Tracking the picoscale spatial motion of atomic columns during dynamic structural change

被引:16
作者
Levin, Barnaby D. A. [1 ]
Lawrence, Ethan L. [1 ]
Crozier, Peter A. [1 ]
机构
[1] Arizona State Univ, Sch Engn Matter Transport & Energy, Tempe, AZ 85287 USA
基金
美国国家科学基金会;
关键词
atomic column; spatial motion; CeO2; In situ imaging; TRANSMISSION ELECTRON-MICROSCOPY; RESOLUTION; IMAGES; DETECTORS; SHAPE;
D O I
10.1016/j.ultramic.2020.112978
中图分类号
TH742 [显微镜];
学科分类号
摘要
In many materials systems, such as catalytic nanoparticles, the ability to characterize dynamic atomic structural changes is important for developing a more fundamental understanding of functionality. Recent developments in direct electron detection now allow image series to be acquired at frame rates on the order of 1000 frames per second in bright-field transmission electron microscopy (BF TEM), which could potentially allow dynamic changes in the atomic structure of individual nanoparticles to be characterized with millisecond temporal resolution in favorable cases. However, extracting such data from TEM image series requires the development of computational methods that can be applied to very large datasets and are robust in the presence of noise and in the non-ideal imaging conditions of some types of environmental TEM experiments. Here, we present a two-dimensional Gaussian fitting algorithm to track the position and intensities of atomic columns in temporally resolved BF TEM image series. We have tested our algorithm on experimental image series of Ce atomic columns near the surface of a ceria (CeO2) nanoparticle with electron beam doses of similar to 125-5000 e-angstrom(-2) per frame. The accuracy of the algorithm for locating atomic column positions is compared to that of the more traditional centroid fitting technique, and the accuracy of intensity measurements is evaluated as a function of dose per frame. The code developed here, and the methodology used to explore the errors and limitations of the measurements, could be applied more broadly to any temporally resolved TEM image series to track dynamic atomic column motion.
引用
收藏
页数:11
相关论文
共 40 条
[1]   Cationic Surface Reconstructions on Cerium Oxide Nanocrystals: An Aberration-Corrected HRTEM Study [J].
Bhatta, Umananda M. ;
Ross, Ian M. ;
Sayle, Thi X. T. ;
Sayle, Dean C. ;
Parker, Stephen C. ;
Reid, David ;
Seal, Sudipta ;
Kumar, Amit ;
Moebus, Guenter .
ACS NANO, 2012, 6 (01) :421-430
[2]   Methods of digital video microscopy for colloidal studies [J].
Crocker, JC ;
Grier, DG .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1996, 179 (01) :298-310
[3]   Estimation of unknown structure parameters from high-resolution (S)TEM images: What are the limits? [J].
den Dekker, A. J. ;
Gonnissen, J. ;
De Backer, A. ;
Sijbers, J. ;
Van Aert, S. .
ULTRAMICROSCOPY, 2013, 134 :34-43
[4]   Direct single electron detection with a CMOS detector for electron microscopy [J].
Faruqi, AR ;
Henderson, R ;
Pryddetch, M ;
Allport, P ;
Evans, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 546 (1-2) :170-175
[5]   The maximum a posteriori probability rule for atom column detection from HAADF STEM images [J].
Fatermans, J. ;
Van Aert, S. ;
den Dekker, A. J. .
ULTRAMICROSCOPY, 2019, 201 :81-91
[6]   Adatom dynamics and the surface reconstruction of Si(110) revealed using time-resolved electron microscopy [J].
Furnival, Tom ;
Knez, Daniel ;
Schmidt, Eric ;
Leary, Rowan K. ;
Kothleitner, Gerald ;
Hofer, Ferdinand ;
Bristowe, Paul D. ;
Midgley, Paul A. .
APPLIED PHYSICS LETTERS, 2018, 113 (18)
[7]   Aberration-corrected imaging of active sites on industrial catalyst nanoparticles [J].
Gontard, Lionel Cervera ;
Chang, Lan-Yun ;
Hetherington, Crispin J. D. ;
Kirkland, Angus I. ;
Ozkaya, Dogan ;
Dunin-Borkowski, Rafal E. .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2007, 46 (20) :3683-3685
[8]   A spherical-aberration-corrected 200 kV transmission electron microscope [J].
Haider, M ;
Rose, H ;
Uhlemann, S ;
Schwan, E ;
Kabius, B ;
Urban, K .
ULTRAMICROSCOPY, 1998, 75 (01) :53-60
[9]   Atom-resolved imaging of dynamic shape changes in supported copper nanocrystals [J].
Hansen, PL ;
Wagner, JB ;
Helveg, S ;
Rostrup-Nielsen, JR ;
Clausen, BS ;
Topsoe, H .
SCIENCE, 2002, 295 (5562) :2053-2055
[10]   Observing gas-catalyst dynamics at atomic resolution and single-atom sensitivity [J].
Helveg, S. ;
Kisielowski, C. F. ;
Jinschek, J. R. ;
Specht, P. ;
YuaN, G. ;
Frei, H. .
MICRON, 2015, 68 :176-185