Development of a rapid and sensitive electrochemical biosensor for detection of human norovirus via novel specific binding peptides

被引:77
作者
Baek, Seung Hoon [1 ]
Kim, Min Woo [1 ]
Park, Chan Yeong [1 ]
Choi, Chang-Sun [2 ]
Kailasa, Suresh Kumar [1 ,4 ]
Park, Jong Pil [3 ]
Park, Tae Jung [1 ]
机构
[1] Chung Ang Univ, Res Inst Halal Ind Technol, Inst Interdisciplinary Convergence Res, Dept Chem, 84 Heukseok Ro, Seoul 06974, South Korea
[2] Chung Ang Univ, Sch Food Sci & Technol, Dept Food & Nutr, Ansung 17546, South Korea
[3] Daegu Haany Univ, Dept Pharmaceut Engn, Gyongsan 38610, South Korea
[4] SV Natl Inst Technol, Dept Appl Chem, Surat 395007, Gujarat, India
关键词
Human norovirus; Specific binding peptides; Biosensor; Electrochemical impedance spectroscopy; MURINE NOROVIRUS; FECAL SPECIMENS; GOLD; GASTROENTERITIS; AMPLIFICATION; ELECTRODES; DIAGNOSIS; LINKERS; APTAMER; OYSTERS;
D O I
10.1016/j.bios.2018.08.064
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Human noroviruses cause acute foodbome gastroenteritis outbreaks worldwide. In this study, a highly sensitive and selective electrochemical biosensor was fabricated for the detection of human norovirus using novel peptides as recognition elements. The electrochemical biosensor was fabricated by assembling of eight novel peptides separately on the gold electrode and investigated their efficiencies for sensing human noroviruses. Among eight peptides, NoroBP peptide coated onto the gold electrode exhibited a high binding affinity towards human noroviruses, resulting a progressive decrease in current signals with increasing concentration of human norovirus (0-10(5) copies/mL). As a result, NoroBP-nonFoul(FlexL)(2)-coated gold electrode acts an efficient electrochemical biosensor for highly selective detection of human norovirus with a detection limit of 1.7 copies/mL, which is 3-fold lower than the reported methods. The developed electrochemical biosensor was successfully applied to detect human norovirus prepared by standard procedure from oyster, which suggests that the developed biosensor can be used as a very sensitive and selective point-of-care bioanalytical platform for the detection of human norovirus in various food samples.
引用
收藏
页码:223 / 229
页数:7
相关论文
共 38 条
  • [1] An ultrasensitive SiO2-encapsulated alloyed CdZnSeS quantum dot-molecular beacon nanobiosensor for norovirus
    Adegoke, Oluwasesan
    Seo, Min-Woong
    Kato, Tatsuya
    Kawahito, Shoji
    Park, Enoch Y.
    [J]. BIOSENSORS & BIOELECTRONICS, 2016, 86 : 135 - 142
  • [2] Design of the linkers which effectively separate domains of a bifunctional fusion protein
    Arai, R
    Ueda, H
    Kitayama, A
    Kamiya, N
    Nagamune, T
    [J]. PROTEIN ENGINEERING, 2001, 14 (08): : 529 - 532
  • [3] Detection of norovirus virus-like particles using a surface plasmon resonance-assisted fluoroimmunosensor optimized for quantum dot fluorescent labels
    Ashiba, Hiroki
    Sugiyama, Yuki
    Wang, Xiaomin
    Shirato, Haruko
    Higo-Moriguchi, Kyoko
    Taniguchi, Koki
    Ohki, Yoshimichi
    Fujimaki, Makoto
    [J]. BIOSENSORS & BIOELECTRONICS, 2017, 93 : 260 - 266
  • [4] Rapid and sensitive detection of norovirus antibodies in human serum with a biolayer interferometry biosensor
    Auer, Sanna
    Koho, Tiia
    Uusi-Kerttula, Hanni
    Vesikari, Timo
    Blazevic, Vesna
    Hytonen, Vesa P.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 : 507 - 514
  • [5] Colorimetric Detection of Norovirus in Oyster Samples through DNAzyme as a Signaling Probe
    Batule, Bhagwan S.
    Kim, Seong U.
    Mun, Hyoyoung
    Choi, Changsun
    Shim, Won-Bo
    Kim, Min-Gon
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2018, 66 (11) : 3003 - 3008
  • [6] Selection of a DNA aptamer against norovirus capsid protein VP1
    Beier, Rico
    Pahlke, Claudia
    Quenzel, Philipp
    Henseleit, Anja
    Boschke, Elke
    Cuniberti, Gianaurelio
    Labudde, Dirk
    [J]. FEMS MICROBIOLOGY LETTERS, 2014, 351 (02) : 162 - 169
  • [7] Microfluidic platform integrated with graphene-gold nano-composite aptasensor for one-step detection of norovirus
    Chand, Rohit
    Neethirajan, Suresh
    [J]. BIOSENSORS & BIOELECTRONICS, 2017, 98 : 47 - 53
  • [8] The microfluidic chip module for the detection of murine norovirus in oysters using charge switchable micro-bead beating
    Chung, Sung Hee
    Baek, Changyoon
    Cong, Vu Tan
    Min, Junhong
    [J]. BIOSENSORS & BIOELECTRONICS, 2015, 67 : 625 - 633
  • [9] Graphene-based screen-printed electrochemical (bio)sensors and their applications: Efforts and criticisms
    Cinti, Stefano
    Arduini, Fabiana
    [J]. BIOSENSORS & BIOELECTRONICS, 2017, 89 : 107 - 122
  • [10] Diagnosis of Norovirus outbreaks by commercial ELISA or RT-PCR
    de Bruin, Erwin
    Duizer, Erwin
    Vennema, Harry
    Koopmans, Marion P. G.
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2006, 137 (02) : 259 - 264