RF atomic magnetometer array with over 40 dB interference suppression using electron spin resonance

被引:11
作者
Cooper, Robert J. [1 ]
Prescott, David W. [1 ]
Lee, Garrett J. [1 ]
Sauer, Karen L. [1 ]
机构
[1] George Mason Univ, Dept Phys & Astron, Fairfax, VA 22030 USA
基金
美国国家科学基金会;
关键词
Electron spin resonance; Atomic magnetometer array; RF magnetic field mapping; Unshielded detection; Interference rejection; Low-field magnetic resonance; NUCLEAR-QUADRUPOLE RESONANCE; MAGNETOCARDIOGRAPHY MEASUREMENTS; MAGNETOENCEPHALOGRAPHY; FIELD; EXPLOSIVES; MRI;
D O I
10.1016/j.jmr.2018.08.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An unshielded array of Rb-87 atomic magnetometers, operating close to 1 MHz, is used to attenuate interference by 42-48 dB. A sensitivity of 15 fT/root Hz to a local source of signal is retained. In addition, a 2D spectroscopic technique, in which the magnetometers are repeatedly pumped and data acquired between pump times, enables a synchronously generated signal to be distinguished from an interfering signal very close in frequency; the timing and signal mimics what would be observed in a magnetic resonance echo train. Combining the interference rejection and the 2D spectroscopy techniques, a 100 ft local signal is differentiated from a 20 pT interference signal operating only 1 Hz away. A phase-encoded reference signal is used to calibrate the magnetometers in real time in the presence of interference. Key to the strong interference rejection is the accurate calibration of the reference signal across the array, obtained through electron spin resonance measurements. This calibration is found to be sensitive to atomic polarization, RF pulse duration, and direction of the excitation. The experimental parameters required for an accurate and robust calibration are discussed. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:36 / 46
页数:11
相关论文
共 60 条
[31]   Multi-channel atomic magnetometer for magnetoencephalography: A configuration study [J].
Kim, Kiwoong ;
Begus, Samo ;
Xia, Hui ;
Lee, Seung-Kyun ;
Jazbinsek, Vojko ;
Trontelj, Zvonko ;
Romalis, Michael V. .
NEUROIMAGE, 2014, 89 :143-151
[32]   Effects of nitrogen quenching gas on spin-exchange optical pumping of 3He [J].
Lancor, B. ;
Walker, T. G. .
PHYSICAL REVIEW A, 2010, 82 (04)
[33]   Improved Limits on Spin-Mass Interactions [J].
Lee, Junyi ;
Almasi, Attaallah ;
Romalis, Michael .
PHYSICAL REVIEW LETTERS, 2018, 120 (16)
[34]   Subfemtotesla radio-frequency atomic magnetometer for detection of nuclear quadrupole resonance [J].
Lee, S. -K. ;
Sauer, K. L. ;
Seltzer, S. J. ;
Alem, O. ;
Romalis, M. V. .
APPLIED PHYSICS LETTERS, 2006, 89 (21)
[35]   Ultralow field NMR spectrometer with an atomic magnetometer near room temperature [J].
Liu, Guobin ;
Li, Xiaofeng ;
Sun, Xianping ;
Feng, Jiwen ;
Ye, Chaohui ;
Zhou, Xin .
JOURNAL OF MAGNETIC RESONANCE, 2013, 237 :158-163
[36]  
Livanov M N, 1981, Adv Cardiol, V28, P78
[37]   Chip-scale SERF atomic magnetometer without magnetic shield [J].
Lu, Lin ;
Shang, Jintang ;
Pan, Zhihua ;
Ji, Yu .
2017 IEEE 67TH ELECTRONIC COMPONENTS AND TECHNOLOGY CONFERENCE (ECTC 2017), 2017, :1900-1905
[38]   Revealing dipolar coupling with NQR off-resonant pulsed spin locking [J].
Malone, M. W. ;
McGillvray, M. ;
Sauer, K. L. .
PHYSICAL REVIEW B, 2011, 84 (21)
[39]   MULTIPLE SPIN ECHOES IN PURE QUADRUPOLE-RESONANCE [J].
MARINO, RA ;
KLAINER, SM .
JOURNAL OF CHEMICAL PHYSICS, 1977, 67 (07) :3388-3389
[40]   Explosives detection with nuclear quadrupole resonance - An emerging technology will help to uncover land mines and terrorist bombs [J].
Miller, JB ;
Barrall, GA .
AMERICAN SCIENTIST, 2005, 93 (01) :50-57