2015, 28 (04) :365-375
[4]   In-vitro thrombogenicity assessment of flow diversion and aneurysm bridging devices [J].
Girdhar, Gaurav ;
Li, Junwei ;
Kostousov, Larisa ;
Wainwright, John ;
Chandler, Wayne L. .
JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2015, 40 (04) :437-443
[5]   Thrombogenicity of flow diverters in an ex vivo shunt model: effect of phosphorylcholine surface modification [J].
Hagen, Matthew W. ;
Girdhar, Gaurav ;
Wainwright, John ;
Hinds, Monica T. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2017, 9 (10) :1006-1011
[6]   European Multicenter Study for the Evaluation of a Dual-Layer Flow-Diverting Stent for Treatment of Wide-Neck Intracranial Aneurysms: The European Flow-Redirection Intraluminal Device Study [J].
Killer-Oberpfalzer, M. ;
Kocer, N. ;
Griessenauer, C. J. ;
Janssen, H. ;
Engelhorn, T. ;
Holtmannspotter, M. ;
Buhk, J. H. ;
Finkenzeller, T. ;
Fesl, G. ;
Trenkler, J. ;
Reith, W. ;
Berlis, A. ;
Hausegger, K. ;
Augustin, M. ;
Islak, C. ;
Minnich, B. ;
Moehlenbruch, M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (05) :841-847
[7]   Flow Re-direction Endoluminal Device in treatment of cerebral aneurysms: initial experience with short-term follow-up results [J].
Kocer, Naci ;
Islak, Civan ;
Kizilkilic, Osman ;
Kocak, Burak ;
Saglam, Muzaffer ;
Tureci, Ercan .
JOURNAL OF NEUROSURGERY, 2014, 120 (05) :1158-1171
[8]   Two- to five-year follow-up of 78 patients after treatment with the Flow Redirection Endoluminal Device [J].
Luecking, Hannes ;
Doerfler, Arnd ;
Goelitz, Philipp ;
Hoelter, Philip ;
Engelhorn, Tobias ;
Lang, Stefan .
INTERVENTIONAL NEURORADIOLOGY, 2020, 26 (01) :38-44
[9]   Safety and efficacy results of the Flow Redirection Endoluminal Device (FRED) stent system in the treatment of intracranial aneurysms: US pivotal trial [J].
McDougall, Cameron G. ;
Diaz, Orlando ;
Boulos, Alan ;
Siddiqui, Adnan H. ;
Caplan, Justin ;
Fifi, Johanna T. ;
Turk, Aquilla S. ;
Kayan, Yasha ;
Jabbour, Pascal ;
Kim, Louis J. ;
Hetts, Steven W. ;
Cooke, Daniel L. ;
Dowd, Christopher F. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2022, 14 (06) :577-584
[10]   The FRED Flow-Diverter Stent for Intracranial Aneurysms: Clinical Study to Assess Safety and Efficacy [J].
Moehlenbruch, M. A. ;
Herweh, C. ;
Jestaedt, L. ;
Stampfl, S. ;
Schoenenberger, S. ;
Ringleb, P. A. ;
Bendszus, M. ;
Pham, M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (06) :1155-1161