A prospective, split face, single-blinded study looking at the use of an infrared device with contact cooling in the treatment of skin laxity in Asians

被引:21
作者
Chan, Henry H. [1 ,2 ,3 ]
Yu, C. S. [1 ]
Shek, S. [1 ]
Yeung, C. K. [1 ]
Kono, T. [4 ]
Wei, W. I. [5 ]
机构
[1] Univ Hong Kong, Dept Med, Div Dermatol, Hong Kong, Hong Kong, Peoples R China
[2] Chinese Univ Hong Kong, Dept Med & Therapeut, Div Dermatol, Hong Kong, Hong Kong, Peoples R China
[3] Chinese Univ Hong Kong, Dept Pediat, Hong Kong, Hong Kong, Peoples R China
[4] Tokyo Womens Med Sch, Dept Plast & Reconstruct Surg, Tokyo, Japan
[5] Univ Hong Kong, Dept Surg, Hong Kong, Hong Kong, Peoples R China
关键词
infrared; Asians; skin tightening; RADIOFREQUENCY;
D O I
10.1002/lsm.20586
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background: Although monopolar radiofrequency treatment is effective in the improvement of skin laxity, the pain and cost that are associated with this method suggest the need for alternative treatment options. Recently, an infrared device with contact cooling has been shown to be effective in the treatment of skin laxity, with ultrastructural changes observed that are similar to those that are observed following treatment with a monopolar radiofrequency device. However, no control was included in previous studies. Objective: To conduct a prospective, split-face, single-blinded study to look at the efficacy and complications among Asians of treatment for skin tightening with an infrared device with contact cooling. Method: Thirteen Chinese women were treated. An infrared device with contact cooling (Titan, Cutera, Brisbane, CA) was used to treat one side of the face and the untreated side served as the control. The treatment was performed twice with a 4-week interval between the treatments and the patients were followed up by subjective assessment using a structured questionnaire I and 3 months after the second (and last) treatment. In all cases, pre- and post-treatment clinical photographs were taken. Two independent observers assessed the photographs. Results: Twenty-three percentage of patients reported mild improvement, 15% reported moderate improvement, and 54% reported significant improvement 3 months after their second (and last) treatment. In terms of objective assessment, 41% of patients were identified to have some degree of improvement of the treated side 3 months after their second treatment. Compared with the untreated side, the treated side improved significantly (P = 0.031) at 1 and 3 months after the second treatment. Blistering occurred in one patient, which had resolved completely by the 3-month follow-up visit. Conclusion: An infrared device with contact cooling can be used effectively and safely for the treatment of skin laxity, especially in smaller anatomical areas.
引用
收藏
页码:146 / 152
页数:7
相关论文
共 11 条
[1]   Evaluation of the multiple pass, low fluence algorithm for radiofrequency tightening of the lower face [J].
Bogle, Melissa A. ;
Ubelhoer, Nathan ;
Weiss, Robert A. ;
Mayoral, Flor ;
Kaminer, Michael S. .
LASERS IN SURGERY AND MEDICINE, 2007, 39 (03) :210-217
[2]   Nonablative infrared skin tightening in type IV to v Asian skin: A prospective clinical study [J].
Chua, Sze-Hon ;
Ang, Por ;
Khoo, Lawrence S. W. ;
Goh, Chee-Leok .
DERMATOLOGIC SURGERY, 2007, 33 (02) :146-151
[3]   The role of deep heating for noninvasive skin rejuvenation [J].
Dierickx, Christine C. .
LASERS IN SURGERY AND MEDICINE, 2006, 38 (09) :799-807
[4]   Multicenter study of noninvasive radiofrequency for periorbital tissue tightening [J].
Fitzpatrick, R ;
Geronemus, R ;
Goldberg, D ;
Kaminer, M ;
Kilmer, S ;
Ruiz-Esparza, J .
LASERS IN SURGERY AND MEDICINE, 2003, 33 (04) :232-242
[5]  
Matory W., 1998, ETHNIC CONSIDERATION, P100
[6]   Why does carbon dioxide resurfacing work? A Review [J].
Ross, EV ;
McKinlay, JR ;
Anderson, RR .
ARCHIVES OF DERMATOLOGY, 1999, 135 (04) :444-454
[7]   Painless, nonablative, immediate skin contraction induced by low-fluence irradiation with new infrared device: A report of 25 patients [J].
Ruiz-Esparza, Javier .
DERMATOLOGIC SURGERY, 2006, 32 (05) :601-610
[8]  
WHITE WM, 2006, LASERS SURG MED S, V18, P113
[9]  
YU C, 2007, LASERS SURG MED S, V19, P65
[10]   Histological and ultrastructural evaluation of the effects of a radiofrequency-based nonablative dermal remodeling device - A pilot study [J].
Zelickson, BD ;
Kist, D ;
Bernstein, E ;
Brown, DB ;
Ksenzenko, S ;
Burns, J ;
Kilmer, S ;
Mehregan, D ;
Pope, K .
ARCHIVES OF DERMATOLOGY, 2004, 140 (02) :204-209