An attempt is made to determine why one cannot rely on an absolute partial discharge (PD) magnitude to assess the insulation condition of rotating machines. Case studies are considered to show how to identify stator insulation deterioration effectively and reliably. Finally, it is illustrated that trending of PD activity is the reliable way to identify severe insulation deterioration in rotating machines.
引用
收藏
页码:21 / 26
页数:6
相关论文
共 11 条
[1]  
HOLBOLL JT, 1996, IEEE INT S EL INS MO, P192
[2]  
*IEEE, P1434 IEEE
[3]  
JOHNSON JS, 1951, AIEE T, V70, P1993
[4]  
Kemp I. J., 1987, Proceedings of the 18th Electrical Electronics Insulation Conference, Chicago '87 EEIC/ICWA Exposition (IEEE Cat. No. 87CH2452-1), P92
[5]  
KEMP IJ, 1996, IEE P A, V143
[6]  
SEDDING H, 1992, IEEE WINT M 1992
[7]   Partial discharge part XXV: Calibration of PD measurements for motor and generator windings - Why it can't be done [J].
Stone, GC .
IEEE ELECTRICAL INSULATION MAGAZINE, 1998, 14 (01) :9-12
[8]   PARTIAL DISCHARGES IN HV MACHINES - INITIAL CONSIDERATIONS FOR A PD SPECIFICATION [J].
WOOD, JW ;
SEDDING, HG ;
HOGG, WK ;
KEMP, IJ ;
ZHU, H .
IEE PROCEEDINGS-A-SCIENCE MEASUREMENT AND TECHNOLOGY, 1993, 140 (05) :409-416
[9]  
Zhu H, 1999, IEEE T ENERGY CONVER, V14, P1184, DOI 10.1109/60.815045
[10]  
ZHU H, 1997, 10 INT S HIGH VOLT E