Direct analysis of bromine and iodine in dried serum spots by laser ablation inductively coupled plasma mass spectrometry

被引:3
作者
He, Jing [1 ]
Li, A-Fang [2 ]
Han, Hua-yun [1 ]
Su, Shuang [1 ]
Zhang, Pei [1 ]
Zhang, Er-peng [3 ]
机构
[1] Zhengzhou Univ, Coll Chem & Mol Engn, Zhengzhou 450000, Peoples R China
[2] Zhengzhou Univ, Affiliated Hosp 1, Zhengzhou, Peoples R China
[3] Henan Prov Ctr Dis Control & Prevent, Zhengzhou 450050, Peoples R China
基金
中国国家自然科学基金;
关键词
LA-ICP-MS; WHOLE-BLOOD; DIGESTION; SCIENCES; SAMPLES;
D O I
10.1002/rcm.8591
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale Accurate quantitative analysis of bromine and iodine in serum is an important aspect of monitoring body condition, but the volatile loss of halogen in sample pretreatment is a troublesome problem. We present a validated and flexible high-throughput method for quantification of bromine and iodine in dried serum spots (DSS) using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and an external aqueous standard calibration curve. The influence of serum matrix and laser ablation (LA) conditions on the analysis of bromine and iodine in DSS was researched systematically. Methods Aqueous standards without matrix matching were used for calibration to analyze bromine and iodine in serum by LA-ICP-MS. 5-mu L volumes of the aqueous standard solution and serum samples in 10 times diluted concentration were deposited on the PTFE paper to form dried standard calibration spots (DSCS) and DSS, of less than 2 mm in diameter. LA was performed using a focused Nd:YAG laser beam in raster lineal scan mode. Results The limits of detection (LODs) for bromine and iodine in DSS were 0.23 and 0.03 mg L-1, respectively. The relative standard deviation (RSD) for this method was less than 10%. The samples were also detected with matrix matching calibration by ICP-MS. The accuracy of the method was verified by statistical analysis of these results from ICP-MS and LA-ICP-MS. The accuracy is satisfactory with recoveries ranging from 81.5% to 118%. Conclusions A novel and simple approach for high-throughput screening of bromine and iodine in DSS has been established by LA-ICP-MS. Calibration could be achieved using an aqueous standard solution instead of a matrix-matching solution. The method allowed analysis of low-volume biological samples without derivatization and decreased the risk of contamination or loss.
引用
收藏
页数:9
相关论文
共 36 条
  • [1] DETERMINATION OF IODINE AND BROMINE IN PLASMA AND URINE BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
    ALLAIN, P
    MAURAS, Y
    DOUGE, C
    JAUNAULT, L
    DELAPORTE, T
    BEAUGRAND, C
    [J]. ANALYST, 1990, 115 (06) : 813 - 815
  • [2] Determination of total iodine in serum and urine samples by ion chromatography with pulsed amperometric detection - Studies on analyte loss, optimization of sample preparation procedures, and validation of analytical method
    Blazewicz, Anna
    Klatka, Maria
    Dolliver, Wojciech
    Kocjan, Ryszard
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 962 : 141 - 146
  • [3] Perinatal Exposure to Perchlorate, Thiocyanate, and Nitrate in New Jersey Mothers and Newborns
    Blount, Benjamin C.
    Rich, David Q.
    Valentin-Blasini, Liza
    Lashley, Susan
    Ananth, Cande V.
    Murphy, Eileen
    Smulian, John C.
    Spain, Betty J.
    Barr, Dana B.
    Ledoux, Thomas
    Hore, Paromita
    Robson, Mark
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (19) : 7543 - 7549
  • [4] Brodie BB, 1939, J BIOL CHEM, V130, P555
  • [5] Cao LY, 2012, J MED POSTGRAD, V11, P1151
  • [6] Evaluation of bromine and iodine content of milk whey proteins combining digestion by microwave-induced combustion and ICP-MS determination
    da Silva, Sabrina Vieira
    Picoloto, Rochele Sogari
    Moraes Flores, Erico Marlon
    Wagner, Roger
    Pereira dos Santos Richards, Neila Silvia
    Barin, Juliano Smanioto
    [J]. FOOD CHEMISTRY, 2016, 190 : 364 - 367
  • [7] Biomonitoring of essential and toxic metals in single hair using on-line solution-based calibration in laser ablation inductively coupled plasma mass spectrometry
    Dressler, Valderi L.
    Pozebon, Dirce
    Mesko, Marcia Foster
    Matusch, Andreas
    Kumtabtim, Usarat
    Wu, B.
    Becker, J. Sabine
    [J]. TALANTA, 2010, 82 (05) : 1770 - 1777
  • [8] Fielding CL, 2003, J VET INTERN MED, V17, P213, DOI 10.1892/0891-6640(2003)017<0213:PACUOS>2.3.CO
  • [9] 2
  • [10] Guthrie KJR, 1997, PKU STORY CRUSADE ME