Early Diagnosis of Myocardial Infarction With Point-of-Care High-Sensitivity Cardiac Troponin I

被引:109
|
作者
Boeddinghaus, Jasper [1 ,2 ,3 ]
Nestelberger, Thomas [1 ,2 ,3 ]
Koechlin, Luca [1 ,2 ,3 ,4 ]
Wussler, Desiree [1 ,2 ,3 ,5 ]
Lopez-Ayala, Pedro [1 ,2 ,3 ]
Walter, Joan Elias [1 ,2 ,3 ,5 ]
Troester, Valentina [1 ,2 ,3 ]
Ratmann, Paul David [1 ,2 ,3 ]
Seidel, Funda [1 ,2 ,3 ]
Zimmermann, Tobias [1 ,2 ,3 ,5 ]
Badertscher, Patrick [1 ,2 ,3 ,6 ]
Wildi, Karin [1 ,2 ,3 ,7 ,8 ]
Gimenez, Maria Rubini [1 ,2 ,3 ,9 ]
Potlukova, Eliska [1 ,2 ,3 ,5 ]
Strebel, Ivo [1 ,2 ,3 ]
Freese, Michael [1 ,2 ,3 ]
Miro, Oscar [3 ,10 ]
Javier Martin-Sanchez, F. [3 ,11 ]
Kawecki, Damian [3 ,12 ]
Keller, Dagmar I. [13 ]
Gualandro, Danielle M. [1 ,2 ,3 ,14 ]
Christ, Michael [3 ,15 ]
Twerenbold, Raphael [1 ,2 ,3 ]
Mueller, Christian [1 ,2 ,3 ]
机构
[1] Univ Basel, Univ Hosp Basel, Cardiovasc Res Inst Basel, Basel, Switzerland
[2] Univ Basel, Univ Hosp Basel, Dept Cardiol, Basel, Switzerland
[3] GREAT Network, Rome, Italy
[4] Univ Basel, Univ Hosp Basel, Dept Cardiac Surg, Basel, Switzerland
[5] Univ Basel, Univ Hosp Basel, Div Internal Med, Basel, Switzerland
[6] Med Univ South Carolina, Div Cardiol, Charleston, SC 29425 USA
[7] Prince Charles Hosp, Crit Care Res Grp, Brisbane, Qld, Australia
[8] Univ Queensland, Brisbane, Qld, Australia
[9] Leipzig Heart Ctr, Leipzig, Germany
[10] Hosp Clin Barcelona, Emergency Dept, Barcelona, Catalonia, Spain
[11] Hosp Clin San Carlos, Serv Urgencias, Madrid, Spain
[12] Med Univ Katowice, Dept Cardiol 2, Sch Med, Div Dent Zabrze, Katowice, Poland
[13] Univ Hosp Zurich, Emergency Dept, Zurich, Switzerland
[14] Univ Sao Paulo, Med Sch, Heart Inst InCor, Sao Paulo, Brazil
[15] Kantonsspital Luzern, Emergency Dept, Luzern, Switzerland
基金
瑞士国家科学基金会;
关键词
0/1-h algorithm; diagnosis of myocardial infarction; guidelines; high-sensitivity cardiac troponin I; point of care; rule in; rule out; ACUTE CORONARY SYNDROME; EMERGENCY-DEPARTMENT; RULE-OUT; IMPLEMENTATION; ALGORITHM;
D O I
10.1016/j.jacc.2019.12.065
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Until now, high-sensitivity cardiac troponin (hs-cTn) assays were mainly developed for large central laboratory platforms. OBJECTIVES This study aimed to assess the clinical performance of a point-of-care (POC)-hs-cTnI assay in patients with suspected myocardial infarction (MI). METHODS This study enrolled patients presenting to the emergency department with symptoms suggestive of MI. Two cardiologists centrally adjudicated the final diagnosis using all clinical data including cardiac imaging. The primary objective was to directly compare diagnostic accuracy of POC-hs-cTnI-TriageTrue versus best-validated central laboratory assays. Secondary objectives included the derivation and validation of a POC-hs-cTnI-TriageTrue-specific 0/1-h algorithm. RESULTS MI was the adjudicated final diagnosis in 178 of 1,261 patients (14%). The area under the curve (AUC) for POC-hs-cTnI-TriageTrue at presentation was 0.95 (95% confidence interval [CI]: 0.93 to 0.96) and was at least comparable to hs-cTnT-Elecsys (AUC: 0.94; 95% CI: 0.93 to 0.96; p = 0.213) and hs-cTnI-Architect (AUC: 0.92; 95% CI: 0.90 to 0.93; p < 0.001). A single cutoff concentration <3 ng/l at presentation identified 45% of patients at low risk with a negative predictive value (NPV) of 100% (95% CI: 99.4% to 100%). A single cutoff concentration >60 ng/l identified patients at high risk with a positive predictive value (PPV) of 76.8% (95% CI: 68.9% to 83.6%). The 0/1-h algorithm ruled out 55% of patients (NPV: 100%; 95% CI: 98.8% to 100%), and ruled in 18% of patients (PPV: 76.8%; 95% CI: 67.2% to 84.7%). Ruled-out patients had cumulative event rates of 0% at 30 days and 1.6% at 2 years. This study confirmed these findings in a secondary analysis including hs-cTnI-Architect for central adjudication. CONCLUSIONS The POC-hs-cTnI-TriageTrue assay provides high diagnostic accuracy in patients with suspected MI with a clinical performance that is at least comparable to that of best-validated central laboratory assays. (Advantageous Predictors of Acute Coronary Syndromes Evaluation Study [APACE]; NCT00470587) (C) 2020 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation.
引用
收藏
页码:1111 / 1124
页数:14
相关论文
共 50 条
  • [21] High-sensitivity cardiac troponin and the diagnosis of myocardial infarction in patients with kidney impairment
    Gallacher, Peter J.
    Miller-Hodges, Eve
    Shah, Anoop S., V
    Farrah, Tariq E.
    Halbesma, Nynke
    Blackmur, James P.
    Chapman, Andrew R.
    Adamson, Philip D.
    Anand, Atul
    Strachan, Fiona E.
    Ferry, Amy, V
    Lee, Kuan Ken
    Berry, Colin
    Findlay, Iain
    Cruickshank, Anne
    Reid, Alan
    Gray, Alasdair
    Collinson, Paul O.
    Apple, Fred S.
    McAllister, David A.
    Maguire, Donogh
    Fox, Keith A. A.
    Keerie, Catriona
    Weir, Christopher J.
    Newby, David E.
    Mills, Nicholas L.
    Dhaun, Neeraj
    KIDNEY INTERNATIONAL, 2022, 102 (01) : 149 - 159
  • [22] Point-of-care testing with high-sensitivity cardiac troponin assays: the challenges and opportunities
    Cullen, Louise
    Collinson, Paul O.
    Giannitsis, Evangelos
    EMERGENCY MEDICINE JOURNAL, 2022, 39 (11) : 861 - 866
  • [23] DIRECT COMPARISON OF HIGH-SENSITIVITY CARDIAC TROPONIN I VERSUS CONVENTIONAL TROPONIN I FOR THE EARLY DIAGNOSIS OF NON-ST ELEVATION MYOCARDIAL INFARCTION
    Saifullah, Shabina
    Ehsan, Mian
    Khalid, Salma
    Jehanzeb
    PAKISTAN HEART JOURNAL, 2019, 52 (01): : 4 - 9
  • [24] Point-of-care troponin T is inferior to high-sensitivity troponin T for ruling out acute myocardial infarction in the emergency department
    ter Avest, Ewoud
    Visser, Anniek
    Reitsma, Bram
    Breedveld, Rob
    Wolthuis, Albert
    EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2016, 23 (02) : 95 - 101
  • [25] Diagnostic performance of a rapid, novel, whole blood, point of care high-sensitivity cardiac troponin I assay for myocardial infarction
    Gunsolus, Ian L.
    Schulz, Karen
    Sandoval, Yader
    Smith, Stephen W.
    Lindgren, Brittany
    Okeson, Brynn
    Apple, Fred S.
    CLINICAL BIOCHEMISTRY, 2022, 105 : 70 - 74
  • [26] Comparison of new point-of-care troponin assay with high sensitivity troponin in diagnosing myocardial infarction
    Aldous, Sally
    Richards, A. Mark
    George, Peter M.
    Cullen, Louise
    Parsonage, William A.
    Flaws, Dylan
    Florkowski, Christopher M.
    Troughton, Richard W.
    O'Sullivan, Jack W.
    Reid, Christopher M.
    Bannister, Laura
    Than, Martin
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 177 (01) : 182 - 186
  • [27] High-sensitivity detection of cardiac troponin I with UV LED excitation for use in point-of-care immunoassay
    Rodenko, Olga
    Eriksson, Susann
    Tidemand-Lichtenberg, Peter
    Troldborg, Carl Peder
    Fodgaard, Henrik
    van Os, Sylvana
    Pedersen, Christian
    BIOMEDICAL OPTICS EXPRESS, 2017, 8 (08): : 3749 - 3762
  • [28] Diagnostic accuracy of a novel ultra-sensitive cardiac troponin I assay compared to high-sensitivity cardiac troponin T and I for the early diagnosis of myocardial infarction
    Twerenbold, R.
    Rubini Gimenez, M.
    Boeddinghaus, J.
    Nestelberger, T.
    Puelacher, C.
    Badertscher, P.
    Du Fay De Lavallaz, J.
    Wussler, D.
    Kozhuharov, N.
    Miro, O.
    Martin-Sanchez, F. J.
    Morawiec, B.
    Keller, D.
    Reichlin, T.
    Mueller, C.
    EUROPEAN HEART JOURNAL, 2018, 39 : 552 - 552
  • [29] The combination of creatine kinase-myocardial band isoenzyme and point-of-care cardiac troponin/contemporary cardiac troponin for the early diagnosis of acute myocardial infarction
    Guang-mei Wang
    Yong Li
    Shuo Wu
    Wen Zheng
    Jing-jing Ma
    Feng Xu
    Jia-qi Zheng
    He Zhang
    Jia-li Wang
    Yu-guo Chen
    World Journal of Emergency Medicine, 2022, 13 (03) : 163 - 168
  • [30] The combination of creatine kinase-myocardial band isoenzyme and point-of-care cardiac troponin/contemporary cardiac troponin for the early diagnosis of acute myocardial infarction
    Wang, Guang-mei
    Li, Yong
    Wu, Shuo
    Zheng, Wen
    Ma, Jing-jing
    Xu, Feng
    Zheng, Jia-qi
    Zhang, He
    Wang, Jia-li
    Chen, Yu-guo
    WORLD JOURNAL OF EMERGENCY MEDICINE, 2022, 13 (03) : 163 - 168