Tracking radiometric responsivity of optical sensors without on-board calibration systems-case of the Chinese HJ-1A/1B CCD sensors

被引:20
|
作者
Li, Jian [1 ]
Chen, Xiaoling [1 ]
Tian, Liqiao [1 ]
Feng, Lian [1 ]
机构
[1] Wuhan Univ, State Key Lab Informat Engn Surveying Mapping & R, Wuhan 430079, Peoples R China
来源
OPTICS EXPRESS | 2015年 / 23卷 / 02期
基金
中国国家自然科学基金;
关键词
NEAR-INFRARED CHANNELS; RESOLUTION IMAGING SPECTRORADIOMETER; VICARIOUS CALIBRATION; CROSS-CALIBRATION; AEROSOL PROPERTIES; SATELLITE CCD; MODIS; VALIDATION; RETRIEVALS; BRDF;
D O I
10.1364/OE.23.001829
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The radiometric stability of satellite sensors is crucial for generating highly consistent remote sensing measurements and products. We have presented a radiometric responsivity tracking method designed especially for optical sensors without on-board calibration systems. Using a temporally stable desert site with high reflectance, the sensor responsivity was simulated using the Second Simulation of the Satellite Signal in the Solar Spectrum (6S) radiative transfer model (RTM) with information from validated MODIS atmospheric data. Next, radiometric responsivity drifting was identified using a linear regression of the time series bidirectional reflectance distribution function (BRDF) normalized coefficients. The proposed method was applied to Chinese HJ-1A/1B charge-coupled device (CCD) sensors, which have been on-orbit operations for more than 5 years without continuous assessment of their radiometric performance. Results from the Dunhuang desert site between 2008 and 2013 indicated that the CCD sensors degraded at various rates, with the most significant degradation occurring in the blue bands, ranging from 2.8% to 4.2% yr(-1). The red bands were more stable, with a degradation rate of 0.7-3.1% yr(-1). A cross-sensor comparison revealed the least degradation for the HJ-1A CCD1 (blue: 2.8%; green: 2.8%; red: 0.7%; and NIR: 0.9% yr(-1)), whereas the degradation of HJ-1B CCD1 was most pronounced (blue: 3.5%; green: 4.1%; red: 2.3%; and NIR: 3.4% yr(-1)). The uncertainties of the method were evaluated theoretically based on the propagation of uncertainties from all possible sources of the RT simulations. In addition, a cross comparison with matchup ground-based absolute calibration results was conducted. The comparison demonstrated that the method was useful for continuously monitoring the radiometric performance of remote sensors, such as HJ1A/ 1B CCD and GaoFen (GF) series (China's latest high-definition Earth observation satellite), and indicated the potential use of the method for high-precision absolute calibration. (C) 2015 Optical Society of America
引用
收藏
页码:1829 / 1847
页数:19
相关论文
共 2 条
  • [1] VALIDATION FOR THE ABSOLUTE RADIOMETRIC CALIBRATION OF THE HJ-1B CCD SENSORS OF CHINA
    Jiang, Hongbo
    Qin, Qiming
    Li, Jun
    Zhao, Shaohua
    Dong, Heng
    Yuan, Weilin
    Cui, Rongbo
    2010 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, 2010, : 2876 - 2879
  • [2] Radioactive Quality Evaluation and Cross Validation of Data from the HJ-1A/B Satellites' CCD Sensors
    Zhang, Xin
    Zhao, Xiang
    Liu, Guodong
    Kang, Qian
    Wu, Donghai
    SENSORS, 2013, 13 (07) : 8564 - 8576