Interaction between local corrosion and flow field of natural gas long-distance pipeline by artificial rectangular defect pit

被引:8
作者
Tan, Zhuo-wei [1 ,2 ]
Wang, Zhen-bo [1 ]
Bai, Shu-yu [3 ]
Zhang, Da-lei [3 ]
Zhang, Sheng-zhu [4 ]
Cheng, Frank [5 ]
Xing, Shao-hua [6 ]
Jin, You-hai [1 ]
机构
[1] China Univ Petr East China, Qingdao 266580, Shandong, Peoples R China
[2] Xiangtan Univ, Xiangtan 411105, Hunan, Peoples R China
[3] China Univ Petr East China, Sch Mat Sci & Engn, Qingdao 266580, Shandong, Peoples R China
[4] China Acad Safety Sci & Technol, Beijing 100012, Peoples R China
[5] Univ Calgary, Calgary, AB T2N 1N4, Canada
[6] Luoyang Ship Mat Res Inst, State Key Marine Corros & Protect, Qingdao 266237, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
CO2; corrosion; Flow condition; Rectangular defect pit; Local corrosion; Corrosion electrochemistry; ACCELERATED CORROSION; CO2; CORROSION; EROSION-CORROSION; CARBON-STEEL; MASS-TRANSFER; TURBULENT-FLOW; MILD-STEEL; X65; STEEL; ELECTROCHEMICAL CORROSION; DIFFERENT LOCATIONS;
D O I
10.1007/s42243-022-00754-y
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
The corrosive environment in long-distance natural gas pipeline was simulated by the online high shear stress flow test platform. The interaction between flow fields and local corrosion in different local corrosion stages was studied by machining different depths rectangular defect pit (RDP) on X80 pipe steel specimens. The electrochemical signals of each specimen under high shear stress flow were measured online using an integrated three-electrode and electrochemical system. Raman spectroscopy confirmed that the corrosion scale of X80 pipeline steel in CO2-saturated National Association of Corrosion Engineers solution was composed of FeCO3. The scanning electron microscope images displayed variations in microstructure of the corrosion scale at different RDP depths and different areas. The flow field fluctuations induced by RDP were analyzed by computational fluid dynamics simulations and the development of local corrosion pits was discussed in terms of integrity of corrosion scale, convective mass transfer, and diffusion mass transfer.
引用
收藏
页码:1026 / 1038
页数:13
相关论文
共 51 条
  • [1] Flow and mass transfer downstream of an orifice under flow accelerated corrosion conditions
    Ahmed, Wael H.
    Bello, Mufatiu M.
    El Nakla, Meamer
    Al Sarkhi, Abdelsalam
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2012, 252 : 52 - 67
  • [2] Efficiency of film-forming corrosion inhibitors in strong hydrochloric acid under laminar and turbulent flow conditions
    Barmatov, Evgeny
    Hughes, Trevor
    Nagl, Michaela
    [J]. CORROSION SCIENCE, 2015, 92 : 85 - 94
  • [3] Buzgar N., 2009, GEOLOGIE, V55, P97
  • [4] Cooney TF, 1999, AM MINERAL, V84, P1569
  • [5] Study of molten salt corrosion of HK-40m alloy applying linear polarization resistance and conventional weight loss techniques
    Cuevas-Arteaga, C
    Uruchurtu-Chavarín, J
    Porcayo-Calderon, J
    Izquierdo-Montalvo, G
    Gonzalez, J
    [J]. CORROSION SCIENCE, 2004, 46 (11) : 2663 - 2679
  • [6] Dugstad A., 1998, NACE98031 NACE INT, V98
  • [7] CO2 corrosion control in steel pipelines. Influence of turbulent flow on the performance of corrosion inhibitors
    Elena Olvera-Martinez, Maria
    Mendoza-Flores, Juan
    Genesca, J.
    [J]. JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2015, 35 : 19 - 28
  • [8] Mechanisms of Corrosion and Electrochemical Significance of Metallurgy and Environment with Corrosion of Iron and Steel in Bicarbonate and Carbonate Solutions-A Review
    Eliyan, Faysal Fayez
    Alfantazi, Akram
    [J]. CORROSION, 2014, 70 (09) : 880 - 898
  • [9] Effect of hydrodynamics and surface roughness on the electrochemical behaviour of carbon steel in CSG produced water
    Eyu, Gaius Debi
    Will, Geoffrey
    Dekkers, Willem
    MacLeod, Jennifer
    [J]. APPLIED SURFACE SCIENCE, 2015, 357 : 506 - 515
  • [10] Influence of environmental parameters on the corrosion behavior of 90/10 cupronickel tubes in 3.5% NaCl
    Ezuber, Hosni M.
    Al Shater, Abdulla