Monitoring Uranium, Hydrogen, and Lithium and Their Isotopes Using a Compact Laser-Induced Breakdown Spectroscopy (LIBS) Probe and High-Resolution Spectrometer

被引:117
作者
Cremers, David A. [1 ]
Beddingfield, Alan
Smithwick, Robert
Chinni, Rosemarie C. [2 ]
Jones, C. Randy [1 ]
Beardsley, Burt [3 ]
Karch, Larry [4 ]
机构
[1] Appl Res Associates Inc, Albuquerque, NM USA
[2] Alvernia Univ, Reading, PA USA
[3] Catalina Sci Instruments LLC, Tucson, AZ USA
[4] DTRA NTD, Ft Belvoir, VA USA
关键词
Laser-induced breakdown spectroscopy; LIBS; Uranium isotopes; Deuterium; Lithium isotopes; High-resolution spectrometer; Echelle spectrometer; EMISSION-SPECTROSCOPY; PLASMA;
D O I
10.1366/11-06314
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The development of field-deployable instruments to monitor radiological, nuclear, and explosive (RNE) threats is of current interest for a number of assessment needs such as the on-site screening of suspect facilities and nuclear forensics. The presence of uranium and plutonium and radiological materials can be determined through monitoring the elemental emission spectrum using relatively low-resolution spectrometers. In addition, uranium compounds, explosives, and chemicals used in nuclear fuel processing (e.g., tributyl-phosphate) can be identified by applying chemometric analysis to the laser-induced breakdown (LIBS) spectrum recorded by these spectrometers. For nuclear forensic applications, however, isotopes of U and Pu and other elements (e.g., H and Li) must also be determined, requiring higher resolution spectrometers given the small magnitude of the isotope shifts for some of these elements (e.g., 25 pm for U and 13 pm for Pu). High-resolution spectrometers will be preferred for several reasons hut these must fit into realistic field-based analysis scenarios. To address the need for field instrumentation, we evaluated a previously developed field-deployable hand-held LIBS interrogation probe combined with two relatively new high-resolution spectrometers (lambda/Delta lambda similar to 75 000 and similar to 44000) that have the potential to meet field-based analysis needs. These spectrometers are significantly smaller and lighter in weight than those previously used for isotopic analysis and one unit can provide simultaneous wide spectral coverage and high resolution in a relatively small package. The LIBS interrogation probe was developed initially for use with low resolution compact spectrometers in a person-portable backpack LIBS instrument. Here we present the results of an evaluation of the LIBS probe combined with a high-resolution spectrometer and demonstrate rapid detection of isotopes of uranium and hydrogen and highly enriched samples of Li-6 and Li-7.
引用
收藏
页码:250 / 261
页数:12
相关论文
共 9 条
[1]   Detection of Uranium Using Laser-Induced Breakdown Spectroscopy [J].
Chinni, Rosemarie C. ;
Cremers, David A. ;
Radziemski, Leon J. ;
Bostian, Melissa ;
Navarro-Northrup, Claudia .
APPLIED SPECTROSCOPY, 2009, 63 (11) :1238-1250
[2]  
Cremers D. A., 2010, P 51 INMM BALT MD JU
[3]   Determination of isotope ratios using Laser-Induced Breakdown Spectroscopy in ambient air at atmospheric pressure for nuclear forensics [J].
Doucet, Francois R. ;
Lithgow, Gregg ;
Kosierb, Rick ;
Bouchard, Paul ;
Sabsabi, Mohamad .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (03) :536-541
[4]   Determination of impurities in uranium and plutonium dioxides by laser-induced breakdown spectroscopy [J].
Fichet, P ;
Mauchien, P ;
Moulin, C .
APPLIED SPECTROSCOPY, 1999, 53 (09) :1111-1117
[5]  
Nuclear Weapons Technology, MIL CRIT TECHN LIS 2
[6]   Isotope ratio determination of uranium by optical emission spectroscopy on a laser-produced plasma - basic investigations and analytical results [J].
Pietsch, W ;
Petit, A ;
Briand, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (05) :751-761
[7]   A laser ablation-atomic fluorescence technique for isotopically selective determination of lithium in solids [J].
Smith, BW ;
Gornushkin, IB ;
King, LA ;
Winefordner, JD .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (6-8) :1131-1138
[8]   Pu-239/Pu-240 isotope ratios determined using high resolution emission spectroscopy in a laser-induced plasma [J].
Smith, CA ;
Martinez, MA ;
Veirs, DK ;
Cremers, DA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (05) :929-937
[9]   ISOTOPE EFFECTS IN THE DETERMINATION OF LITHIUM BY FLAMELESS ATOMIC-ABSORPTION SPECTROSCOPY [J].
VILCSEK, E ;
LOHMANN, G .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1979, 296 (2-3) :159-160