Agreement of corneal measurements between dual rotating Scheimpflug-Placido system and Placido-based topography device in normal and keratoconus eyes

被引:9
作者
Ortiz-Toquero, Sara [1 ,2 ]
Zuniga, Virginia [2 ]
Rodriguez, Guadalupe [1 ,2 ]
de Juan, Victoria [2 ,3 ]
Martin, Raul [1 ,2 ,4 ]
机构
[1] Univ Valladolid, Dept Fis Teor Atom & Opt, Valladolid, Spain
[2] Univ Valladolid, Sch Optometry, Inst Univ Oftalmobiol Aplicada Eye Inst, Optometry Res Grp, Valladolid, Spain
[3] Ramon y Cajal Univ Hosp, Dept Ophthalmol, Madrid, Spain
[4] Univ Plymouth, Fac Hlth & Human Sci, Plymouth, Devon, England
关键词
FRONT ABERRATION MEASUREMENTS; TOMOGRAPHY; ASTIGMATISM; REPEATABILITY; GALILEI; POWER;
D O I
10.1016/j.jcrs.2016.04.033
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the anterior corneal measurements between Placido-based topography and dual-Scheimpflug topography in healthy and keratoconus eyes. SETTING: Optometry Research Group, Instituto Universitario de Oftalmobiologia Aplicada, University of Valladolid, Valladolid, Spain. DESIGN: Comparative case series. METHODS: The mean simulated keratometry (K), flat K, steep K, astigmatism power, corneal astigmatism axis, JO, J45, maximum corneal power point, and white -to -white (WTW) distance were collected and compared between healthy eyes and keratoconus eyes. RESULTS: The study evaluated in 56 healthy eyes and 56 keratoconus eyes. Placido-based topography underestimated all topographic values except J45 and WTW in healthy eyes and JO, maximum corneal power point, and WTW in keratoconus eyes, with statistically significant differences in astigmatism (healthy), flat K (keratoconus), axis (keratoconus), JO, J45, and WTW (P <.05). Healthy eyes showed better agreement (95% limits of agreement: simulated K -0.13 to 0.40; steep K -0.30 to 0.59; flat K -0.29 to 0.51; astigmatism -0.60 to 0.64; JO -1.15 to 1.13; J45 -1.10 to 1.20; maximum corneal power point -0.70 to 1.17; WTW -0.96 to 0.76 mm) than keratoconic eyes (simulated K -2.84 to 4.55; steep K -2.80 to 5.21; flat K -3.68 to 4.70; astigmatism -1.90 to 2.95; JO -2.85 to 3.20; J45 -3.21 to 3.05; maximum corneal power point -7.00 to 4.51 D; WTW -1.00 to 0.88). CONCLUSIONS: Healthy eyes showed better agreement than keratoconus eyes between Placidobased and dual-Scheimpflug topography. Both instruments could be used interchangeably with caution in healthy eyes, but not in keratoconus management. (C) 2016 ASCRS and ESCRS
引用
收藏
页码:1198 / 1206
页数:9
相关论文
共 23 条
  • [1] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [2] Progression of Keratoconus by Longitudinal Assessment with Corneal Topography
    Choi, Jin A.
    Kim, Man-Soo
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (02) : 927 - 935
  • [3] Agreement Between Placido Topography and Scheimpflug Tomography for Corneal Astigmatism Assessment
    Delrivo, Marianella
    Ruisenor Vazquez, Pablo R.
    David Galletti, Jonatan
    Garibotto, Martin
    Fuentes Bonthoux, Fernando
    Pfoertner, Tomas
    Gaston Galletti, Jeremias
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (01) : 49 - 53
  • [4] Intracorneal rings for keratoconus and keratectasia
    Ertan, Aylin
    Colin, Joseph
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (07) : 1303 - 1314
  • [5] Global Consensus on Keratoconus and Ectatic Diseases
    Gomes, Jose A. P.
    Tan, Donald
    Rapuano, Christopher J.
    Belin, Michael W.
    Ambrosio, Renato, Jr.
    Guell, Jose L.
    Malecaze, Francois
    Nishida, Kohji
    Sangwan, Virender S.
    [J]. CORNEA, 2015, 34 (04) : 359 - 369
  • [6] Comparison of Keratometric Data Obtained by Automated Keratometer, Dicon CT 200, Allegro Topolyzer, and Pentacam
    Gonen, Tansu
    Cosar, Banu
    Sener, Bozkurt
    Keskinbora, Kadircan H.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (08) : 557 - +
  • [7] Repeatability and reproducibility of Galilei measurements in normal keratoconic and postrefractive corneas
    Guler, Emre
    Yagci, Ramazan
    Akyol, Mesut
    Arslanyilmaz, Zeynel
    Balci, Mehmet
    Hepsen, Ibrahim F.
    [J]. CONTACT LENS & ANTERIOR EYE, 2014, 37 (05) : 331 - 336
  • [8] Keratoconus Detection Using Corneal Topography
    Holladay, Jack T.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (10) : S958 - S962
  • [9] Central and Midperipheral Corneal Thickness Measured with Scheimpflug Imaging and Optical Coherence Tomography
    Huang, Jinhai
    Ding, Xixia
    Savini, Giacomo
    Jiang, Zhengxuan
    Pan, Chao
    Hua, Yanjun
    Wu, Fan
    Feng, Yifan
    Yu, Ye
    Wang, Qinmei
    [J]. PLOS ONE, 2014, 9 (05):
  • [10] Three-year follow-up of posterior chamber toric phakic intraocular lens implantation for the correction of high myopic astigmatism in eyes with keratoconus
    Kamiya, Kazutaka
    Shimizu, Kimiya
    Kobashi, Hidenaga
    Igarashi, Akihito
    Komatsu, Mari
    Nakamura, Akio
    Kojima, Takashi
    Nakamura, Tomoaki
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2015, 99 (02) : 177 - 183