The Development of an Instrument to Measure Quality of Vision: The Quality of Vision (QoV) Questionnaire

被引:294
作者
McAlinden, Colm [1 ,2 ]
Pesudovs, Konrad [4 ,5 ]
Moore, Jonathan E. [2 ,3 ]
机构
[1] Univ Ulster, Sch Biomed Sci, Coleraine BT52 1SA, Londonderry, North Ireland
[2] Univ Ulster, Cathedral Eye Clin, Belfast, Antrim, North Ireland
[3] Mater Hosp, Belfast Hlth & Social Care Trust, Belfast, Antrim, North Ireland
[4] Flinders Univ S Australia, Bedford Pk, SA, Australia
[5] Flinders Med Ctr, Dept Optometry & Vis Sci, Ctr Clin Eye Res, NH&MRC Natl Hlth & Med Res Council, Bedford Pk, SA, Australia
关键词
CATARACT-SURGERY OUTCOMES; LASER PHOTOREFRACTIVE KERATECTOMY; RASCH ANALYSIS; PSYCHOMETRIC PROPERTIES; REFRACTIVE ERROR; CONTACT-LENSES; NIGHT-VISION; HIGH MYOPIA; VALIDITY; SCALE;
D O I
10.1167/iovs.10-5341
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To develop an instrument to measure subjective quality of vision: the Quality of Vision (QoV) questionnaire. METHODS. A 30-item instrument was designed with 10 symptoms rated in each of three scales (frequency, severity, and bothersome). The QoV was completed by 900 subjects in groups of spectacle wearers, contact lens wearers, and those having had laser refractive surgery, intraocular refractive surgery, or eye disease and investigated with Rasch analysis and traditional statistics. Validity and reliability were assessed by Rasch fit statistics, principal components analysis (PCA), person separation, differential item functioning (DIF), item targeting, construct validity (correlation with visual acuity, contrast sensitivity, total root mean square [RMS] higher order aberrations [HOA]), and test-retest reliability (two-way random intra-class correlation coefficients [ICC] and 95% repeatability coefficients [R-c]). RESULTS. Rasch analysis demonstrated good precision, reliability, and internal consistency for all three scales (mean square infit and outfit within 0.81-1.27; PCA >60% variance explained by the principal component; person separation 2.08, 2.10, and 2.01 respectively; and minimal DIF). Construct validity was indicated by strong correlations with visual acuity, contrast sensitivity and RMS HOA. Test-retest reliability was evidenced by a minimum ICC of 0.867 and a minimum 95% R-c of 1.55 units. CONCLUSIONS. The QoV Questionnaire consists of a Rasch-tested, linear-scaled, 30-item instrument on three scales providing a QoV score in terms of symptom frequency, severity, and bothersome. It is suitable for measuring QoV in patients with all types of refractive correction, eye surgery, and eye disease that cause QoV problems. (Invest Ophthalmol Vis Sci. 2010;51:5537-5545) DOI: 10.1167/iovs.10-5341
引用
收藏
页码:5537 / 5545
页数:9
相关论文
共 55 条
[1]   Crystalline lens optical dysfunction through aging [J].
Alió, JL ;
Schimchak, P ;
Negri, HP ;
Montés-Micó, R .
OPHTHALMOLOGY, 2005, 112 (11) :2022-2029
[2]   RATING FORMULATION FOR ORDERED RESPONSE CATEGORIES [J].
ANDRICH, D .
PSYCHOMETRIKA, 1978, 43 (04) :561-573
[3]  
[Anonymous], 1993, DIFFERENTIAL ITEM FU
[4]   A NOTE ON THE USE OF THE INTRACLASS CORRELATION-COEFFICIENT IN THE EVALUATION OF AGREEMENT BETWEEN 2 METHODS OF MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
COMPUTERS IN BIOLOGY AND MEDICINE, 1990, 20 (05) :337-340
[5]  
Bond T, 2021, Applying the Rasch Model: Fundamental Measurement in the Human Sciences, V4th
[6]  
British Standards Institution, 1979, Precision of Test Methods I. Guide for the Determination and Reproducibility for a Standard Test Method
[7]   Functional outcome and satisfaction after photorefractive keratectomy - Part 1: Development and validation of a survey questionnaire [J].
Brunette, I ;
Gresset, J ;
Boivin, JF ;
Boisjoly, H ;
Makni, H .
OPHTHALMOLOGY, 2000, 107 (09) :1783-1789
[8]   Functional outcome and satisfaction after photorefractive keratectomy - Part 2: Survey of 690 patients [J].
Brunette, I ;
Gresset, J ;
Boivin, JF ;
Pop, M ;
Thompson, P ;
Lafond, GP ;
Makni, H .
OPHTHALMOLOGY, 2000, 107 (09) :1790-1796
[9]  
Fisher W P Jr, 1997, J Outcome Meas, V1, P329
[10]  
Fraenkel G, 2004, J REFRACT SURG, V20, P10