Application of ultrasound microbubble contrast technology in ophthalmic targeted therapy: literature analysis

被引:1
|
作者
Yuan, Jia-Ying [2 ]
Zhang, Jian-Hua [1 ]
Tang, Chong [3 ]
Zhu, Hong [2 ]
Xie, Hua [2 ]
Gao, Shuan-Jie [2 ]
机构
[1] Zhengzhou Univ, Fac Biomed Engn, Zhengzhou 450001, Henan Province, Peoples R China
[2] Directly Hosp Mil Area Henan, Dept Ultrasonog, Zhengzhou 450003, Henan Province, Peoples R China
[3] Xian Elect Hosp, Dept Ultrasonog, Xian 710032, Shaanxi Provinc, Peoples R China
关键词
microbubble contrast technology; targeted therapy; ophthalmic diseases; MEDIATED GENE-TRANSFER; DELIVERY; SAFETY; SONOVUE(TM); EPITHELIUM; AGENT;
D O I
10.3980/j.issn.2222-3959.2011.05.15
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To analyze the application of microbubble contrast technology in the treatment of ophthalmic diseases, mainly analyzing its advantages and existing problems. METHODS: A total of 30 representative literatures about the application of ultrasound contrast agent in gene targeted therapy at home and abroad were collected, and focusing on sorting out the literature reporting the treatment of ophthalmic diseases with microbubble contrast technology in recent years, then recalling its advantages and problems, finally making reasonable assessment on existing problems and proposing possible solutions to the problems. RESULTS: Due to its unique safety and efficacy, the treatment of ophthalmic diseases with microbubble contrast technology has increasingly drawn the attention of clinicians, but two relevant issues should be considered: first, the nature of contrast agent and the choice of corresponding ultrasound parameters; second, relative incidence of tissue bleeding, intravascular hemolysis, moderate or severe allergy as well as other side effects. CONCLUSION: Microbubble may become the carrier of targeted therapy, and as a kind of new non-invasive delivery system, the ultrasound contrast agent has broad application prospects, but its application in ophthalmic research is still in its initial stage and the safety of contrast-enhanced ultrasound still needs further study.
引用
收藏
页码:537 / 542
页数:6
相关论文
共 23 条
  • [21] Early response evaluation of doxorubicin-nanoparticle-microbubble therapy in orthotopic hepatocellular carcinoma rat model using contrast-enhanced ultrasound and intravoxel incoherent motion-diffusion MRI
    Yang, Hyun Kyung
    Kim, Jung Hoon
    Lee, Hak Jong
    Moon, Hyungwon
    Ryu, Hwaseong
    Han, Joon Koo
    ULTRASONOGRAPHY, 2022, 41 (01) : 150 - 163
  • [22] Contrast-Enhanced Ultrasound with VEGFR2-Targeted Microbubbles for Monitoring Regorafenib Therapy Effects in Experimental Colorectal Adenocarcinomas in Rats with DCE-MRI and Immunohistochemical Validation
    Eschbach, Ralf Stefan
    Clevert, Dirk-Andre
    Hirner-Eppeneder, Heidrun
    Ingrisch, Michael
    Moser, Matthias
    Schuster, Jessica
    Tadros, Dina
    Schneider, Moritz
    Kazmierczak, Philipp Maximilian
    Reiser, Maximilian
    Cyran, Clemens C.
    PLOS ONE, 2017, 12 (01):
  • [23] PRE-TRANSPLANTATION OF BONE MARROW MESENCHYMAL STEM CELLS AMPLIFIES THE THERAPEUTIC EFFECT OF ULTRASOUND-TARGETED MICROBUBBLE DESTRUCTION-MEDIATED LOCALIZED COMBINED GENE THERAPY IN POST-MYOCARDIAL INFARCTION HEART FAILURE RATS
    Wang, Wei
    Tayier, Baihetiya
    Guan, Lina
    Yan, Fei
    Mu, Yuming
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2022, 48 (05): : 830 - 845