Direct analysis of bromine and iodine in dried serum spots by laser ablation inductively coupled plasma mass spectrometry

被引:3
作者
He, Jing [1 ]
Li, A-Fang [2 ]
Han, Hua-yun [1 ]
Su, Shuang [1 ]
Zhang, Pei [1 ]
Zhang, Er-peng [3 ]
机构
[1] Zhengzhou Univ, Coll Chem & Mol Engn, Zhengzhou 450000, Peoples R China
[2] Zhengzhou Univ, Affiliated Hosp 1, Zhengzhou, Peoples R China
[3] Henan Prov Ctr Dis Control & Prevent, Zhengzhou 450050, Peoples R China
基金
中国国家自然科学基金;
关键词
LA-ICP-MS; WHOLE-BLOOD; DIGESTION; SCIENCES; SAMPLES;
D O I
10.1002/rcm.8591
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale Accurate quantitative analysis of bromine and iodine in serum is an important aspect of monitoring body condition, but the volatile loss of halogen in sample pretreatment is a troublesome problem. We present a validated and flexible high-throughput method for quantification of bromine and iodine in dried serum spots (DSS) using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and an external aqueous standard calibration curve. The influence of serum matrix and laser ablation (LA) conditions on the analysis of bromine and iodine in DSS was researched systematically. Methods Aqueous standards without matrix matching were used for calibration to analyze bromine and iodine in serum by LA-ICP-MS. 5-mu L volumes of the aqueous standard solution and serum samples in 10 times diluted concentration were deposited on the PTFE paper to form dried standard calibration spots (DSCS) and DSS, of less than 2 mm in diameter. LA was performed using a focused Nd:YAG laser beam in raster lineal scan mode. Results The limits of detection (LODs) for bromine and iodine in DSS were 0.23 and 0.03 mg L-1, respectively. The relative standard deviation (RSD) for this method was less than 10%. The samples were also detected with matrix matching calibration by ICP-MS. The accuracy of the method was verified by statistical analysis of these results from ICP-MS and LA-ICP-MS. The accuracy is satisfactory with recoveries ranging from 81.5% to 118%. Conclusions A novel and simple approach for high-throughput screening of bromine and iodine in DSS has been established by LA-ICP-MS. Calibration could be achieved using an aqueous standard solution instead of a matrix-matching solution. The method allowed analysis of low-volume biological samples without derivatization and decreased the risk of contamination or loss.
引用
收藏
页数:9
相关论文
共 36 条
  • [31] OPTIMUM DOSES OF DEUTERIUM-OXIDE AND SODIUM-BROMIDE FOR THE DETERMINATION OF TOTAL-BODY WATER AND EXTRACELLULAR FLUID
    THOMAS, LD
    VANDERVELDE, D
    SCHLOERB, PR
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1991, 9 (07) : 581 - 584
  • [32] EFFECT OF SOLVENT TYPE ON THE DETERMINATION OF TOTAL IODINE IN MILK POWDER AND HUMAN SERUM BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY
    VANHOE, H
    VANALLEMEERSCH, F
    VERSIECK, J
    DAMS, R
    [J]. ANALYST, 1993, 118 (08) : 1015 - 1019
  • [33] Weir EG, 1939, J BIOL CHEM, V129, P547
  • [34] Zakaria Rosita, 2016, EJIFCC, V27, P288
  • [35] Elemental fractionation and matrix effects in laser sampling based spectrometry
    Zhang, Shudi
    He, Miaohong
    Yin, Zhibin
    Zhu, Eryi
    Hang, Wei
    Huang, Benli
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (02) : 358 - 382
  • [36] Perchlorate and Iodide in Whole Blood Samples from Infants, Children, and Adults in Nanchang, China
    Zhang, Tao
    Wu, Qian
    Sun, Hong Wen
    Rao, Jia
    Kannan, Kurunthachalam
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (18) : 6947 - 6953