Flow cytometry-based evaluation of the bacterial removal efficiency of a blackwater reuse treatment plant and the microbiological changes in the associated non-potable distribution network

被引:17
作者
Whitton, Rachel [1 ]
Fane, Sarah [1 ]
Jarvis, Peter [1 ]
Tupper, Martyn [2 ]
Raffin, Marie [2 ]
Coulon, Frederic [1 ]
Nocker, Andreas [1 ,3 ]
机构
[1] Cranfield Univ, Sch Water Energy & Environm, Cranfield MK43 0AL, Beds, England
[2] Thames Water Util Ltd, Clearwater Court, Vastern Rd, Reading RG1 8DB, Berks, England
[3] IWW Water Ctr, Moritzstr 26, D-45476 Mulheim, Germany
关键词
Blackwater reuse; Water recycling; MBR; Distribution system; Chlorination; Flow cytometry; MEMBRANE BIOREACTORS; DISTRIBUTION-SYSTEMS; WATER; CHLORINE; COUNTS; MBR;
D O I
10.1016/j.scitotenv.2018.07.121
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The study evaluated the changes in bacterial numbers across a full-scale membrane bioreactor (MBR) blackwater reuse system. Flow cytometry was used to quantify total and intact bacterial concentrations across the treatment train and during distribution of the recycled water. Membrane passage reduced bacterial numbers by up to 5-log units resulting in coliform-free permeate. A 2-log increase in bacterial cell concentration was subsequently observed after the granular activated carbon unit followed by a reduction in intact cells after chlorination, which corresponds to an overall intact bacteria removal of 3.4-log units. In the distribution network, the proportion of intact cells greatly depended on the free chlorine residual, with decreasing residual enabling regrowth. An initial target of 0.5 mg L-1 free chlorine ensured sufficient suppression of intact cells for up to 14 days (setting the time intervals for system flushes at times of low water usage). Bacterial regrowth was only observed when the free chlorine concentration was below 0.34 mg L-1. Such loss of residual chlorine mainly applied to distant points in the distribution network from the blackwater reuse treatment plant (BRTP). Flushing these network points for 5 min did not substantially reduce cell numbers. At points closer to the BRTP, on the other hand, flushing reduced cell numbers by up to 1.5-log units concomitant with a decreasing proportion of intact cells. Intact cell concentrations did not correlate with DOC, total nitrogen, or soluble reactive phosphate, but it was shown that dead biomass could be efficiently converted into new biomass within seven days. (c) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:1620 / 1629
页数:10
相关论文
共 40 条
[31]   Monitoring microbiological changes in drinking water systems using a fast and reproducible flow cytometric method [J].
Prest, E. I. ;
Hammes, F. ;
Kotzsch, S. ;
van Loosdrecht, M. C. M. ;
Vrouwenvelder, J. S. .
WATER RESEARCH, 2013, 47 (19) :7131-7142
[32]   Bacteriophage removal in a full-scale membrane bioreactor (MBR) - Implications for wastewater reuse [J].
Purnell, Sarah ;
Ebdon, James ;
Buck, Austen ;
Tupper, Martyn ;
Taylor, Huw .
WATER RESEARCH, 2015, 73 :109-117
[33]  
Quevauviller P., 2007, Wastewater Quality Monitoring and Treatment
[34]   Kinetics of membrane damage to high (HNA) and low (LNA) nucleic acid bacterial clusters in drinking water by ozone, chlorine, chlorine dioxide, monochloramine, ferrate(VI), and permanganate [J].
Ramseier, Maaike K. ;
von Gunten, Urs ;
Freihofer, Pietro ;
Hammes, Frederik .
WATER RESEARCH, 2011, 45 (03) :1490-1500
[35]   Public perceptions of recycled water: a survey of visitors to the London 2012 Olympic Park [J].
Smith, H. M. ;
Rutter, P. ;
Jeffrey, P. .
JOURNAL OF WATER REUSE AND DESALINATION, 2015, 5 (02) :189-195
[36]   Necrotrophic growth of Legionella pneumophila [J].
Temmerman, R. ;
Vervaeren, H. ;
Noseda, B. ;
Boon, N. ;
Verstraete, W. .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2006, 72 (06) :4323-4328
[37]  
U.S. Environmental Protection Agency, 2004, Guidelines for water reuse.
[38]   Rapid and direct estimation of active biomass on granular activated carbon through adenosine tri-phosphate (ATP) determination [J].
Velten, Silvana ;
Hammes, Frederik ;
Boller, Markus ;
Egli, Thomas .
WATER RESEARCH, 2007, 41 (09) :1973-1983
[39]   Performance of a full-scale membrane bioreactor system in treating municipal wastewater for reuse purposes [J].
Zanetti, Franca ;
De Luca, Giovanna ;
Sacchetti, Rossella .
BIORESOURCE TECHNOLOGY, 2010, 101 (10) :3768-3771
[40]   Comparison of bacterial regrowth in distribution systems using free chlorine and chloramine: a statistical study of causative factors [J].
Zhang, WD ;
DiGiano, FA .
WATER RESEARCH, 2002, 36 (06) :1469-1482