Diagnostic accuracy of 3-T magnetic resonance imaging with 3D T1 VIBE versus computer tomography in pars stress fracture of the lumbar spine

被引:45
|
作者
Ang, E. C. [1 ]
Robertson, A. F. [1 ]
Malara, F. A. [1 ]
O'Shea, T. [1 ]
Roebert, J. K. [1 ]
Schneider, M. E. [2 ]
Rotstein, A. H. [1 ]
机构
[1] Victoria House Med Imaging, 316 Malvern Rd, Prahran, Vic, Australia
[2] Monash Univ, Fac Med Nursing & Hlth Sci, Dept Med Imaging & Radiat Sci, Monash Biomed Discovery Inst, Clayton, Vic, Australia
关键词
3-TMRI; Three-dimensional T1 VIBE; Pars stress fracture; Pars stress reaction; Lumbar spine; SYMPTOMATIC SPONDYLOLYSIS; BONE-SCINTIGRAPHY; INTERARTICULARIS; MRI; INJURY; SPECT;
D O I
10.1007/s00256-016-2475-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To compare the diagnostic accuracy of 3-T magnetic resonance imaging (MRI) with thin-slice 3D T1 VIBE sequence to 128-slice computer tomography (CT) in pars stress fractures of the lumbar spine. 3-T MRI and CT of 24 patients involving 70 pars interarticularis were retrospectively reviewed by four blinded radiologists. The fracture morphology (complete, incomplete, or normal) was assessed on MRI and CT at different time points. Pars interarticularis bone marrow edema (present or absent) was also evaluated on MRI. In total, 14 complete fractures, 31 incomplete fractures and 25 normal pars were detected by CT. Bone marrow edema was seen in seven of the complete and 25 of the incomplete fractures. The overall sensitivity, specificity and accuracy of MRI in detecting fractures (complete and incomplete) were 97.7, 92.3, and 95.7 %, respectively. MRI was 100 % accurate in detecting complete fractures. For incomplete fractures, the sensitivity, specificity, and accuracy of MRI were 96.7, 92.0, and 94.6 %, respectively. 3-T MRI with thin-slice 3D T1 VIBE is 100 % accurate in diagnosing complete pars fractures and has excellent diagnostic ability in the detection and characterization of incomplete pars stress fractures compared to CT. MRI has the added advantages of detecting bone marrow edema and does not employ ionizing radiation.
引用
收藏
页码:1533 / 1540
页数:8
相关论文
共 50 条
  • [41] Fabrication of a dual T1 and T2 contrast agent for magnetic resonance imaging using cellulose nanocrystals/Fe3O4 nanocomposite
    Torkashvand, Narges
    Sarlak, Nahid
    EUROPEAN POLYMER JOURNAL, 2019, 118 : 128 - 136
  • [42] Optimization of Look-Locker Turbo-Field Echo-Planar Imaging and Evaluation of Its Accuracy in Head and Neck 3D T1 Mapping
    Maehara, Masanori
    Monma, Masahiko
    Nitanai, Takeshi
    Matsumoto, Tetsuya
    Fukuma, Yukiko
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2016, 15 (03) : 288 - 298
  • [43] Evaluation of the orbit using contrast-enhanced radial 3D fat-suppressed T1 weighted gradient echo (Radial-VIBE) sequence
    Bangiyev, Lev
    Raz, Eytan
    Block, Tobias K.
    Hagiwara, Mari
    Wu, Xin
    Yu, Eugene
    Fatterpekar, Girish M.
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1054)
  • [44] Isotropic 3D fast spin-echo imaging versus standard 2D imaging at 3.0 T of the knee—image quality and diagnostic performance
    Oliver Ristow
    Lynne Steinbach
    Gregory Sabo
    Roland Krug
    Markus Huber
    Isabel Rauscher
    Ben Ma
    Thomas M. Link
    European Radiology, 2009, 19 : 1263 - 1272
  • [45] T1 measurement of bound water in cortical bone using 3D adiabatic inversion recovery ultrashort echo time (3D IR-UTE) Cones imaging
    Guo, Tan
    Ma, Yajun
    Jerban, Saeed
    Jang, Hyungseok
    Zhao, Wei
    Chang, Eric Y.
    Chen, Min
    Bydder, Graeme M.
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (02) : 634 - 645
  • [46] Vascular Thoracic Outlet Syndrome: Protocol Design and Diagnostic Value of Contrast-Enhanced 3D MR Angiography and Equilibrium Phase Imaging on 1.5-and 3-T MRI Scanners
    Ersoy, Hale
    Steigner, Michael L.
    Coyner, Karl B.
    Gerhard-Herman, Marie D.
    Rybicki, Frank J.
    Bueno, Raphael
    Nguyen, Louis L.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05) : 1180 - 1187
  • [47] 3D variable-density SPARKLING trajectories for high-resolution T2*-weighted magnetic resonance imaging
    Lazarus, Carole
    Weiss, Pierre
    El Gueddari, Loubna
    Mauconduit, Franck
    Massire, Aurelien
    Ripart, Mathilde
    Vignaud, Alexandre
    Ciuciu, Philippe
    NMR IN BIOMEDICINE, 2020, 33 (09)
  • [48] Magic angle effect on adiabatic T1ρ imaging of the Achilles tendon using 3D ultrashort echo time cones trajectory
    Wu, Mei
    Ma, Yajun
    Wan, Lidi
    Jerban, Saeed
    Jang, Hyungseok
    Chang, Eric Y.
    Du, Jiang
    NMR IN BIOMEDICINE, 2020, 33 (08)
  • [49] Evaluation of vascular variations at cerebellopontine angle by 3D T2WI magnetic-resonance imaging in patients with vertigo
    Celiker, Fatma Beyazal
    Dursun, Engin
    Celiker, Metin
    Durakoglugil, Tugba
    Beyazal, Mehmet
    Inecikli, Mehmet Fatih
    Ozgur, Abdulkadir
    Terzi, Suat
    JOURNAL OF VESTIBULAR RESEARCH-EQUILIBRIUM & ORIENTATION, 2017, 27 (2-3): : 147 - 153
  • [50] Magnetic resonance imaging in the evaluation of cervical foraminal stenosis: comparison of 3D T2 SPACE with sagittal oblique 2D T2 TSE
    Barnaure, I
    Galley, J.
    Fritz, B.
    Sutter, R.
    SKELETAL RADIOLOGY, 2022, 51 (07) : 1453 - 1462