Staff knowledge of radiation protection - Multicentric study in Tunis university hospitals

被引:5
作者
Kamoun, H. [1 ]
Abbes, D. [2 ]
Kamoun, K. Anis [3 ]
Attia, N. [4 ]
Hammou, A. [5 ]
机构
[1] Hosp Univ Pathol Profess, Fac Med Tunis, Ctr Natl Radioprotect, Unite Radioprotect Travailleurs, Tunis, Tunisia
[2] Fac Med Tunis, Ctr Natl Radioprotect, Tunis, Tunisia
[3] Hosp Univ Chirurg Orthoped, Fac Med Tunis, Inst Kassab Chirurg Orthoped, Tunis, Tunisia
[4] Fac Med Tunis, Dept Med Prevent, Tunis, Tunisia
[5] Fac Med Tunis, CNRP, Tunis, Tunisia
关键词
Ionising radiation; Radiation protection; X-rays; Fluoroscopy; Interventional radiology; Orthopaedics; IONIZING-RADIATION; EXPOSURE; SURGEON; FIXATION; FLUOROSCOPY; PATIENT; FRANCE; ENOUGH;
D O I
10.1016/j.admp.2015.01.001
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Purpose. To evaluate the knowledge of orthopaedic operating staff on the radiation protection in Tunis university hospitals. Materials and methods. Our study was a cross-sectional descriptive study. A questionnaire was given to medical and paramedical professionals working in 6 orthopaedic operating rooms in Tunis. We have calculated the Global Knowledge Score for each respondent (GKS) and used non-parametric tests. Results. Within 259 workers, 194 have responded to the questionnaire, giving a response rate of 75%. In our study, 128 (66%) were men (sex ratio: 0.52), 120 (62%) were paramedical and 74 (38%) were medical doctors. The average GKS was 10/17, and significantly different according to professional grade (P = 0.0001). The average GKS was higher in "Trauma and burn Centre" than Rabta Hospital (P = 0.044). There was no significant difference between other hospitals. Furthermore, 91(47%) workers did not know that 2 meters distance considerably reduces personal display to X-rays and 42 (22%) did not know individual means of protection against ionizing radiation's weak doses. Conclusion. Establishing a radiation protection culture in orthopaedic operating room is imperative. Training is still one of the main elements in radiation protection. Person competent in radiation protection should be useful in the context of our study. (C) 2015 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:269 / 278
页数:10
相关论文
共 29 条
  • [1] Scattered radiation during fixation of hip fractures - Is distance alone enough protection?
    Alonso, JA
    Shaw, DL
    Maxwell, A
    McGill, GP
    Hart, GC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (06): : 815 - 818
  • [2] [Anonymous], 1996, INT AT EN AG SAF SER
  • [3] The management of radiation protection in France
    Aubert, B.
    [J]. JOURNAL DE RADIOLOGIE, 2010, 91 (11): : 1201 - 1206
  • [4] Comparison between percutaneous and traditional fixation of lumbar spine fracture: Intraoperative radiation exposure levels and outcomes
    Bronsard, N.
    Boli, T.
    Challali, M.
    de Dompsure, R.
    Amoretti, N.
    Padovani, B.
    Bruneton, G.
    Fuchs, A.
    de Peretti, F.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2013, 99 (02) : 162 - 168
  • [5] Radiation protection in the operating theatre
    Castagnet, X.
    Amabile, J. -C.
    Cazoulat, A.
    Bohand, S.
    Laroche, P.
    [J]. ARCHIVES DES MALADIES PROFESSIONNELLES ET DE L ENVIRONNEMENT, 2009, 70 (04) : 373 - 384
  • [6] Basis for an evaluation of needs of orthopaedic surgeons in France
    Caton, J.
    Duburcq, A.
    [J]. REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2006, 92 (08): : 818 - 826
  • [7] Evaluating the effectiveness of a radiation safety training intervention for oncology nurses: A pretest - intervention - posttest study
    Dauer L.T.
    Kelvin J.F.
    Horan C.L.
    St. Germain J.
    [J]. BMC Medical Education, 6 (1)
  • [8] Cervical spine imaging using standard C-arm fluoroscopy
    Giordano, Brian D.
    Baumhauer, Judith F.
    Morgan, Thomas L.
    Rechtine, Glenn R.
    [J]. SPINE, 2008, 33 (18) : 1970 - 1976
  • [9] Ionising radiation awareness among resident doctors, interns, and radiographers in a university hospital emergency department
    Gunalp, Muge
    Gulunay, Behnan
    Polat, Onur
    Demirkan, Arda
    Gurler, Serdar
    Akkas, Meltem
    Aksu, Nalan Metin
    [J]. RADIOLOGIA MEDICA, 2014, 119 (06): : 440 - 447
  • [10] Hammou A., 2009, TUN ORTHOP, V2, P125