A new heat and moisture exchanger with speech valve (Provox(R) stomafilter)

被引:33
作者
Hilgers, FJM
Ackerstaff, AH
Balm, AJM
Gregor, RT
机构
[1] ANTONI VAN LEEUWENHOEK HOSP,NETHERLANDS CANC INST,DEPT PSYCHOSOCIAL RES,NL-1066 CX AMSTERDAM,NETHERLANDS
[2] ANTONI VAN LEEUWENHOEK HOSP,NETHERLANDS CANC INST,DEPT EPIDEMIOL,NL-1066 CX AMSTERDAM,NETHERLANDS
来源
CLINICAL OTOLARYNGOLOGY | 1996年 / 21卷 / 05期
关键词
pulmonary rehabilitation; total laryngectomy;
D O I
10.1046/j.1365-2273.1996.00817.x
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
In previous studies investigating the influence of a heat and moisture exchanger on the respiratory and psychosocial problems of laryngectomized patients, the value of regular use of such a device could clearly be established. However, the compliance with the use of these devices was not optimal, mainly due to problems related to the plaster and to the often troublesome combination of these HMEs with a voice prosthesis. Therefore, a prospective, clinical trial was undertaken to investigate whether the use of a newly developed heat and moisture exchanger (HME, Provox(R) stomafilter) could improve the acceptibility of such a device. In total, 19 patients participated in this study, 13 men and six women. Vocal rehabilitation was achieved with a Provox(R) voice prosthesis in all patients. Each of the patients was provided with a supply of HMEs for a 3-week trial period. The results showed that all patients were clearly positive about the valve used for digital occlusion of the stoma. Voicing was considerably facilitated and the intelligibility improved. Problems experienced in previous studies related to the adhesive tape, such as skin irritation, inadequate adherence and loosening of the plaster by coughing or forced expectoration, could be solved by the availability of the different adhesives included in this system.
引用
收藏
页码:414 / 418
页数:5
相关论文
共 17 条
[1]   IMPROVEMENTS IN RESPIRATORY AND PSYCHOSOCIAL FUNCTIONING FOLLOWING TOTAL LARYNGECTOMY BY THE USE OF A HEAT AND MOISTURE EXCHANGER [J].
ACKERSTAFF, AH ;
HILGERS, FJM ;
AARONSON, NK ;
BALM, AJM ;
VANZANDWIJK, N .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1993, 102 (11) :878-883
[2]   Heat and moisture exchangers as a treatment option in the post-operative rehabilitation of laryngectomized patients [J].
Ackerstaff, AH ;
Hilgers, FJM ;
Aaronson, NK ;
DeBoer, MF ;
Meeuwis, CA ;
Knegt, PPM ;
Spoelstra, HAA ;
VanZandwijk, N ;
Balm, AJM .
CLINICAL OTOLARYNGOLOGY, 1995, 20 (06) :504-509
[3]   Long-term pulmonary function after total laryngectomy [J].
Ackerstaff, AH ;
Hilgers, FJM ;
Balm, AJM ;
VanZandwijk, N .
CLINICAL OTOLARYNGOLOGY, 1995, 20 (06) :547-551
[4]   COMMUNICATION, FUNCTIONAL-DISORDERS AND LIFE-STYLE CHANGES AFTER TOTAL LARYNGECTOMY [J].
ACKERSTAFF, AH ;
HILGERS, FJM ;
AARONSON, NK ;
BALM, AJM .
CLINICAL OTOLARYNGOLOGY, 1994, 19 (04) :295-300
[5]   AN ENDOSTOMAL TRACHEOSTOMY TUBE FOR LEAKPROOF RETENTION OF THE BLOM-SINGER STOMAL VALVE [J].
BARTON, D ;
DESANTO, L ;
PEARSON, BW ;
KEITH, R .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1988, 99 (01) :38-41
[6]   TRACHEOSTOMA VALVE FOR POSTLARYNGECTOMY VOICE REHABILITATION [J].
BLOM, ED ;
SINGER, MI ;
HAMAKER, RC .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1982, 91 (06) :576-578
[7]  
CANTU E, 1986, LARYNGOSCOPE, V96, P1159
[8]   CLINICAL MODIFICATION OF THE TRACHEOSTOMA BREATHING VALVE FOR VOICE RESTORATION [J].
DOYLE, PC ;
GRANTMYRE, A ;
MYERS, C .
JOURNAL OF SPEECH AND HEARING DISORDERS, 1989, 54 (02) :189-192
[9]  
GERWIN JM, 1993, AM J OTOLARYNG, V6, P432
[10]   LUNG-FUNCTION BEFORE AND AFTER LARYNGECTOMY [J].
HARRIS, S ;
JONSON, B .
ACTA OTO-LARYNGOLOGICA, 1974, 78 (3-4) :287-294