Comparison of two experimental ARDS models in pigs using electrical impedance tomography

被引:12
作者
Hochhausen, Nadine [1 ]
Orschulik, Jakob [2 ]
Follmann, Andreas [1 ]
Santos, Susana Aguiar [2 ]
Dohmeier, Henriette [1 ]
Leonhardt, Steffen [2 ]
Rossaint, Rolf [1 ]
Czaplik, Michael [1 ]
机构
[1] Rhein Westfal TH Aachen, Med Fac, Dept Anesthesiol, Aachen, Germany
[2] Rhein Westfal TH Aachen, Philips Chair Med Informat Technol, Aachen, Germany
来源
PLOS ONE | 2019年 / 14卷 / 11期
关键词
ACUTE RESPIRATORY-DISTRESS; ANIMAL-MODELS; LUNG; MECHANISMS; OUTCOMES;
D O I
10.1371/journal.pone.0225218
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Animal trials contribute to major achievements in medical science. The so-called lavage model is frequently used to evaluate ventilation strategies in acute respiratory distress syndrome (ARDS) using electrical impedance tomography (EIT). But, the lavage model itself might have systematic impacts on EIT parameters. Therefore, we established an additional experimental model, in which ARDS is caused by intravenously administered lipopolysaccharide (LPS). In this study, we want to examine if EIT measurements provide consistent results in both experimental models or whether the pathophysiology of the model influences the findings. Overall, we want to compare both experimental models regarding clinical parameters and EIT-derived indices, namely the global inhomogeneity (GI) index and the regional ventilation delay (RVD) index. Methods Nineteen pigs were included in this study, allocated to the control group (CO; n = 5), lavage group (LAV; n = 7) and LPS group (LPS; n = 7). After baseline measurements and the establishment of ARDS, assessment of respiratory mechanics, hemodynamics, gas exchange and EIT recordings were performed hourly over eight hours. Results In both experimental ARDS models, EIT measurements provided reliable results. But, the GI and the RVD index did not show consistent results as compared to the CO group. Initially, GI and RVD index were higher in the LAV group but not in the LPS group as compared to the CO group. This effect disappeared during the study. Furthermore, the GI index and the RVD index were higher in the LAV group compared to the LPS group in the beginning as well. This, once again, disappeared. Clinical lung injury parameters remained more stable when using LPS. Conclusion The two models showed quite different influences on the GI and RVD index. This implies, that the underlying pathophysiology affects EIT parameters and thus the findings. Hence, translation to EIT-guided clinical therapy in humans suffering from ARDS might be limited.
引用
收藏
页数:14
相关论文
共 29 条
  • [1] [Anonymous], 2011, GUIDE CARE USE LAB A
  • [2] ASHBAUGH DG, 1967, LANCET, V2, P319
  • [3] Large-Animal Models of Acute Respiratory Distress Syndrome
    Ballard-Croft, Cherry
    Wang, Dongfang
    Sumpter, L. Ryan
    Zhou, Xiaoqin
    Zwischenberger, Joseph B.
    [J]. ANNALS OF THORACIC SURGERY, 2012, 93 (04) : 1331 - 1339
  • [4] Mechanisms of bacterial lipopolysaccharide-induced endothelial apoptosis
    Bannerman, DD
    Goldblum, SE
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-LUNG CELLULAR AND MOLECULAR PHYSIOLOGY, 2003, 284 (06) : L899 - L914
  • [5] Becher T, 2017, PHYSL MEAS
  • [6] THE AMERICAN-EUROPEAN CONSENSUS CONFERENCE ON ARDS - DEFINITIONS, MECHANISMS, RELEVANT OUTCOMES, AND CLINICAL-TRIAL COORDINATION
    BERNARD, GR
    ARTIGAS, A
    BRIGHAM, KL
    CARLET, J
    FALKE, K
    HUDSON, L
    LAMY, M
    LEGALL, JR
    MORRIS, A
    SPRAGG, R
    COCHIN, B
    LANKEN, PN
    LEEPER, KV
    MARINI, J
    MURRAY, JF
    OPPENHEIMER, L
    PESENTI, A
    REID, L
    RINALDO, J
    VILLAR, J
    VANASBECK, BS
    DHAINAUT, JF
    MANCEBO, J
    MATTHAY, M
    MEYRICK, B
    PAYEN, D
    PERRET, C
    FOWLER, AA
    SCHALLER, MD
    HUDSON, LD
    HYERS, T
    KNAUS, W
    MATTHAY, R
    PINSKY, M
    BONE, RC
    BOSKEN, C
    JOHANSON, WG
    LEWANDOWSKI, K
    REPINE, J
    RODRIGUEZROISIN, R
    ROUSSOS, C
    ANTONELLI, MA
    BELOUCIF, S
    BIHARI, D
    BURCHARDI, H
    LEMAIRE, F
    MONTRAVERS, P
    PETTY, TL
    ROBOTHAM, J
    ZAPOL, W
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 149 (03) : 818 - 824
  • [7] Detection of 'best' positive end-expiratory pressure derived from electrical impedance tomography parameters during a decremental positive end-expiratory pressure trial
    Blankman, Paul
    Hasan, Djo
    Erik, Groot Jebbink
    Gommers, Diederik
    [J]. CRITICAL CARE, 2014, 18 (03):
  • [8] Bedside estimation of recruitable alveolar collapse and hyperdistension by electrical impedance tomography
    Costa, Eduardo L. V.
    Borges, Joao Batista
    Melo, Alexandre
    Suarez-Sipmann, Fernando
    Toufen, Carlos, Jr.
    Bohm, Stephan H.
    Amato, Marcelo B. P.
    [J]. INTENSIVE CARE MEDICINE, 2009, 35 (06) : 1132 - 1137
  • [9] Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: consensus statement of the TRanslational EIT developmeNt stuDy group
    Frerichs, Inez
    Amato, Marcelo B. P.
    van Kaam, Anton H.
    Tingay, David G.
    Zhao, Zhanqi
    Grychtol, Bartlomiej
    Bodenstein, Marc
    Gagnon, Herve
    Bohm, Stephan H.
    Teschner, Eckhard
    Stenqvist, Ola
    Mauri, Tommaso
    Torsani, Vinicius
    Camporota, Luigi
    Schibler, Andreas
    Wolf, Gerhard K.
    Gommers, Diederik
    Leonhardt, Steffen
    Adler, Andy
    [J]. THORAX, 2017, 72 (01) : 83 - 93
  • [10] Interaction of dependent and non-dependent regions of the acutely injured lung during a stepwise recruitment manoeuvre
    Gomez-Laberge, Camille
    Rettig, Jordan S.
    Smallwood, Craig D.
    Boyd, Theonia K.
    Arnold, John H.
    Wolf, Gerhard K.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2013, 34 (02) : 163 - 177