Agreement of Bioreactance Cardiac Output Monitoring With Thermodilution During Hemorrhagic Shock and Resuscitation in Adult Swine

被引:5
作者
Berlin, David A. [1 ]
Peprah-Mensah, Harrison [2 ]
Manoach, Seth [1 ]
Heerdt, Paul M. [3 ]
机构
[1] Weill Cornell Med, Dept Med, New York, NY USA
[2] Weill Cornell Med, Dept Anesthesiol, New York, NY USA
[3] Yale Univ, Sch Med, New Haven, CT 06520 USA
关键词
bioreactance; cardiac output; hemorrhagic shock; stroke volume; thermodilution;
D O I
10.1097/CCM.0000000000002071
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: The study tests the hypothesis that noninvasive cardiac output monitoring based upon bioreactance (Cheetah Medical, Portland, OR) has acceptable agreement with intermittent bolus thermodilution over a wide range of cardiac output in an adult porcine model of hemorrhagic shock and resuscitation. Design: Prospective laboratory animal investigation. Setting: Preclinical university laboratory. Subjects: Eight similar to 50 kg Yorkshire swine with a femoral artery catheter for blood pressure measurement and a pulmonary artery catheter for bolus thermodilution. Interventions: With the pigs anesthetized and mechanically ventilated, 40 mL/kg of blood was removed yielding marked hypotension and a rise in plasma lactate. After 60 minutes, pigs were resuscitated with shed blood and crystalloid. Noninvasive cardiac output monitoring and intermittent thermodilution cardiac output were simultaneously measured at nine time points spanning baseline, hemorrhage, and resuscitation. Measurements and Main Results: Simultaneous noninvasive cardiac output monitoring and thermodilution measurements of cardiac output were compared by Bland-Altman analysis. A plot was constructed using the difference of each paired measurement expressed as a percentage of the mean of the pair plotted against the mean of the pair. Percent bias was used to scale the differences in the measurements for the magnitude of the cardiac output. Method concordance was assessed from a four-quadrant plot with a 15% zone of exclusion. Overall, noninvasive cardiac output monitoring percent bias was 1.47% (95% CI, -2.5 to 5.4) with limits of agreement of upper equal to 33.4% (95% CI, 26.5-40.2) and lower equal to -30.4% (95% CI, -37.3 to -23.6). Trending analysis demonstrated a 97% concordance between noninvasive cardiac output monitoring and thermodilution cardiac output. Conclusions: Over the wide range of cardiac output produced by hemorrhage and resuscitation in large pigs, noninvasive cardiac output monitoring has acceptable agreement with thermodilution cardiac output.
引用
收藏
页码:E195 / E201
页数:7
相关论文
共 23 条
[1]   Pulmonary arterial thermodilution, femoral arterial thermodilution and bioreactance cardiac output monitoring in a pediatric hemorrhagic hypovolemic shock model [J].
Ballestero, Yolanda ;
Urbano, Javier ;
Lopez-Herce, Jesus ;
Solana, Maria J. ;
Botran, Marta ;
Vinciguerra, Diego ;
Bellon, Jose M. .
RESUSCITATION, 2012, 83 (01) :125-129
[2]   COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[3]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine [J].
Cecconi, Maurizio ;
De Backer, Daniel ;
Antonelli, Massimo ;
Beale, Richard ;
Bakker, Jan ;
Hofer, Christoph ;
Jaeschke, Roman ;
Mebazaa, Alexandre ;
Pinsky, Michael R. ;
Teboul, Jean Louis ;
Vincent, Jean Louis ;
Rhodes, Andrew .
INTENSIVE CARE MEDICINE, 2014, 40 (12) :1795-1815
[6]   Bench-to-bedside review: The importance of the precision of the reference technique in method comparison studies - with specific reference to the measurement of cardiac output [J].
Cecconi, Maurizio ;
Rhodes, Andrew ;
Poloniecki, Jan ;
Della Rocca, Giorgio ;
Grounds, R. Michael .
CRITICAL CARE, 2009, 13 (01)
[7]   A Critical Review of the Ability of Continuous Cardiac Output Monitors to Measure Trends in Cardiac Output [J].
Critchley, Lester A. ;
Lee, Anna ;
Ho, Anthony M. -H. .
ANESTHESIA AND ANALGESIA, 2010, 111 (05) :1180-1192
[8]   In emergently ventilated trauma patients, low end-tidal CO2 and low cardiac output are associated and correlate with hemodynamic instability, hemorrhage, abnormal pupils, and death [J].
Dunham, C. Michael ;
Chirichella, Thomas J. ;
Gruber, Brian S. ;
Ferrari, Jonathan P. ;
Martin, Joseph A. ;
Luchs, Brenda A. ;
Hileman, Barbara M. ;
Merrell, Renee .
BMC ANESTHESIOLOGY, 2013, 13
[9]   Understanding Bland Altman analysis [J].
Giavarina, Davide .
BIOCHEMIA MEDICA, 2015, 25 (02) :141-151
[10]  
Hall Critchley LA, 2013, ARTERY BYPASS, P45