We studied the run-to-run repeatability of the retention times of both non-ionizable and basic compounds chromatographed using buffered eluents. The effect of flow rate, organic modifier and other additives, buffer type/concentration, stationary phase type, batch-to-batch preparation of the initial eluent, gradient time, sample type and intra-day changes on retention repeatability were examined. We also assessed the effect of column storage solvent conditions on the inter-day repeatability. Although retention repeatability is strongly influenced by many parameters (flow rate, solvent compressibility compensation, precision of temperature control, and buffer/stationary phase type), our primary finding is that with a reasonable size column (15 cm x 4.6 mm (i.d.)) two column volumes of re-equilibration with initial eluent suffices to provide acceptable repeatability (no worse than 0.004 min) for both non-ionizable and basic analytes under a wide variety of conditions. Under ideal conditions (e.g. the right buffer, flow rate, etc.) it is possible to obtain truly extraordinary repeatability often as good as 0.0004 min. These absolute fluctuations in retention translate to worst case changes in resolution of 0.2 units and average changes of only 0.02 units. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:41 / 53
页数:13
相关论文
共 66 条
[1]  
[Anonymous], 1960, PHYSICO CHEM CONSTAN
[2]  
[Anonymous], EASTMAN ORG CHEM B
[3]   High-throughput chromatographic approaches to liquid chromatographic/tandem mass spectrometric bioanalysis to support drug discovery and development [J].
Berna, MJ ;
Ackermann, BL ;
Murphy, AT .
ANALYTICA CHIMICA ACTA, 2004, 509 (01) :1-9
[4]  
BOGUSZ M, 1991, LC GC-MAG SEP SCI, V9, P290
[5]   AN OVERVIEW ON THE STANDARDIZATION OF CHROMATOGRAPHIC METHODS FOR SCREENING ANALYSIS IN TOXICOLOGY BY MEANS OF RETENTION INDEXES AND SECONDARY STANDARDS .2. HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BOGUSZ, M ;
FRANKE, JP ;
DEZEEUW, RA ;
ERKENS, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 347 (3-4) :73-81
[6]   Hyphenated liquid chromatographic techniques in forensic toxicology [J].
Bogusz, MJ .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 733 (1-2) :65-91
[7]   Chromatographic alignment by warping and dynamic programming as a pre-processing tool for PARAFAC modelling of liquid chromatography-mass spectrometry data [J].
Bylund, D ;
Danielsson, R ;
Malmquist, G ;
Markides, KE .
JOURNAL OF CHROMATOGRAPHY A, 2002, 961 (02) :237-244
[8]   HIGH-SPEED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PEPTIDES AND PROTEINS [J].
CHEN, H ;
HORVATH, C .
JOURNAL OF CHROMATOGRAPHY A, 1995, 705 (01) :3-20
[9]   THE SURFACE-TENSION OF MIXTURES OF METHANOL, ACETONITRILE, TETRAHYDROFURAN, ISOPROPANOL, TERTIARY BUTANOL AND DIMETHYLSULFOXIDE WITH WATER AT 25-DEGREES-C [J].
CHEONG, WJ ;
CARR, PW .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1987, 10 (04) :561-581
[10]  
Christensen J.J., 1976, HDB PROTON IONIZATIO