Cross-talk-free multiplexed immunoassay using a disposable electrochemiluminescent immunosensor array coupled with a non-array detector

被引:38
作者
Li, Cuifang [1 ]
Fu, Zhifeng [1 ]
Li, Zongyun [1 ]
Wang, Zhenxing [1 ]
Wei, Wei [1 ]
机构
[1] Southwest Univ, Coll Pharmaceut Sci, Minist Educ, Key Lab Luminescence & Real Time Anal, Chongqing 400716, Peoples R China
基金
高等学校博士学科点专项科研基金;
关键词
Multiplexed immunoassay; Electrochemiluminescence; Immunosensor array; Screen-printed carbon electrode; Immunoglobulin; MULTIANALYTE; ASSAY; NANOPARTICLES; MICROARRAY; ANTIBODIES; PROTEINS;
D O I
10.1016/j.bios.2011.06.031
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A disposable electrochemiluminescent (ECL) immunosensor array was fabricated on a screen-printed carbon electrode (SPCE) substrate to perform multiplexed immunoassay (MIA) for the first time. The SPCE substrate was composed of an array of four carbon working electrodes, one common Ag/AgCl reference electrode, and one common carbon counter electrode. The immunosensor array was constructed by site-selectively immobilizing multiple antigens on different working electrodes of the SPCE substrate. With a competitive immunoassay format, the immobilized antigens competed with antigens in the sample to capture their corresponding tri(2,2'-bipyridyl)ruthenium(11)-labeled antibodies. The ECL signals from the immunosensors in this array were sequentially detected by a photomultiplier with the aid of a homemade single-pore-four-throw switch. Due to the ECL readout mechanism and the sequential detection mode, it could avoid the cross-talk between the adjacent immunosensors, which was common in other reported immunosensor array. Human, rabbit and mouse immunoglobulin Gs were near-simultaneously assayed as the model analytes. The linear ranges for them were 10-400,20-400, and 20-400 ng/mL, with detection limits of 2.9, 6.1 and 6.5 ng/mL (S/N = 3), respectively. This novel ECL strategy based on immunosensor array coupled with non-array detector provided a simple, sensitive, low-cost and time-saving approach for MIA. It showed great application potential in point-of-care test and field analysis of bio-agents, with mass production potential and high throughput. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:141 / 147
页数:7
相关论文
共 41 条
[1]   Double-codified gold nanolabels for enhanced immunoanalysis [J].
Ambrosi, Adriano ;
Castaneda, Maria Teresa ;
Killard, Anthony J. ;
Smyth, Malcolm R. ;
Alegret, Salvador ;
Merkoci, Arben .
ANALYTICAL CHEMISTRY, 2007, 79 (14) :5232-5240
[2]   Development of dual-enzyme-based simultaneous immunoassay for measurement of progesterone and human chorionic gonadotropin [J].
Basu, Anupam ;
Maitra, Saumen Kumar ;
Shrivastav, Tulsidas G. .
ANALYTICAL BIOCHEMISTRY, 2007, 366 (02) :175-181
[3]   Single-Wall Carbon Nanotube Forest Arrays for Immunoelectrochemical Measurement of Four Protein Biomarkers for Prostate Cancer [J].
Chikkaveeraiah, Bhaskara V. ;
Bhirde, Ashwin ;
Malhotra, Ruchika ;
Patel, Vyomesh ;
Gutkind, J. Silvio ;
Rusling, James F. .
ANALYTICAL CHEMISTRY, 2009, 81 (21) :9129-9134
[4]  
de la Escosura-Muniz Alfredo, 2010, Materials Today, V13, P24, DOI 10.1016/S1369-7021(10)70125-5
[5]   Multiplexed Sandwich Immunoassays Using Electrochemiluminescence Imaging Resolved at the Single Bead Level [J].
Deiss, Frederique ;
LaFratta, Christopher N. ;
Symer, Matthew ;
Blicharz, Timothy M. ;
Sojic, Neso ;
Walt, David R. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2009, 131 (17) :6088-+
[6]  
Ding J. F., 2004, GENE ANAL BIOCHIP TE
[7]   A channel-resolved approach coupled with magnet-captured technique for multianalyte chemiluminescent immunoassay [J].
Fu, Zhifeng ;
Yan, Feng ;
Liu, Hong ;
Lin, Jiehua ;
Ju, Huangxian .
BIOSENSORS & BIOELECTRONICS, 2008, 23 (10) :1422-1428
[8]   Flow-through multianalyte chemiluminescent immunosensing system with designed substrate zone-resolved technique for sequential detection of tumor markers [J].
Fu, Zhifeng ;
Liu, Hong ;
Ju, Huangxian .
ANALYTICAL CHEMISTRY, 2006, 78 (19) :6999-7005
[9]   Multiplexed toxin analysis using four colors of quantum dot fluororeagents [J].
Goldman, ER ;
Clapp, AR ;
Anderson, GP ;
Uyeda, HT ;
Mauro, JM ;
Medintz, IL ;
Mattoussi, H .
ANALYTICAL CHEMISTRY, 2004, 76 (03) :684-688
[10]  
GOW SM, 1986, CLIN CHEM, V32, P2191