Degradation of condensation heat transfer on a vertical cylinder by a light noncondensable gas mixed with air-steam mixtures

被引:16
作者
Park, Il Woong [1 ]
Yang, Si Hyuk [2 ]
Lee, Yeon-Gun [2 ]
机构
[1] Jeju Natl Univ, Inst Nucl Sci & Technol, 102 Jejudaehak Ro, Jeju Si 63243, Jeju, South Korea
[2] Jeju Natl Univ, Dept Nucl & Energy Engn, 102 Jejudaehak Ro, Jeju Si 63243, Jeju, South Korea
基金
新加坡国家研究基金会;
关键词
Steam condensation; Effect of hydrogen; Natural convection; Steam-air-helium mixture; Degradation factor; CONTAINMENT; RATES; TUBE;
D O I
10.1016/j.icheatmasstransfer.2021.105779
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, the experimental investigation result of steam condensation on a vertical tube in the presence of air and a light noncondensable gas is presented. This study aims at elucidating the effect of hydrogen that may be generated during the progression of a severe accident on the condensation heat transfer. Using helium as a simulant of hydrogen, a series of condensation tests were performed. A novel helium measurement system was introduced to analyze the composition of mixture gas. The condensation heat transfer coefficient was obtained under natural convection conditions on a 1 m long condenser tube having an outer diameter of 21.5 mm. A comprehensive experimental database was obtained to understand the parametric effect of the total mass fraction of noncondensable gases, molar concentration of helium in noncondensable gases, and wall subcooling degree. An empirical correlation for the degradation factor to account for the effect of a light noncondensable gas was proposed for application to the condensation model for the steam-air mixture based on the experimental data. The strategy to adopt the degradation factor was assessed against three steam-air-helium condensation tests.
引用
收藏
页数:10
相关论文
共 33 条
  • [11] DEVELOPMENT OF THE SPACE CODE FOR NUCLEAR POWER PLANTS
    Ha, Sang Jun
    Park, Chan Eok
    Kim, Kyung Doo
    Ban, Chang Hwan
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2011, 43 (01) : 45 - 62
  • [12] A diffusion layer model for steam condensation within the AP600 containment
    Herranz, LE
    Anderson, MH
    Corradini, ML
    [J]. NUCLEAR ENGINEERING AND DESIGN, 1998, 183 (1-2) : 133 - 150
  • [13] An Experimental Study on the Cooling Characteristics of Passive Containment Cooling Systems
    Kawakubo, Masahiro
    Aritomi, Masanori
    Kikura, Hiroshige
    Komeno, Toshihiro
    [J]. JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2009, 46 (04) : 339 - 345
  • [14] Kim B.J., 2019, P 18 INT TOP M NUCL
  • [15] Measurement of heat transfer coefficients for steam condensation on a vertical 21.5-mm-OD tube in the presence of air
    Kim, Un-Ki
    Yoo, Ji-Woong
    Jang, Yeong-Jun
    Lee, Yeon-Gun
    [J]. JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2020, 57 (08) : 905 - 916
  • [16] An investigation of condensation from steam-gas mixtures flowing downward inside a vertical tube
    Kuhn, SZ
    Schrock, VE
    Peterson, PF
    [J]. NUCLEAR ENGINEERING AND DESIGN, 1997, 177 (1-3) : 53 - 69
  • [17] The concept of the innovative power reactor
    Lee, Sang Won
    Heo, Sun
    Ha, Hui Un
    Kim, Han Gon
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2017, 49 (07) : 1431 - 1441
  • [18] Analysis of air-steam condensation tests on a vertical tube of the passive containment cooling system under natural convection
    Lee, Yeon-Gun
    Jang, Yeong-Jun
    Kim, Sin
    [J]. ANNALS OF NUCLEAR ENERGY, 2019, 131 : 460 - 474
  • [19] An experimental study of air-steam condensation on the exterior surface of a vertical tube under natural convection conditions
    Lee, Yeon-Gun
    Jang, Yeong-Jun
    Choi, Dong-Jae
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 104 : 1034 - 1047
  • [20] Development of stability maps for flashing-induced instability in a passive containment cooling system for iPOWER
    Lim, Sang Gyu
    No, Hee Cheon
    Lee, Sang Won
    Kim, Han Gon
    Cheon, Jong
    Lee, Jae Min
    Ohk, Seung Min
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2020, 52 (01) : 37 - 50