Comparison of the effective dose rate to aircrew members using hybrid computational phantoms in standing and sitting postures

被引:3
作者
Alves, M. C. [1 ]
Galeano, D. C. [1 ,7 ]
Santos, W. S. [2 ]
Lee, Choonsik [3 ]
Bolch, Wesley E. [4 ]
Hunt, John G. [5 ,6 ]
da Silva, A. X.
Carvalho, A. B., Jr. [1 ]
机构
[1] Univ Fed Sergipe, Dept Fis, Campus Prof Jose Aloisio de Campos, BR-100000 Sao Cristovao, SE, Brazil
[2] Univ Fed Uberlandia, Inst Fis, INFIS UFU, Caixa Postal 593, BR-38400902 Uberlandia, MG, Brazil
[3] NCI, Div Canc Epidemiol & Genet, NIH, Rockville, MD 20852 USA
[4] Univ Florida, Dept Nucl & Radiol Engn, Gainesville, FL 32611 USA
[5] Inst Radioprotecao & Dosimetria, Dosimetry Div, BR-22783127 Rio De Janeiro, RJ, Brazil
[6] Univ Fed Rio de Janeiro, Dept Nucl Engn, Escola Politecn, BR-21941972 Rio De Janeiro, Brazil
[7] Univ Fed Rondonia, Dept Fis, Porto Velho, RO, Brazil
关键词
aircrew dosimetry; effective dose conversion coefficients; Monte Carlo simulation; effective dose rate; sitting phantom; COSMIC-RADIATION EXPOSURE; CONVERSION COEFFICIENTS; CREW; NURBS; ORGAN;
D O I
10.1088/0952-4746/36/4/885
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Aircraft crew members are occupationally exposed to considerable levels of cosmic radiation at flight altitudes. Since aircrew (pilots and passengers) are in the sitting posture for most of the time during flight, and up to now there has been no data on the effective dose rate calculated for aircrew dosimetry in flight altitude using a sitting phantom, we therefore calculated the effective dose rate using a phantom in the sitting and standing postures in order to compare the influence of the posture on the radiation protection of aircrew members. We found that although the better description of the posture in which the aircrews are exposed, the results of the effective dose rate calculated with the phantom in the sitting posture were very similar to the results of the phantom in the standing posture. In fact we observed only a 1% difference. These findings indicate the adequacy of the use of dose conversion coefficients for the phantom in the standing posture in aircrew dosimetry. We also validated our results comparing the effective dose rate obtained using the standing phantom with values reported in the literature. It was observed that the results presented in this study are in good agreement with other authors (the differences are below 30%) who have measured and calculated effective dose rates using different phantoms.
引用
收藏
页码:885 / 901
页数:17
相关论文
共 29 条
[1]   Organ and effective dose conversion coefficients for a sitting female hybrid computational phantom exposed to monoenergetic protons in idealized irradiation geometries [J].
Alves, M. C. ;
Santos, W. S. ;
Lee, Choonsik ;
Bolch, Wesley E. ;
Hunt, John G. ;
Carvalho Junior, A. B. .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (24) :7957-8003
[2]   Radiation protection aspects of the cosmic radiation exposure of aircraft crew [J].
Bartlett, DT .
RADIATION PROTECTION DOSIMETRY, 2004, 109 (04) :349-355
[3]   Comparison of conversion coefficients for equivalent dose in terms of air kerma using a sitting and standing female adult voxel simulators exposure to photons in antero-posterior irradiation geometry [J].
Cavalcante, F. R. ;
Galeano, D. C. ;
Carvalho Junior, A. B. ;
Hunt, J. .
RADIATION PHYSICS AND CHEMISTRY, 2014, 95 :158-160
[4]  
European Commission, 2004, Cosmic radiation exposure of aircraft crew: compilation of measured and calculated data
[5]   Calculation of the radiation environment caused by galactic cosmic rays for determining air crew exposure [J].
Ferrari, A ;
Pelliccioni, M ;
Rancati, T .
RADIATION PROTECTION DOSIMETRY, 2001, 93 (02) :101-114
[6]   A methodology to develop computational phantoms with adjustable posture for WBC calibration [J].
Fonseca, T. C. Ferreira ;
Bogaerts, R. ;
Hunt, John ;
Vanhavere, F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (22) :6811-6825
[7]   Fluence-to-dose conversion coefficients based on the posture modification of Adult Male (AM) and Adult Female (AF) reference phantoms of ICRP 110 [J].
Galeano, D. C. ;
Santos, W. S. ;
Alves, M. C. ;
Souza, D. N. ;
Carvalho, A. B., Jr. .
RADIATION PHYSICS AND CHEMISTRY, 2016, 121 :50-60
[8]   The energy spectrum of cosmic-ray induced neutrons measured on an airplane over a wide range of altitude and latitude [J].
Goldhagen, P ;
Clem, JM ;
Wilson, JW .
RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) :387-392
[9]   Effective dose conversion coefficients for health care provider exposed to pediatric and adult victims in radiological dispersal device incident [J].
Han, Eun Young ;
Ha, Wi-Ho ;
Jin, Young-Woo ;
Bolch, Wesley E. ;
Lee, Choonsik .
JOURNAL OF RADIOLOGICAL PROTECTION, 2015, 35 (01) :37-45
[10]   Physics of cosmic radiation fields [J].
Heinrich, W ;
Roesler, S ;
Schraube, H .
RADIATION PROTECTION DOSIMETRY, 1999, 86 (04) :253-258