Semiautomated Renal Cortex Volumetry in Multislice Computed Tomography: Effect of Slice Thickness and Iterative Reconstruction Algorithms

被引:2
|
作者
Houbois, Christian [1 ]
Haneder, Stefan [1 ]
Merkt, Martin [1 ]
Holz, Jasmin A. [1 ]
Morelli, John [2 ]
Kiel, Alexandra [1 ]
Doerner, Jonas [1 ]
Maintz, David [1 ]
Puesken, Michael [1 ]
机构
[1] Univ Hosp Cologne, Dept Diagnost & Intervent Radiol, Kerpener Str 62, D-50937 Cologne, Germany
[2] St Johns Med Ctr, Tulsa, OK USA
关键词
renal cortex volumetry; split renal function; slice thickness; iterative reconstruction; multislice CT; PULMONARY NODULES; AUTOMATED VOLUMETRY; NUCLEAR-RENOGRAPHY; CT VOLUMETRY; SEGMENTATION; PREDICTION; DONORS;
D O I
10.1097/RCT.0000000000000988
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective The aim of the study was to evaluate the effect of slice thickness, iterative reconstruction (IR) algorithm, and kernel selection on measurement accuracy and interobserver variability for semiautomated renal cortex volumetry (RCV) with multislice computed tomography (CT). Methods Ten patients (62.4 +/- 17.2 years) undergoing abdominal biphasic multislice computed tomography were enrolled in this retrospective study. Computed tomography data sets were reconstructed at 1-, 2-, and 5-mm slice thickness with 2 different IR algorithms (iDose, IMRST) and 2 different kernels (IMRS and IMRR) (Philips, the Netherlands). Two readers independently performed semiautomated RCV for each reconstructed data set to calculate left kidney volume (LKV) and split renal function (SRF). Statistics were calculated using analysis of variance with Geisser-Greenhouse correction, followed by Tukey multiple comparisons post hoc test. Statistical significance was defined as P <= 0.05. Results Semiautomated RCV of 120 data sets (240 kidneys) was successfully performed by both readers. Semiautomated RCV provides comparable results for LKV and SRF with 3 different slice thicknesses, 2 different IR algorithms, and 2 different kernels. Only the 1-mm slice thickness showed significant differences for LKV between IMRR and IMRS (P = 0.02, mean difference = 4.28 bb) and IMRST versus IMRS (P = 0.02, mean difference = 4.68 cm(3)) for reader 2. Interobserver variability was low between both readers irrespective of slice thickness and reconstruction algorithm (0.82 >= P >= 0.99). Conclusions Semiautomated RCV measurements of LKV and SRF are independent of slice thickness, IR algorithm, and kernel selection. These findings suggest that comparisons between studies using different slice thicknesses and reconstruction algorithms for RCV are valid.
引用
收藏
页码:236 / 241
页数:6
相关论文
共 50 条
  • [1] Semiautomated Renal Cortex Volumetry in Spectral Computed Tomography: Effect of Monoenergetic Reconstructions on Measurement Precision and Interobserver Variability
    Houbois, Christian
    Haneder, Stefan
    Merkt, Martin
    Morelli, John
    Weiss, Kilian
    Hellmich, Martin
    Chon, Seung-Hun
    Maintz, David
    Puesken, Michael
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (01) : 138 - 144
  • [2] Effect of varying slice thickness on coronary calcium scoring with multislice computed tomography in vitro and in vivo
    Mühlenbruch, G
    Thomas, C
    Wildberger, JE
    Koos, R
    Das, M
    Hohl, C
    Katoh, M
    Günther, RW
    Mahnken, AH
    INVESTIGATIVE RADIOLOGY, 2005, 40 (11) : 695 - 699
  • [3] Dose-optimized slice thickness for routine multislice computed tomography liver examinations
    Dobeli, K.
    Lewis, S.
    Meikle, S.
    Thiele, D.
    Brennan, P. C.
    MEDICAL IMAGING 2012: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2012, 8318
  • [4] ITERATIVE CONCURRENT RECONSTRUCTION ALGORITHMS FOR EMISSION COMPUTED-TOMOGRAPHY
    BROWN, JK
    HASEGAWA, BH
    LANG, TF
    PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (07): : 1113 - 1132
  • [5] Computed tomography system performance for different iterative reconstruction algorithms
    Findikli, I.
    Yalcin, A.
    Kasapgil, O.
    Yildirim, B.
    Fitoz, S.
    Onur, M. R.
    Boyunaga, O. L.
    Atac, G. K.
    Sancak, T.
    Olgar, T.
    RADIATION PHYSICS AND CHEMISTRY, 2024, 222
  • [6] Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness
    Fischbach, F
    Knollmann, F
    Griesshaber, V
    Freund, T
    Akkol, E
    Felix, R
    EUROPEAN RADIOLOGY, 2003, 13 (10) : 2378 - 2383
  • [7] Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness
    Frank Fischbach
    Friedrich Knollmann
    Volker Griesshaber
    Torsten Freund
    Ethem Akkol
    Roland Felix
    European Radiology, 2003, 13 : 2378 - 2383
  • [8] The prediction of postoperative renal function from renal cortex volumetry with preoperative multidetector computed tomography
    Isotani, Shuji
    Shimoyama, Hiroshi
    Noma, Yasuhiro
    Saito, Keisuke
    Muto, Satoru
    Ide, Hisamitsu
    Yamaguchi, Raizo
    Horie, Shigeo
    CANCER RESEARCH, 2014, 74 (19)
  • [9] Monotonic iterative reconstruction algorithms for targeted reconstruction in emission and transmission computed tomography
    La Riviere, Patrick J.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2924 - 2928
  • [10] Computed tomography liver volumetry in living donor liver transplantation: influence of the slice thickness on the volume calculation
    Fatima, Tooba
    Rafique, Muhammad Salman
    Kundi, Sana
    Malik, Tahir
    Ijaz, Faryal
    Zulfiqar, Sahar