Contraction stress and physical properties development of a resin-based composite irradiated using modulated curing methods at two C-factor levels

被引:31
作者
Cunha, Leonardo G. [1 ]
Alonso, Roberta C. B. [1 ]
Pfeifer, Carmern S. C. [2 ]
Correr-Sobrinho, Lourengo [1 ]
Ferracane, Jack L. [3 ]
Sinhoreti, Mario Alexandre C. [1 ]
机构
[1] Univ Estadual Campinas, Dept Restorat Dent, Dent Mat Area, BR-13414018 Piracicaba, SP, Brazil
[2] Univ Sao Paulo, Dept Dent Mat, Sao Paulo, Brazil
[3] Oregon Hlth & Sci Univ, Div Biomat & Biomech, Dept Restorat Dent, Portland, OR 97201 USA
关键词
composite resin; curing method; contraction stress; C-factor; degree of conversion;
D O I
10.1016/j.dental.2007.06.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. The objective of this study was to verify the influence of curing methods on contraction stress, stress rate and degree of conversion (DC) of a restorative composite at two C-factor levels. Methods. For the stress test, composite was applied between two for 15 min from diameter glass rods mounted in a servohydraulic machine, and stress was monitored for 10 min from the beginning of light curing. Stress rates were calculated as the change in stress versus time at each second. DC was measured by micro-FTIR. Four curing methods were tested at two C-factor levels (1.5 and 3.0): continuous light (CL), soft-start (SS) and two pulse delay methods using different initial irradiances-150 mW/cm(2) (PD150) and 80 mW/cm(2) (PD80). Results were analyzed by ANOVA and Tukey's test (alpha = 0.05). Results. For the stress test, at CF 1.5, PD80 presented the lowest mean value, statistically different from the others. PD150 also showed a mean value statistically inferior to CL. At CF 3.0, no statistical difference was observed among CL, SS and PD150. PD80 presented statistically lower stress values compared to CL and SS. Stress values at CF 3.0 were statistically higher than those at CF 1.5 for all curing methods. CL presented the highest maximum stress rate, followed by SS, PD150 and PD80, for both C-factors. In the DC test, no difference was observed among the methods and between the C-factor levels. Significance. Modulated curing methods were shown to be effective in reducing contraction stress rate, without compromising the DC of the restorative composite. C-factor was shown to influence negatively the stress rate and the amount of stress generated. (C) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:392 / 398
页数:7
相关论文
共 30 条
[1]  
Bouschlicher M R, 2000, J Esthet Dent, V12, P328, DOI 10.1111/j.1708-8240.2000.tb00242.x
[2]   Factors involved in the development of polymerization shrinkage stress in resin-composites: A systematic review [J].
Braga, RR ;
Ballester, RY ;
Ferracane, JL .
DENTAL MATERIALS, 2005, 21 (10) :962-970
[3]   Contraction stress related to degree of conversion and reaction kinetics [J].
Braga, RR ;
Ferracane, JL .
JOURNAL OF DENTAL RESEARCH, 2002, 81 (02) :114-118
[4]   Polymerization contraction stress of low-shrinkage composites and its correlation with microleakage in class V restorations [J].
Calheiros, FC ;
Sadek, FT ;
Braga, RR ;
Cardoso, PEC .
JOURNAL OF DENTISTRY, 2004, 32 (05) :407-412
[5]   Polymerization contraction stress in light-cured compomer restorative materials [J].
Chen, HY ;
Manhart, J ;
Kunzelmann, KH ;
Hickel, R .
DENTAL MATERIALS, 2003, 19 (07) :597-602
[6]   SETTING STRESS IN COMPOSITE RESIN IN RELATION TO CONFIGURATION OF THE RESTORATION [J].
FEILZER, AJ ;
DEGEE, AJ ;
DAVIDSON, CL .
JOURNAL OF DENTAL RESEARCH, 1987, 66 (11) :1636-1639
[7]   QUANTITATIVE-DETERMINATION OF STRESS REDUCTION BY FLOW IN COMPOSITE RESTORATIONS [J].
FEILZER, AJ ;
DEGEE, AJ ;
DAVIDSON, CL .
DENTAL MATERIALS, 1990, 6 (03) :167-171
[8]   INFLUENCE OF LIGHT-INTENSITY ON POLYMERIZATION SHRINKAGE AND INTEGRITY OF RESTORATION-CAVITY INTERFACE [J].
FEILZER, AJ ;
DOOREN, LH ;
DEGEE, AJ ;
DAVIDSON, CL .
EUROPEAN JOURNAL OF ORAL SCIENCES, 1995, 103 (05) :322-326
[9]   INCREASED WALL-TO-WALL CURING CONTRACTION IN THIN BONDED RESIN LAYERS [J].
FEILZER, AJ ;
DEGEE, AJ ;
DAVIDSON, CL .
JOURNAL OF DENTAL RESEARCH, 1989, 68 (01) :48-50
[10]  
Gordan Valeria V, 2006, J Esthet Restor Dent, V18, P144, DOI 10.1111/j.1708-8240.2006.00007.x