Development of a rapid and sensitive electrochemical biosensor for detection of human norovirus via novel specific binding peptides

被引:85
作者
Baek, Seung Hoon [1 ]
Kim, Min Woo [1 ]
Park, Chan Yeong [1 ]
Choi, Chang-Sun [2 ]
Kailasa, Suresh Kumar [1 ,4 ]
Park, Jong Pil [3 ]
Park, Tae Jung [1 ]
机构
[1] Chung Ang Univ, Res Inst Halal Ind Technol, Inst Interdisciplinary Convergence Res, Dept Chem, 84 Heukseok Ro, Seoul 06974, South Korea
[2] Chung Ang Univ, Sch Food Sci & Technol, Dept Food & Nutr, Ansung 17546, South Korea
[3] Daegu Haany Univ, Dept Pharmaceut Engn, Gyongsan 38610, South Korea
[4] SV Natl Inst Technol, Dept Appl Chem, Surat 395007, Gujarat, India
关键词
Human norovirus; Specific binding peptides; Biosensor; Electrochemical impedance spectroscopy; MURINE NOROVIRUS; FECAL SPECIMENS; GOLD; GASTROENTERITIS; AMPLIFICATION; ELECTRODES; DIAGNOSIS; LINKERS; APTAMER; OYSTERS;
D O I
10.1016/j.bios.2018.08.064
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Human noroviruses cause acute foodbome gastroenteritis outbreaks worldwide. In this study, a highly sensitive and selective electrochemical biosensor was fabricated for the detection of human norovirus using novel peptides as recognition elements. The electrochemical biosensor was fabricated by assembling of eight novel peptides separately on the gold electrode and investigated their efficiencies for sensing human noroviruses. Among eight peptides, NoroBP peptide coated onto the gold electrode exhibited a high binding affinity towards human noroviruses, resulting a progressive decrease in current signals with increasing concentration of human norovirus (0-10(5) copies/mL). As a result, NoroBP-nonFoul(FlexL)(2)-coated gold electrode acts an efficient electrochemical biosensor for highly selective detection of human norovirus with a detection limit of 1.7 copies/mL, which is 3-fold lower than the reported methods. The developed electrochemical biosensor was successfully applied to detect human norovirus prepared by standard procedure from oyster, which suggests that the developed biosensor can be used as a very sensitive and selective point-of-care bioanalytical platform for the detection of human norovirus in various food samples.
引用
收藏
页码:223 / 229
页数:7
相关论文
共 38 条
[1]   An ultrasensitive SiO2-encapsulated alloyed CdZnSeS quantum dot-molecular beacon nanobiosensor for norovirus [J].
Adegoke, Oluwasesan ;
Seo, Min-Woong ;
Kato, Tatsuya ;
Kawahito, Shoji ;
Park, Enoch Y. .
BIOSENSORS & BIOELECTRONICS, 2016, 86 :135-142
[2]   Design of the linkers which effectively separate domains of a bifunctional fusion protein [J].
Arai, R ;
Ueda, H ;
Kitayama, A ;
Kamiya, N ;
Nagamune, T .
PROTEIN ENGINEERING, 2001, 14 (08) :529-532
[3]   Detection of norovirus virus-like particles using a surface plasmon resonance-assisted fluoroimmunosensor optimized for quantum dot fluorescent labels [J].
Ashiba, Hiroki ;
Sugiyama, Yuki ;
Wang, Xiaomin ;
Shirato, Haruko ;
Higo-Moriguchi, Kyoko ;
Taniguchi, Koki ;
Ohki, Yoshimichi ;
Fujimaki, Makoto .
BIOSENSORS & BIOELECTRONICS, 2017, 93 :260-266
[4]   Rapid and sensitive detection of norovirus antibodies in human serum with a biolayer interferometry biosensor [J].
Auer, Sanna ;
Koho, Tiia ;
Uusi-Kerttula, Hanni ;
Vesikari, Timo ;
Blazevic, Vesna ;
Hytonen, Vesa P. .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 :507-514
[5]   Colorimetric Detection of Norovirus in Oyster Samples through DNAzyme as a Signaling Probe [J].
Batule, Bhagwan S. ;
Kim, Seong U. ;
Mun, Hyoyoung ;
Choi, Changsun ;
Shim, Won-Bo ;
Kim, Min-Gon .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2018, 66 (11) :3003-3008
[6]   Selection of a DNA aptamer against norovirus capsid protein VP1 [J].
Beier, Rico ;
Pahlke, Claudia ;
Quenzel, Philipp ;
Henseleit, Anja ;
Boschke, Elke ;
Cuniberti, Gianaurelio ;
Labudde, Dirk .
FEMS MICROBIOLOGY LETTERS, 2014, 351 (02) :162-169
[7]   Microfluidic platform integrated with graphene-gold nano-composite aptasensor for one-step detection of norovirus [J].
Chand, Rohit ;
Neethirajan, Suresh .
BIOSENSORS & BIOELECTRONICS, 2017, 98 :47-53
[8]   The microfluidic chip module for the detection of murine norovirus in oysters using charge switchable micro-bead beating [J].
Chung, Sung Hee ;
Baek, Changyoon ;
Cong, Vu Tan ;
Min, Junhong .
BIOSENSORS & BIOELECTRONICS, 2015, 67 :625-633
[9]   Graphene-based screen-printed electrochemical (bio)sensors and their applications: Efforts and criticisms [J].
Cinti, Stefano ;
Arduini, Fabiana .
BIOSENSORS & BIOELECTRONICS, 2017, 89 :107-122
[10]   Diagnosis of Norovirus outbreaks by commercial ELISA or RT-PCR [J].
de Bruin, Erwin ;
Duizer, Erwin ;
Vennema, Harry ;
Koopmans, Marion P. G. .
JOURNAL OF VIROLOGICAL METHODS, 2006, 137 (02) :259-264