EFFECTS OF INCREASING BLADE HUB LOADING ON INSTABILITY EVOLUTION IN A LOW-SPEED COMPRESSOR

被引:0
|
作者
Li, Qiushi [1 ]
Li, Simin [1 ]
Pan, Tianyu [1 ,3 ]
Arshad, Ali [1 ]
Gong, Yifang [2 ]
机构
[1] Beihang Univ, Natl Key Lab Sci & Technol Aeroengine Aerothermod, Sch Energy & Power Engn, Beijing, Peoples R China
[2] Anhui KEDA Air Compressor, Hefei, Anhui, Peoples R China
[3] Duke Univ, Dept Mech Engn, Durham, NC 27708 USA
来源
PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2017, VOL 2D | 2017年
基金
中国国家自然科学基金;
关键词
STALL INCEPTION; ROTATING STALL; AXIAL COMPRESSORS;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Based on previous results showing that a compressor stall can be initiated from hub region, a hypothesis is further proposed: the type of stall inceptions is related to the loading distributions. A series of experiments are designed to examine the effects of radial loading to the stall inception and its evolution. Well-designed distortion screens installed at the inlet of a single-stagelow-speed axial compressor induce various radial distributions of blade loading. The uniform inflow situation, i.e. without screen, is defined as the baseline, in which case the compressor shows the modal type stall inception. With hub distortion screens, the hub loading is keeping to be increased, however, the compressor still shows modal type of stall inception. After further data processing, it is found that there is a period between linear growth of modal wave and the formation of a large amplitude stall cell. In that period, the tip pressure signal does not show any clear traveling disturbances. In further investigation, it is found that there are large disturbances formed in the hub region during this period. With increasing the hub loading, the large amplitude disturbances in hub region appear earlier and earlier. In our previous work, the compressor showed spike type stall inception with a tip distortion screen. Combining these observations, it is proposed that radial loading of the blade does have significant effects on both the type of stall inception and the evolution which is in particular corresponding to transient process from small linear disturbance to final formation of stall cell in our compressor.
引用
收藏
页数:9
相关论文
共 26 条
  • [21] Pressure oscillations in a single stage axial-flow low-speed compressor during pre-stall and stall
    Levy, Y.
    Pismenny, J.
    Deppe, A.
    Saathoff, H.
    Schrapp, H.
    Stark, U.
    INTERNATIONAL JOURNAL OF TURBO & JET-ENGINES, 2007, 24 (01) : 29 - 50
  • [22] Investigation of Vaned-Recessed Casing Treatment in a Low-Speed Axial-Flow Compressor, Part II: Unsteady Results
    Akhlaghi, Mohammad
    Azizi, Yahya
    AEROSPACE, 2023, 10 (09)
  • [23] Tip leakage flow, tip aerodynamic loading and rotating instability in a subsonic high-speed axial flow compressor rotor
    Chen, Zhiyang
    Wu, Yanhui
    An, Guangyao
    AEROSPACE SCIENCE AND TECHNOLOGY, 2021, 110
  • [24] Investigation of Vaned-Recessed Casing Treatment in a Low-Speed Axial Flow Compressor, Part I: Time-Averaged Results
    Akhlaghi, Mohammad
    Azizi, Yahya
    AEROSPACE, 2023, 10 (09)
  • [25] AN EXPERIMENTAL INVESTIGATION OF THE NON-AXISYMMETRIC CASING TREATMENT FOR A LOW-SPEED AXIAL-FLOW COMPRESSOR UNDER CIRCUMFERENTIAL INFLOW DISTORTION
    Zhao, Pan
    Zhang, Min
    Li, Yihan
    Xu, Xiaobin
    Ba, Dun
    Du, Juan
    PROCEEDINGS OF ASME TURBO EXPO 2024: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, GT2024, VOL 12A, 2024,
  • [26] Experimental analysis of the influence of outlet network volume and inlet guide vane positioning on surge behavior in a single-stage low-speed centrifugal compressor
    Kabalyk, Kirill
    Jasek, Michal
    Liskiewicz, Grzegorz
    Horodko, Longin
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2018, 232 (04) : 350 - 363