CT radiation dose in children: a survey to establish age-based diagnostic reference levels in Switzerland

被引:135
|
作者
Verdun, Francis R. [1 ]
Gutierrez, Daniel
Vader, John Paul [2 ,3 ]
Aroua, Abbas
Alamo-Maestre, Leonor Trinidad
Bochud, Francois
Gudinchet, Francois
机构
[1] CHU Vaudois, Univ Inst Radiat Phys IRA DUMSC, CH-1007 Lausanne, Switzerland
[2] CHU Vaudois, Univ Inst Social & Prevent Med IUMSP DUMSC, CH-1005 Lausanne, Switzerland
[3] Univ Lausanne, CH-1005 Lausanne, Switzerland
关键词
computed tomography; paediatrics; radiation dosimetry; radiation protection; diagnostic reference levels;
D O I
10.1007/s00330-008-0963-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This work aimed at assessing the doses delivered in Switzerland to paediatric patients during computed tomography (CT) examinations of the brain, chest and abdomen, and at establishing diagnostic reference levels (DRLs) for various age groups. Forms were sent to the ten centres performing CT on children, addressing the demographics, the indication and the scanning parameters: number of series, kilovoltage, tube current, rotation time, reconstruction slice thickness and pitch, volume CT dose index (CTDIvol) and dose length product (DLP). Per age group, the proposed DRLs for brain, chest and abdomen are, respectively, in terms of CTDIvol: 20, 30, 40, 60 mGy; 5, 8, 10, 12 mGy; 7, 9, 13, 16 mGy; and in terms of DLP: 270, 420, 560, 1,000 mGy cm; 110, 200, 220, 460 mGy cm; 130, 300, 380, 500 mGy cm. An optimisation process should be initiated to reduce the spread in dose recorded in this study. A major element of this process should be the use of DRLs.
引用
收藏
页码:1980 / 1986
页数:7
相关论文
共 50 条
  • [1] CT radiation dose in children: a survey to establish age-based diagnostic reference levels in Switzerland
    Francis R. Verdun
    Daniel Gutierrez
    John Paul Vader
    Abbas Aroua
    Leonor Trinidad Alamo-Maestre
    François Bochud
    François Gudinchet
    European Radiology, 2008, 18 : 1980 - 1986
  • [2] RADIATION DOSE FOR PEDIATRIC AND YOUNG ADULT CT: A SURVEY TO ESTABLISH AGE-BASED REFERENCE LEVELS OF 2015-2016 IN KOREA
    Kim, MoonChan
    Chang, KwangHyun
    Hwang, JeongHoon
    Nam, YoonChul
    Han, DongKyoon
    Yoon, Joon
    RADIATION PROTECTION DOSIMETRY, 2017, 175 (02) : 228 - 237
  • [3] Age-based diagnostic reference levels and achievable doses for paediatric CT: a survey in Shanghai, China
    Yang, Fanqiaochu
    Gao, Linfeng
    JOURNAL OF RADIOLOGICAL PROTECTION, 2024, 44 (02)
  • [4] Nationwide survey of radiation exposure during pediatric computed tomography examinations and proposal of age-based diagnostic reference levels for Japan
    Takei, Yasutaka
    Miyazaki, Osamu
    Matsubara, Kosuke
    Shimada, Yoshiya
    Muramatsu, Yoshihisa
    Akahane, Keiichi
    Fujii, Keisuke
    Suzuki, Shoichi
    Koshida, Kichiro
    PEDIATRIC RADIOLOGY, 2016, 46 (02) : 280 - 285
  • [5] Nationwide survey of radiation exposure during pediatric computed tomography examinations and proposal of age-based diagnostic reference levels for Japan
    Yasutaka Takei
    Osamu Miyazaki
    Kosuke Matsubara
    Yoshiya Shimada
    Yoshihisa Muramatsu
    Keiichi Akahane
    Keisuke Fujii
    Shoichi Suzuki
    Kichiro Koshida
    Pediatric Radiology, 2016, 46 : 280 - 285
  • [6] A retrospective survey to establish institutional diagnostic reference levels for CT urography examinations based on clinical indications: preliminary results
    Efthymiou, Fotios O.
    Metaxas, Vasileios, I
    Dimitroukas, Christos P.
    Delis, Harry B.
    Zikou, Kiriaki D.
    Ntzanis, Epameinondas S.
    Zampakis, Petros E.
    Panayiotakis, George S.
    Kalogeropoulou, Christina P.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2023, 9 (06)
  • [7] Update of national diagnostic reference levels for adult CT in Switzerland and assessment of radiation dose reduction since 2010
    Aberle, Christoph
    Ryckx, Nick
    Treier, Reto
    Schindera, Sebastian
    EUROPEAN RADIOLOGY, 2020, 30 (03) : 1690 - 1700
  • [8] Update of national diagnostic reference levels for adult CT in Switzerland and assessment of radiation dose reduction since 2010
    Christoph Aberle
    Nick Ryckx
    Reto Treier
    Sebastian Schindera
    European Radiology, 2020, 30 : 1690 - 1700
  • [9] Evaluation of age-based radiation dose in paediatric patients received from head CT examination at a tertiary hospital, Nigeria
    Abdulkadir, Muhammad Kabir
    Izge, Iliyasu Yusuf
    Yunusa, Garba Haruna
    Mohammed, Abacha
    Osman, Noor Diyana
    RADIATION PHYSICS AND CHEMISTRY, 2021, 182
  • [10] Comparison of Anatomical and Indication-Based Diagnostic Reference Levels (DRLs) in Head CT Imaging: Implications for Radiation Dose Management
    Ohene-Botwe, Benard
    Anim-Sampong, Samuel
    Saizi, Robert
    International Journal of Biomedical Imaging, 2025, 2025 (01)