The redesigned follitropin alfa pen injector: results of the patient and nurse human factors usability testing

被引:19
|
作者
Schertz, Joan C. [1 ]
Saunders, Helen [2 ]
Hecker, Clara [3 ]
Lang, Barbara [3 ]
Arriagada, Pablo [4 ]
机构
[1] EMD Serono Inc, Fertil Global Clin Dev Unit, Rockland, MA 02370 USA
[2] Merck Serono SA, Fertil & Endocrinol Global Clin Dev Unit, Geneva, Switzerland
[3] Point Blank Int Mkt Res & Consultancy GmbH, Berlin, Germany
[4] Merck Serono SA, Fertil Global Clin Dev Unit Global Med Affairs, Geneva, Switzerland
关键词
follitropin alpha; human factors; in vitro fertilization; infertility; injection device; pen injector; recombinant human follicle-stimulating hormone; usability testing; OVULATION INDUCTION; DEVICE; DRUGS; WOMEN;
D O I
10.1517/17425247.2011.608350
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Objectives: A redesigned pen injector for administration of follitropin alfa (follitropin alpha) has been developed for use in fertility treatment cycles. Pre-summative and summative usability testing was undertaken to assess the risk of dosing errors compared with the existing follitropin a pen. The study also assessed proper use of and dose selection with the redesigned pen. Methods: Infertile women who were trying to conceive and specialist nurses were recruited from four cities in Germany. Usability goals relating to proper use of the pen device were defined from a risk assessment and further categorized as critical and functional operational goals. Individual, non-interventional, standardized, usability tests were performed with patients and nurses by four experienced research professionals using questionnaires that also included ease-of-use ratings. A non-standardized qualitative analysis of nurse-patient training sessions was performed in the presence of a research professional; reasons for confidence, safety, possible misunderstandings and risks when handling the pen were noted. Results: The overall risk of dosing errors with the redesigned pen was not higher than with the existing pen. No unexpected operational risks and no major concerns regarding the risk of misuse or dosing errors were identified. Conclusions: The study provides useful practical information on the redesigned pen from both patient and nurse perspectives.
引用
收藏
页码:1111 / 1120
页数:10
相关论文
共 23 条
  • [21] Human Factors for Nursing: From In-Situ Testing to Mobile Usability Engineering
    Kushniruk, Andre W.
    Borycki, Elizabeth M.
    Solvoll, Terje
    Hullin, Carola
    NURSING INFORMATICS 2016: EHEALTH FOR ALL: EVERY LEVEL COLLABORATION - FROM PROJECT TO REALIZATION, 2016, 225 : 689 - 691
  • [22] Investigation of the Human Factors, Usability and User Experience of Patient Monitors used in a Hospital Setting
    Andrade, Evismar
    Quinlan, Leo R.
    Harte, Richard
    Byrne, Dara
    Fallon, Enda
    Kelly, Martina
    O'Connor, Paul
    O'Hora, Denis
    Scully, Michael
    Laffey, John
    Pladys, Patrick
    Beuchee, Alain
    OLaighin, Gearoid
    HUMAN SYSTEMS ENGINEERING AND DESIGN, IHSED2018, 2019, 876 : 352 - 357
  • [23] Augmenting Critical Care Patient Monitoring Using Wearable Technology: Review of Usability and Human Factors
    Andrade, Evismar
    Quinlan, Leo
    Harte, Richard
    Byrne, Dara
    Fallon, Enda
    Kelly, Martina
    Casey, Siobhan
    Kirrane, Frank
    O'Connor, Paul
    O'Hora, Denis
    Scully, Michael
    Laffey, John
    Pladys, Patrick
    Beuchee, Alain
    OLaighin, Gearoid
    JMIR HUMAN FACTORS, 2021, 8 (02):