Analytical study and design approach of the axial and flexural response of reinforced masonry columns confined with FRP jackets

被引:4
|
作者
Alotaibi, Khalid Saqer [1 ]
AbdelRahman, Belal [2 ,3 ]
Galal, Khaled [4 ]
机构
[1] Imam Abdulrahman Bin Faisal Univ, Coll Engn, Dept Civil & Construct Engn, Dammam 31451, Saudi Arabia
[2] Concordia Univ, Dept Bldg Civil & Environm Engn, Montreal, PQ H3G 2W1, Canada
[3] Cairo Univ, Fac Engn, Dept Struct Engn, Giza, Egypt
[4] Concordia Univ, Dept Bldg Civil & Environm Engn, Montreal, PQ H3G 2W1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Concrete masonry blocks; Confinement; Eccentric loading; Fiber-reinforced polymer (FRP); Interaction diagram; Reinforced masonry columns; Retrofitting; STRESS-STRAIN RELATIONSHIP; CONCRETE COLUMNS; COMPRESSIVE BEHAVIOR; LOAD;
D O I
10.1016/j.engstruct.2022.114805
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Using fiber-reinforced polymer (FRP) wraps has proven to be an effective and optimized confinement technique to upgrade the axial and flexural capacity of reinforced concrete (RC) and reinforced masonry (RM) columns. The axial capacity of FRP-confined masonry depends on both the compressive strength of masonry before strengthening and the confinement pressure provided by the FRP jacket. This study proposes a simplified methodology to design and analyze prismatic fully grouted reinforced masonry columns (RMCs) strengthened with FRP Jackets. The proposed design methodology included an analytical confinement model to predict the compressive strength gain in RMCs due to the effective confinement pressure provided by FRP jackets. The proposed procedure was also designed to predict the nominal capacity of RMCs for practical design applications, with columns subjected to both axial loading and bending moment. The essential parameters to perform detailed section analysis were established, and suggested expressions were proposed to obtain the parameter values. Practical values for the equivalent rectangular stress block parameters were proposed. The theoretical axial force -moment interaction diagrams obtained by the proposed procedure were compared with available experimental data. The experimental test results were in good agreement with the analytical predictions by a reasonable marginal error. Furthermore, the effect of five design variables on the axial-flexural interaction of FRP-wrapped RMCs was investigated. The variables considered in the parametric study were the number of FRP layers, radius of the corners, stiffness of the FRP composite, cross-sectional aspect ratio, and masonry compressive strength. The results showed that increasing the FRP layers, corner radius, and FRP jacket stiffness significantly enhanced the axial capacity of the FRP-confined RMCs. However, the increase in the masonry compressive strength and cross-sectional aspect ratio negatively affected the axial capacity gain ratio of FRP-strengthened RMCs.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Axial-Flexural Interaction for FRP-Confined Reinforced Masonry Columns
    Alotaibi, Khalid Saqer
    AbdelRahman, Belal
    Galal, Khaled
    International Conference on Structural Health Monitoring of Intelligent Infrastructure: Transferring Research into Practice, SHMII, 2022, 2022-August : 441 - 444
  • [2] Axial behavior of reinforced concrete columns confined with FRP jackets
    Pessiki, S
    Harries, KA
    Kestner, JT
    Sause, R
    Ricles, JM
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2001, 5 (04) : 237 - 245
  • [3] Axial-flexural interaction in circular FRP-confined reinforced concrete columns
    Bisby, Luke
    Ranger, Michael
    CONSTRUCTION AND BUILDING MATERIALS, 2010, 24 (09) : 1672 - 1681
  • [4] Axial compressive behavior of grouted concrete block masonry columns confined by CFRP jackets
    Alotaibi, Khalid Saqer
    Galal, Khaled
    COMPOSITES PART B-ENGINEERING, 2017, 114 : 467 - 479
  • [5] Compressive Behavior of Brick Masonry Columns Confined with Steel-Reinforced Grout Jackets
    Sneed, Lesley H.
    Baietti, Giulia
    Fraioli, Giacomo
    Carloni, Christian
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2019, 23 (05)
  • [6] Displacement-based seismic design of reinforced concrete columns strengthened by FRP jackets using a nonlinear flexural model
    Cho, Chang-Geun
    Yun, Hee-Cheon
    Kim, Yun-Yong
    COMPUTERS AND CONCRETE, 2009, 6 (02): : 95 - 108
  • [7] Analytical model for FRP-confined circular reinforced concrete columns
    Eid, R.
    Paultre, P.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2008, 12 (05) : 541 - 552
  • [8] Axial-flexural performance of columns reinforced by steel-FRP composite bars and FRP ties
    Han, Shiwen
    Zhou, Ao
    Fan, Chao
    Xiao, Gang
    Ou, Jinping
    COMPOSITE STRUCTURES, 2023, 322
  • [9] Axial and flexural behavior of unreinforced and FRP bar reinforced circular concrete filled FRP tube columns
    Hadi, Muhammad N. S.
    Khan, Qasim S.
    Sheikh, M. Neaz
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 122 : 43 - 53
  • [10] Simplified design equations for reinforced concrete columns confined with FRP wraps
    Thériault, M
    Neale, KW
    FRP COMPOSITES IN CIVIL ENGINEERING, VOLS I AND II, PROCEEDINGS, 2001, : 741 - 748