Relation between the particle size distribution and the kinetic performance of packed columns -: Application to a commercial sub-2 μm particle material

被引:50
作者
Billen, Jeroen
Guillarme, Davy
Rudaz, Serge
Veuthey, Jean-Luc
Ritchie, Harald
Grady, Brian
Desmet, Gert
机构
[1] Vrije Univ Brussel VIB, Dept Chem Engn, B-1050 Brussels, Belgium
[2] Univ Lausanne, Univ Geneva, Sch Pharmaceut Sci, Lab Analyt Pharmaceut Chem, CH-1211 Geneva, Switzerland
[3] Thermo Fisher Sci, Runcorn, Cheshire, England
关键词
particle size distribution; UPLC; kinetic plot;
D O I
10.1016/j.chroma.2007.05.088
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To study the influence of the particle size distribution (PSD), we measured the chromatographic performance of a series of sub-2 mu m particle high performance liquid chromatography (HPLC) columns packed with four different particle mixtures having a purposely imposed different size distribution. Using the reduced kinetic plot representation by plotting the separation impedance (E-0) versus the plate number ratio (N-opt/N), the different columns could be classified according to their chromatographic performance without the need to specify a mean particle diameter or a molecular diffusion coefficient, as is needed in the classical reduced plate height and flow resistance analysis. The present analysis shows that it is not so much the width or span of the particle size distribution, but rather the presence of fines that greatly determines the chromatographic performance of particulate columns. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:224 / 233
页数:10
相关论文
共 22 条
[1]   PREDICTABILITY OF CHROMATOGRAPHIC PROTEIN SEPARATIONS - STUDY OF SIZE-EXCLUSION MEDIA WITH NARROW PARTICLE-SIZE DISTRIBUTIONS [J].
ATHALYE, AM ;
GIBBS, SJ ;
LIGHTFOOT, EN .
JOURNAL OF CHROMATOGRAPHY, 1992, 589 (1-2) :71-85
[2]  
BARBER W, 2005, 29 INT S HIGH PERF L
[3]   Use of the kinetic plot method to analyze commercial high-temperature liquid chromatography systems I: Intrinsic performance comparison [J].
Cabooter, D. ;
Heinisch, S. ;
Rocca, J. L. ;
Clicq, D. ;
Desmet, G. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1143 (1-2) :121-133
[4]   Geometry-independent plate height representation methods for the direct comparison of the kinetic performance of LC supports with a different size or morphology [J].
Desmet, G ;
Clicq, D ;
Gzil, P .
ANALYTICAL CHEMISTRY, 2005, 77 (13) :4058-4070
[5]   Future of high pressure liquid chromatography: Do we need porosity or do we need pressure? [J].
Desmet, Gert ;
Cabooter, Deirdre ;
Gzil, Piotr ;
Verelst, Harry ;
Mangelings, Debby ;
Vander Heyden, Yvan ;
Clicq, David .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1130 (01) :158-166
[6]   INFLUENCE OF THE PARTICLE-SIZE DISTRIBUTION OF THE PACKING MATERIAL IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
DEWAELE, C ;
VERZELE, M .
JOURNAL OF CHROMATOGRAPHY, 1983, 260 (01) :13-21
[7]   INFLUENCE OF PARTICLE-SIZE (5-35MUM) OF SPHERICAL SILICA ON COLUMN EFFICIENCIES IN HIGH-PRESSURE LIQUID-CHROMATOGRAPHY [J].
ENDELE, R ;
HALASZ, I ;
UNGER, K .
JOURNAL OF CHROMATOGRAPHY, 1974, 99 (NOV6) :377-393
[8]  
GOLAY M, 1958, GAS CHROMATOGRAPHY, P195
[9]   Effect of temperature in reversed phase liquid chromatography [J].
Guillarme, D ;
Heinisch, S ;
Rocca, JL .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1052 (1-2) :39-51
[10]   ULTIMATE LIMITS IN HIGH-PRESSURE LIQUID-CHROMATOGRAPHY [J].
HALASZ, I ;
ENDELE, R ;
ASSHAUER, J .
JOURNAL OF CHROMATOGRAPHY, 1975, 112 (OCT29) :37-60