Particulate matter in air at indoor go-kart facilities in Bavaria, Germany

被引:4
作者
Sysoltseva, Marina [1 ]
Winterhalter, Richard [1 ]
Wolf, Janine [1 ]
Berlin, Knut [1 ]
Eckert, Saskia [1 ]
Fembacher, Ludwig [1 ]
Matzen, Wolfang [1 ]
Nitschke, Lutz [1 ]
Scheu, Christina [2 ,3 ]
Fromme, Hermann [1 ,4 ]
机构
[1] Bavarian Hlth & Food Safety Author, Dept Chem Safety & Toxicol, Pfarrstr 3, D-80538 Munich, Germany
[2] Max Planck Inst Eisenforsch GmbH, Max Planck Str 1, D-40237 Dusseldorf, Germany
[3] Rhein Westfal TH Aachen, Mat Analyt, Kopernikusstr 10, D-52074 Aachen, Germany
[4] Ludwig Maximilians Univ Munchen, Inst & Outpatient Clin Occupat Social & Environm, Ziemssenstr 1, D-80336 Munich, Germany
关键词
Go-kart; Particulate matter; Emission; Soot; Brake abrasion; Indoor air pollution; EMISSION FACTORS; EXPOSURE; PM2.5; POLLUTION; VEHICLES;
D O I
10.1016/j.atmosenv.2018.09.010
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Indoor go-karting is a popular free time activity for many people, including adults and children. Particulate matter from engine emissions, brake and tire debris and gaseous pollutants are important sources of air pollution. Exposure to these air pollutants is associated with health-related problems. In this study, the exposure of employees and spectators to particulate matter was measured in 8 indoor go-kart facilities (6 facilities used gasoline, one used liquid gas and one used electricity for their go-karts). The mass concentrations of particulate matter were continuously analyzed. Particles were sampled and analyzed by inductively coupled plasma mass spectrometry and electron microscopy coupled with energy-dispersive X-ray spectroscopy. The mean PM10 concentrations ranged between 4.9 and 34.9 mu g/m(3) for workplaces and 5.6 and 28.4 mu g/m(5) for spectator areas. The mean PM2.5 concentrations measured in workplaces ranged from 2.3 to 29.2 mu g/m(3) and from 2.4 to 27.4 mu g/m(3) in the spectator areas. The highest PM10 and PM2.5 concentrations were measured at the liquid gas go-kart facility and at go-kart facilities with the maximum number of go-karts running simultaneously. The electric go-kart facility showed high PM10 concentrations but low PM2.5 values. The highest particle number concentration was measured in the workplace of the facility using liquid gas go-karts (2.7 x 10(5) particles/cm(3)), and the lowest concentration at both measurement points of the electrical go-kart facility (1.8 x 10(4) particles/cm(3)). Metals such as copper, zinc, strontium, barium, aluminum, calcium, manganese, iron and nickel were found in nearly all samples with help of inductively coupled plasma mass spectrometry. The most abundant metal was iron, with concentrations up to 5.6 mu g/m(3) (electric go-kart facility). Electron microscopic investigations showed high concentrations of soot in all samples, except for the samples of the electric go-kart facility. Additionally, agglomerates with iron and other metals were found in all samples. To summarize, electric go-karts, combined with a good ventilation system, seem to be more suitable for indoor use.
引用
收藏
页码:118 / 126
页数:9
相关论文
共 22 条
  • [11] PM2.5 and CO Concentrations Inside an Indoor Go-Kart Facility
    Kim, Thomas
    Wagner, Jeff
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2010, 7 (07) : 397 - 406
  • [12] Air Pollution from Road Traffic and Systemic Inflammation in Adults: A Cross-Sectional Analysis in the European ESCAPE Project
    Lanki, Timo
    Hampel, Regina
    Tiittanen, Pekka
    Andrich, Silke
    Beelen, Rob
    Brunekreef, Bert
    Dratva, Julia
    De Faire, Ulf
    Fuks, Kateryna B.
    Hoffmann, Barbara
    Imboden, Medea
    Jousilahti, Pekka
    Koenig, Wolfgang
    Mahabadi, Amir A.
    Kuenzli, Nino
    Pedersen, Nancy L.
    Penell, Johanna
    Pershagen, Goran
    Probst-Hensch, Nicole M.
    Schaffner, Emmanuel
    Schindler, Christian
    Sugiri, Dorothea
    Swart, Wim J. R.
    Tsai, Ming-Yi
    Turunen, Anu W.
    Weinmayr, Gudrun
    Wolf, Kathrin
    Yli-Tuomi, Tarja
    Peters, Annette
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 2015, 123 (08) : 785 - 791
  • [13] LFU, 2016, BAV ENV AG TAG FEINS
  • [14] LFU, 2017, BAV ENV AG TAG FEINS
  • [15] Short-term exposure to particulate air pollution and risk of myocardial infarction: a systematic review and meta-analysis
    Luo, Chunmiao
    Zhu, Xiaoxia
    Yao, Cijiang
    Hou, Lijuan
    Zhang, Jian
    Cao, Jiyu
    Wang, Ailing
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2015, 22 (19) : 14651 - 14662
  • [16] On-road emissions of particulate polycyclic aromatic hydrocarbons and black carbon from gasoline and diesel vehicles
    Miguel, AH
    Kirchstetter, TW
    Harley, RA
    Hering, SV
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1998, 32 (04) : 450 - 455
  • [17] Quantification of particle number emission factors for motor vehicles from on-road measurements
    Morawska, L
    Jamriska, M
    Thomas, S
    Ferreira, L
    Mengersen, K
    Wraith, D
    McGregor, F
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (23) : 9130 - 9139
  • [18] Day-of-week patterns of particulate matter and its chemical components at selected sites in California
    Motallebi, N
    Tran, H
    Croes, BE
    Larsen, LC
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2003, 53 (07) : 876 - 888
  • [19] Wolf J., 2018, INDOOR AIR UNPUB
  • [20] Long-term particulate matter exposure: Attributing health effects to individual PM components
    Wyzga, R. E.
    Rohr, A. C.
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2015, 65 (05) : 523 - 543