Magnetic resonance angiography in the management of aneurysmal subarachnoid haemorrhage: A study of 51 cases

被引:23
作者
Sankhla, SK
Gunawardena, WJ
Coutinho, CMA
Jones, AP
Keogh, AJ
机构
[1] ROYAL PRESTON HOSP,DEPT NEUROL SURG,PRESTON PR2 4HT,LANCS,ENGLAND
[2] ROYAL PRESTON HOSP,DEPT NEURORADIOL,PRESTON PR2 4HT,LANCS,ENGLAND
[3] ROYAL PRESTON HOSP,NW PHYS DEPT,PRESTON PR2 4HT,LANCS,ENGLAND
关键词
subarachnoid haemorrhage; intracranial aneurysm; magnetic resonance angiography;
D O I
10.1007/s002340050336
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We report preliminary experience with the use of magnetic resonance angiography (MRA) in the assessment of intracranial aneurysms. The aims of the study were to confirm that aneurysms could be detected and to assess the quality of the images with a view to early surgery if clinically indicated. We studied 51 patients with recent spontaneous subarachnoid haemorrhage with MRA, using a three-dimensional time-of-flight technique. The results of MRA were subsequently confirmed on intra-arterial digital subtraction angiography (IA-DSA) for anatomical correlation, and were considered satisfactory in 38 patients (74.5 %). In 20 patients early surgical obliteration of their aneurysm was possible on the MRA results without recourse to IA-DSA. A total of 37 aneurysms were identified in 32 patients, while the remaining 6 patients did not have an aneurysm. MRA was misinterpreted in 4 patients (7.9 %), and in 9 other patients (17.6 %) MRA was un satisfactory due to movement artefacts.
引用
收藏
页码:724 / 729
页数:6
相关论文
共 16 条
  • [1] DELINEATION OF UNRUPTURED CEREBRAL ANEURYSMS BY COMPUTERIZED ANGIOTOMOGRAPHY
    ASARI, S
    SATOH, T
    SAKURAI, M
    YAMAMOTO, Y
    SADAMOTO, K
    [J]. JOURNAL OF NEUROSURGERY, 1982, 57 (04) : 527 - 534
  • [2] ANGIOGRAPHIC FREQUENCY OF ANTERIOR CIRCULATION INTRACRANIAL ANEURYSMS
    ATKINSON, JLD
    SUNDT, TM
    HOUSER, OW
    WHISNANT, JP
    [J]. JOURNAL OF NEUROSURGERY, 1989, 70 (04) : 551 - 555
  • [3] IMPROVED TIME-OF-FLIGHT MR ANGIOGRAPHY OF THE BRAIN WITH MAGNETIZATION TRANSFER CONTRAST
    EDELMAN, RR
    AHN, SS
    CHIEN, D
    WEI, L
    GOLDMANN, A
    MANTELLO, M
    KRAMER, J
    KLEEFIELD, J
    [J]. RADIOLOGY, 1992, 184 (02) : 395 - 399
  • [4] SPATIAL PRESATURATION - A METHOD FOR SUPPRESSING FLOW ARTIFACTS AND IMPROVING DEPICTION OF VASCULAR ANATOMY IN MR IMAGING
    FELMLEE, JP
    EHMAN, RL
    [J]. RADIOLOGY, 1987, 164 (02) : 559 - 564
  • [5] MAGNETIC-RESONANCE ANGIOGRAPHY COMPARED TO INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY IN PATIENTS WITH SUBARACHNOID HEMORRHAGE
    GOULIAMOS, A
    GOTSIS, E
    VLAHOS, L
    SAMARA, C
    KAPSALAKI, E
    ROLOGIS, D
    KAPSALAKIS, Z
    PAPAVASILIOU, C
    [J]. NEURORADIOLOGY, 1992, 35 (01) : 46 - 49
  • [6] DETECTION OF INTRACRANIAL ANEURYSMS BY 3-DIMENSIONAL TIME-OF-FLIGHT MAGNETIC-RESONANCE ANGIOGRAPHY
    HORIKOSHI, T
    FUKAMACHI, A
    NISHI, H
    FUKASAWA, I
    [J]. NEURORADIOLOGY, 1994, 36 (03) : 203 - 207
  • [7] INPLANE VASCULAR IMAGING - PULSE SEQUENCE DESIGN AND STRATEGY
    LENZ, GW
    HAACKE, EM
    MASARYK, TJ
    LAUB, G
    [J]. RADIOLOGY, 1988, 166 (03) : 875 - 882
  • [8] LEWIN JS, 1991, AM J NEURORADIOL, V12, P1133
  • [9] INTRACRANIAL CIRCULATION - PRELIMINARY CLINICAL-RESULTS WITH 3-DIMENSIONAL (VOLUME) MR ANGIOGRAPHY
    MASARYK, TJ
    MODIC, MT
    ROSS, JS
    RUGGIERI, PM
    LAUB, GA
    LENZ, GW
    HAACKE, EM
    SELMAN, WR
    WIZNITZER, M
    HARIK, SI
    [J]. RADIOLOGY, 1989, 171 (03) : 793 - 799
  • [10] MASARYK TJ, 1991, MAGNETIC RESONANCE I, P1079