Clinical application of GAFCHROMIC® EBT film for in vivo dose measurements of total body irradiation radiotherapy

被引:36
作者
Su, Fan-Chi [1 ,2 ]
Shi, Chengyu [1 ,2 ]
Papanikolaou, Niko [1 ,2 ]
机构
[1] Canc Therapy & Res Ctr S Texas, Dept Med Phys, San Antonio, TX 78229 USA
[2] Univ Texas Hlth Sci Ctr San Antonio, San Antonio, TX 78229 USA
关键词
total body irradiation; radiochromic film; GAFCHROMICC (R) EBT; radiation dosimetry; in vivo dosimetry;
D O I
10.1016/j.apradiso.2007.09.015
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The GAFCHROMIC (R) EBT film model is a fairly new film product designed for absorbed dose measurements of high-energy photon beams. In vivo dosimetry for total body irradiation (TBI) remains a challenging task due to the extended source-to-surface distance (SSD), low dose rates, and he use of beam spoilers. EBT film samples were used for dose measurements on an anthropomorphic phantom using a TBI setup. Additionally, in vivo measurements were obtained for two TBI patients. Phantom results verified the suitability of the EBT film for TBI treatment in terms of accuracy, reproducibility, and dose linearity. Doses measured were compared to conventional dosimeter measurements using thermoluminescent dosimeters (TLDs), resulting in an agreement of 4.1 % and 6.7% for the phantom and patient measurements, respectively. Results obtained from the phantom and patients confirm that GAFCHROMIC (R) EBT films are a suitable alternative to TLDs as an in vivo dosimeter in TBI radiotherapy. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:389 / 394
页数:6
相关论文
共 12 条
  • [1] *AAPM, 1986, 17 AAPM AM I PHYS
  • [2] Clinical application of the OneDose™ Patient Dosimetry System for total body irradiation
    Best, S
    Ralston, A
    Suchowerska, N
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (24) : 5909 - 5919
  • [3] Weak energy dependence of EBT gafchromic film dose response in the 50 kVp-10 MVp X-ray range
    Butson, MJ
    Cheung, T
    Yu, PKN
    [J]. APPLIED RADIATION AND ISOTOPES, 2006, 64 (01) : 60 - 62
  • [4] Independence of calibration curves for EBT Gafchromic films of the size of high-energy X-ray fields
    Cheung, Tsang
    Butson, Martin J.
    Yu, Peter K. N.
    [J]. APPLIED RADIATION AND ISOTOPES, 2006, 64 (09) : 1027 - 1030
  • [5] Dosimetric properties of improved GafChromic films for seven different digitizers
    Devic, S
    Seuntjens, J
    Hegyi, G
    Podgorsak, EB
    Soares, CG
    Kirov, AS
    Ali, I
    Williamson, JF
    Elizondo, A
    [J]. MEDICAL PHYSICS, 2004, 31 (09) : 2392 - 2401
  • [6] Precise radiochromic film dosimetry using a flat-bed document scanner
    Devic, S
    Seuntjens, J
    Sham, E
    Podgorsak, EB
    Schmidtlein, CR
    Kirov, AS
    Soares, CG
    [J]. MEDICAL PHYSICS, 2005, 32 (07) : 2245 - 2253
  • [7] Dusenberry KE, 1999, TECHNOLOGICAL BASIS, P499
  • [8] Composite depth dose measurement for total skin electron (TSE) treatments using radiochromic film
    Gamble, LM
    Farrell, TJ
    Jones, GW
    Hayward, JE
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (07) : 891 - 898
  • [9] *ISP COP, 2006, GAFCHROMIC EBT SELF
  • [10] KAHN FM, 2003, PHYS RAD THERAPY, P455