Evaluating water purification at household level in India

被引:6
作者
Aumeier, Benedikt M. [1 ]
Jiang, Xin [1 ]
Djeljadini, Suzana [1 ]
Smeets, Patrick [2 ]
Yuece, Sueleyman [1 ]
Kazner, Christian [3 ]
Wessling, Matthias [1 ,4 ]
机构
[1] Rhein Westfal TH Aachen, Aachener Verfahrenstech, Chair Chem Proc Engn, Forckenbeckstr 51, D-52074 Aachen, Germany
[2] KWR Watercycle Res Inst, POB 1072, NL-3430 BB Nieuwegein, Netherlands
[3] Univ Appl Sci & Arts Northwestern Switzerland, Inst Ecopreneurship, Grundenstr 40, CH-4132 Muttenz, Switzerland
[4] DWI Leibniz Inst Interact Mat, Forckenbeckstr 50, D-52074 Aachen, Germany
关键词
Point of use water purification; Challenge test; Disinfection; Emerging economies; POINT-OF-USE; DRINKING-WATER; FILTRATION; TANZANIA; STRATEGY; STORAGE;
D O I
10.5004/dwt.2017.20802
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Household water treatment systems play an important role in safe drinking water supply in India as safety barrier at point of use and contribute to improved public health on short and medium term. In this study, three household water purifiers that based on different principles were investigated in order to determine whether and under which conditions they can safeguard the microbial safety of drinking water. The water purifiers consisted of the following treatment trains: (i) activated carbon (AC), ultrafiltration (UF) and reverse osmosis, AC and UV irradiation; (ii) AC and UF, and (iii) AC, passive chlorine dosage and AC. They were examined in a two-phase challenge test using bacteria (Escherichia coli) and bacteriophages (MS2) in a laboratory environment. Under normal operation conditions filtering tap water, mean microbial reductions of 4-6 log(10) and 0-3 log(10) for E. coli and MS2 phages, respectively, were observed that therefore partly comply with WHO requirements. Reduction of protozoa (Cryptosporidium oocysts) was estimated based on size exclusion or chlorine exposure to be >= 2 log(10) (membrane-based size exclusion) and < 2 log(10) (chlorine-based disinfection), respectively. To further determine their applicability for filtering water sources with higher pollution load, tap water with increased loads of organic and suspended matter simulating turbid river water (which is beyond the intended use of the systems) was studied. Only the multi-stage treatment was able to remove organics and turbidity to >= 89%. Both tested membrane-based systems suffered from rapid and severe irreversible fouling when challenged with high turbidity whereas the chlorine-based system maintained the production rate, however, at the expenses of a lower physicochemical quality. Hence, none of the tested systems was able to produce water of satisfying physicochemical and microbial quality at sufficient quantities from raw water with turbid river water quality. Therefore, it is suggested introducing mandatory standardized testing protocols and certification of household water purifiers specifying the usage conditions.
引用
收藏
页码:311 / 319
页数:9
相关论文
共 25 条
  • [1] [Anonymous], 2016, RES ROUND 1 WHO INT
  • [2] [Anonymous], 2011, EVALUATING HOUSEHOLD
  • [3] Aumeier B., 2015, 11 AACH TAG WASS AAC, P387
  • [4] Boot M., 1993, Actions Speak: The Study of Hygiene Behavior in Water and Sanitation Projects
  • [5] Cost-effectiveness of water quality interventions for preventing diarrhoeal disease in developing countries
    Clasen, Thomas
    Haller, Laurence
    Walker, Damian
    Bartram, Jamie
    Cairncross, Sandy
    [J]. JOURNAL OF WATER AND HEALTH, 2007, 5 (04) : 599 - 608
  • [6] Laboratory Assessment of a Gravity-Fed Ultrafiltration Water Treatment Device Designed for Household Use in Low-Income Settings
    Clasen, Thomas
    Naranjo, Jaime
    Frauchiger, Daniel
    Gerba, Charles
    [J]. AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2009, 80 (05) : 819 - 823
  • [7] Reduction of cholera in Bangladeshi villages by simple filtration
    Colwell, RR
    Huq, A
    Islam, MS
    Aziz, KMA
    Yunus, M
    Khan, NH
    Mahmud, A
    Sack, RB
    Nair, GB
    Chakraborty, J
    Sack, DA
    Russek-Cohen, E
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (03) : 1051 - 1055
  • [8] Crittenden JC, 2012, Water treatment principles and design 3
  • [9] Reductions of E-coli, echovirus type 12 and bacteriophages in an intermittently operated household-scale slow sand filter
    Elliott, M. A.
    Stauber, C. E.
    Koksal, F.
    DiGiano, F. A.
    Sobsey, M. D.
    [J]. WATER RESEARCH, 2008, 42 (10-11) : 2662 - 2670
  • [10] European Committee for Standardization (CEN), 2014, 930812014 CEN ISO