Comparison of nonabsorbable polymer ligating and standard titanium clips with and without a vascular cuff

被引:16
作者
Jellison, FC [1 ]
Baldwin, DD [1 ]
Berger, KA [1 ]
Maynes, LJ [1 ]
Desai, PJ [1 ]
机构
[1] Loma Linda Univ, Med Ctr, Div Urol Surg, Loma Linda, CA 92354 USA
关键词
D O I
10.1089/end.2005.19.889
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To compare the efficacy of nonabsorbable polymer ligating (NPL) and titanium clips applied with and without a 1-mm vascular cuff at physiologic and supraphysiologic pressures. Materials and Methods: An in vitro equine-vessel model was created to test clip occlusion strength. Ten-millimeter NPL and standard Ti clips were applied to veins (10 mm) and arteries (10, 6, and 5 mm) with and without a 1-mm cuff and tested until they held a pressure of 300 mm Hg (veins) or 760 mm Hg (arteries) for 2 minutes or leaked. Results: The NPL clip was statistically more secure on 10-mm veins with and without a cuff, 10-mm arteries with and without a cuff, and 6-mm arteries with a cuff than was the Ti clip. Leaving a 1-mm cuff resulted in a statistically higher leak point in all vessels tested except the 6-mm arteries secured with the Ti clip. Conclusions: The NPL clip was more secure than the Ti clip on larger arteries and veins. A I-mm vascular cuff enhances the security of both NPL and Ti clips in vessels of all sizes. The NPL clip is secure and reliable in securing both arteries and veins.
引用
收藏
页码:889 / 893
页数:5
相关论文
共 22 条
[1]   LAPAROSCOPIC NEPHRECTOMY AND ADRENALECTOMY [J].
ALBALA, DM .
SEMINARS IN SURGICAL ONCOLOGY, 1994, 10 (06) :417-421
[2]   Open conversion from laparoscopic nephrectomy: Slippage of surgical clips ligating the renal artery affected by atherosclerosis [J].
Baek, M ;
Chun, HK ;
Oh, SJ ;
Kim, HH .
JOURNAL OF UROLOGY, 2004, 171 (01) :333-334
[3]   Laparoscopic radical nephrectomy with morcellation for renal cell carcinoma: The Saskatoon experience [J].
Barrett, PH ;
Fentie, DD ;
Taranger, LA .
UROLOGY, 1998, 52 (01) :23-28
[4]  
BRUNT LM, 1993, SURG LAPAROSC ENDOSC, V3, P300
[5]   Endovascular gastrointestinal stapler device malfunction during laparoscopic nephrectomy: Early recognition and management [J].
Chan, D ;
Bishoff, JT ;
Ratner, L ;
Kavoussi, LR ;
Jarrett, TW .
JOURNAL OF UROLOGY, 2000, 164 (02) :319-321
[6]   Rapid ligation of renal hilum during transperitoneal laparoscopic nephrectomy [J].
Chan, DY ;
Su, LM ;
Kavoussi, LR .
UROLOGY, 2001, 57 (02) :360-362
[7]   Novel intracorporeal vascular knot applier for large vessel ligation in laparoscopic surgery: Experience in pigs and preliminary clinical use [J].
Chiu, AW ;
Wu, ST ;
Sun, GH ;
Liu, CJ ;
Lin, JJ ;
Tseng, CY ;
Lin, JT .
JOURNAL OF ENDOUROLOGY, 2003, 17 (02) :73-78
[8]   Laparoscopic linear cutting stapler failure [J].
Deng, DY ;
Meng, MV ;
Nguyen, HT ;
Bellman, GC ;
Stoller, ML .
UROLOGY, 2002, 60 (03) :415-419
[9]   Retroperitoneal laparoscopic radical nephrectomy: The Cleveland Clinic experience [J].
Gill, IS ;
Schweizer, D ;
Hobart, MG ;
Sung, GT ;
Klein, EA ;
Novick, AC .
JOURNAL OF UROLOGY, 2000, 163 (06) :1665-1670
[10]   Renovascular complications of laparoscopic donor nephrectomy [J].
Hsu, THS ;
Su, LM ;
Ratner, LE ;
Kavoussi, LR .
UROLOGY, 2002, 60 (05) :811-815