Transcranial Doppler to Detect Right to Left Communication: Evaluation Versus Transesophageal Echocardiography in Real Life

被引:12
作者
Maillet, Alexandre [1 ]
Pavero, Antoine [1 ]
Salaun, Pierre [1 ]
Pibourdin, Alexis [1 ]
Skopinski, Sophie [1 ]
Thambo, Jean-Benoit [2 ]
Sibon, Igor [3 ]
Constans, Joel [1 ]
Boulon, Carine [1 ]
机构
[1] Hop St Andre, Serv Med Vasc, 1 Rue Jean Burguet, F-33075 Bordeaux, France
[2] Hop Cardiol, Serv Malad Cardiovasc Congenitales, Pessac, France
[3] Hop Pellegrin, Unite Neurovasc, Bordeaux, France
关键词
cardiovascular disease; peripheral arterial disease; stroke; thrombosis; PATENT FORAMEN OVALE; CRYPTOGENIC STROKE; TRANSTHORACIC ECHOCARDIOGRAPHY; LEFT SHUNTS; CONTRAST; ULTRASONOGRAPHY; METAANALYSIS; PREVALENCE; ULTRASOUND; SONOGRAPHY;
D O I
10.1177/0003319717712356
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
We compared transcranial Doppler (TCD) with transesophageal echocardiography (TEE) and transthoracic echocardiography (TTE) for the detection of right to left communication (RLC) in the heart. All patients explored from 2013 to 2016 in a vascular medicine unit to detect RLC by TCD were included. Right to left communication was detected by TCD monitoring for microembolic signals after intravenous injection of agitated 5% glucose and air. One hundred one patients were explored for RLC by TCD, 64 by TEE (not possible in 10, bubble injection in 51), and 93 by TTE because of unexplained stroke or arterial thrombosis (51 males, 50 females, age 51.0 +/- 15.8 years) (bubble injection in 35). Fifty-three patients were positive after TCD (TEE: 4 negative, TTE: 7 negative). Of the negative patients after TCD, none was positive for TEE and 1 was positive for TTE with no evidence of patent foramen ovale. Transcranial Doppler was sensitive to detect RLC, even in patients with negative TTE or TTE. A negative TEE did not exclude RLC demonstrated by TCD. Transcranial Doppler might be proposed as first line to detect RLC.
引用
收藏
页码:79 / 82
页数:4
相关论文
共 25 条
[1]   Transcranial duplex sonography in the detection of patent foramen ovalle [J].
Blersch, WK ;
Draganski, BM ;
Holmer, SR ;
Koch, HJ ;
Schlachetzki, F ;
Bogdahn, U ;
Hölscher, T .
RADIOLOGY, 2002, 225 (03) :693-699
[2]   ATRIAL SEPTAL ANEURYSM AND PATENT FORAMEN OVALE AS RISK-FACTORS FOR CRYPTOGENIC STROKE IN PATIENTS LESS-THAN 55 YEARS OF AGE - A STUDY USING TRANSESOPHAGEAL ECHOCARDIOGRAPHY [J].
CABANES, L ;
MAS, JL ;
COHEN, A ;
AMARENCO, P ;
CABANES, PA ;
OUBARY, P ;
CHEDRU, F ;
GUERIN, F ;
BOUSSER, MG ;
DERECONDO, J .
STROKE, 1993, 24 (12) :1865-1873
[3]   Morphological and functional characteristics of patent foramen ovale and their embolic implications [J].
De Castro, S ;
Cartoni, D ;
Fiorelli, M ;
Rasura, M ;
Anzini, A ;
Zanette, EM ;
Beccia, M ;
Colonnese, C ;
Fedele, F ;
Fieschi, C ;
Pandian, NG .
STROKE, 2000, 31 (10) :2407-2413
[4]   COMPARISON OF DIAGNOSTIC-TECHNIQUES FOR THE DETECTION OF A PATENT FORAMEN OVALE IN STROKE PATIENTS [J].
DITULLIO, M ;
SACCO, RL ;
VENKETASUBRAMANIAN, N ;
SHERMAN, D ;
MOHR, JP ;
HOMMA, S .
STROKE, 1993, 24 (07) :1020-1024
[5]   Optimizing the technique of contrast transcranial Doppler ultrasound in the detection of right-to-left shunts [J].
Droste, DW ;
Lakemeier, S ;
Wichter, T ;
Stypmann, J ;
Dittrich, R ;
Ritter, M ;
Moeller, M ;
Freund, M ;
Ringelstein, B .
STROKE, 2002, 33 (09) :2211-2216
[6]   Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts -: Reproducibility, comparison of 2 agents, and distribution of microemboli [J].
Droste, DW ;
Reisener, M ;
Kemény, V ;
Dittrich, R ;
Schulte-Altedorneburg, G ;
Stypmann, J ;
Wichter, T ;
Ringelstein, EB .
STROKE, 1999, 30 (05) :1014-1018
[7]   INCIDENCE AND SIZE OF PATENT FORAMEN OVALE DURING THE 1ST 10 DECADES OF LIFE - AN AUTOPSY STUDY OF 965 NORMAL HEARTS [J].
HAGEN, PT ;
SCHOLZ, DG ;
EDWARDS, WD .
MAYO CLINIC PROCEEDINGS, 1984, 59 (01) :17-20
[8]   CHARACTERISTICS OF PATENT FORAMEN OVALE ASSOCIATED WITH CRYPTOGENIC STROKE - A BIPLANE TRANSESOPHAGEAL ECHOCARDIOGRAPHIC STUDY [J].
HOMMA, S ;
DITULLIO, MR ;
SACCO, RL ;
MIHALATOS, D ;
MANDRI, GL ;
MOHR, JP .
STROKE, 1994, 25 (03) :582-586
[9]   COMPARISON OF TRANSCRANIAL CONTRAST DOPPLER SONOGRAPHY AND TRANSESOPHAGEAL CONTRAST ECHOCARDIOGRAPHY FOR THE DETECTION OF PATENT FORAMEN OVALE IN YOUNG STROKE PATIENTS [J].
JOB, FP ;
RINGELSTEIN, EB ;
GRAFEN, Y ;
FLACHSKAMPF, FA ;
DOHERTY, C ;
STOCKMANNS, A ;
HANRATH, P .
AMERICAN JOURNAL OF CARDIOLOGY, 1994, 74 (04) :381-384
[10]   Transcranial Doppler versus transthoracic echocardiography for the detection of patent foramen ovale in patients with cryptogenic cerebral ischemia: A systematic review and diagnostic test accuracy meta-analysis [J].
Katsanos, Aristeidis H. ;
Psaltopoulou, Theodora ;
Sergentanis, Theodoros N. ;
Frogoudaki, Alexandra ;
Vrettou, Agathi-Rosa ;
Ikonomidis, Ignatios ;
Paraskevaidis, Ioannis ;
Parissis, John ;
Bogiatzi, Chrysa ;
Zompola, Christina ;
Ellul, John ;
Triantafyllou, Nikolaos ;
Voumvourakis, Konstantinos ;
Kyritsis, Athanassios P. ;
Giannopoulos, Sotirios ;
Alexandrov, Anne W. ;
Alexandrov, Andrei V. ;
Tsivgoulis, Georgios .
ANNALS OF NEUROLOGY, 2016, 79 (04) :625-635